1 Disclaimer The A3 motion simulator (the system) is capable of moving the user very rapidly and sharply and is therefore potentially dangerous for use by those with conditions including but not limited to spinal / neck injuries / weaknesses, epilepsy, motion sickness, vibration injuries / susceptibility and any other condition which makes the user adversely affected by sudden movements &...
3.1. Seat Installation & Adjustment Remove the Atomic A3 base unit from its packaging and situate it on a level, stable operating surface for intended use. WARNING: Never lift the base unit by the plastic housing, or damage may result to the mounts (the housing is ‘floating’...
If further tightening is required, press and hold the red button on the lever (disengaging it from the tightening mechanism), turn anti-clockwise, release the button and further tighten clockwise. A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
Slide the foot rest towards or away from the seat as required (ensuring that it is always seated within the clamps shown above) and secure in place by tightening the adjustment knob (clockwise). A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
(Height Adjustment section). Note: The steering wheel / yoke mount mechanism is reversible to facilitate both left and right hand drive layouts – please contact AMS for further instruction if required. A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
Loosen the adjustment knob shown on the right by turning anti-clockwise. Slide the wheel / yoke mount top-assembly higher or lower as required and secure in place by tightening the adjustment knob (clockwise). A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
(relative to the motion base) using the indexing holes provided, and replace / tighten the thumb screws. NB The side mount can be located on either the left or right of the motion base. A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
Note: In situations where many users will be riding (e.g. commercial settings), it is recommended the COG is configured for an average height user within the group to obtain the best results. A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
Connect the supplied IEC Mains lead to the Power port ((3) IEC Input), and the other end to any available mains socket. The acceptable input voltage range is universally compatible with all standard mains power supply systems ( 100-240VAC, 50/60Hz). A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
If this does not happen, please read the Safety Interlock System instructions below. You can also refer to Appendix C - Troubleshooting. A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
‘safety interlock’, and this condition will be highlighted by the red LED next to the emergency stop button (the ‘Atomic’ logo will also turn red). NOTE: pressing the emergency stop button quickly will lock the actuators in their place, pressing and holding for longer than 4 seconds will disconnect power to the actuators (and amplifier in a TTi-equipped unit) completely to allow safe removal of any trapped object.
11 Driver Software Installation The Atomic can be controlled using either a PC (via Actuate Motion software or similar), or DMX capable controller (refer to Appendix B – DMX Network Setup). 11.1. Actuate Motion A license to the Actuate Motion software is granted with your simulator. If you have not already received your license and download instructions, contact support@actuate-motion.com...
If you have a TTi unit, ensure your line level input (connected to the Audio IN port on the Atomic) has a strong signal and the volume output on your computer is set to maximum for the best results.
14 Appendix A - Device Firmware Update (DFU) From time to time it may be necessary to update the firmware of your Atomic system as AMS introduce additional functionality. This is done via the AMS DFU (Device Firmware Updater), which is a software utility available freely from AMS for your Windows-compatible PC.
If you are unsure about DMX channel setup or will only be using a single motion system via PC control, just set the unit to channel 1 by enabling switch 1 (on) and disabling all others (off). A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
It is recommended the command channel is set to the desired value for a minimum of 0.5 seconds before being reverted back to zero, to ensure the command is transmitted correctly A3 Motion Simulators, Assembly & Instruction Manual, November 2018...
• Disengage the safety interlock by pressing the black ON button No motion, activated (LED on (marked ‘1’). actuators • If the red LED / ‘Atomic’ logo remains illuminated, check the switch panel and locked in place ‘Atomic’ logo will base plastic cover is free from obstruction and not pressing be illuminated red).
Need help?
Do you have a question about the A3 and is the answer not in the manual?
Questions and answers