National Semiconductor LM1830 Application Brief

Fluid level control application brief 10 systems

Advertisement

Quick Links

Fluid Level Control
Systems Utilizing
the LM1830
Abstract The LM1830 fluid level detector is a device in-
tended to signal the presence or absence of aqueous solu-
tions This application brief shows how to implement HIGH
LOW limit control applications utilizing this device
Many opportunities exist for a device that can reliably con-
trol the operation of pumps or solenoid actuated valves in
fluid level control applications Applications include sump
pumps bilge pumps washing machines humidifiers plating
baths continuous replenishment photographic processors
coffee makers municipal water and waste treatment plants
cooling towers refrigeration equipment and others
Classically these needs have been met by various mechan-
ical arrangements such as float valves or diaphragm actuat-
ed switches These devices are bulky inaccurate and be-
cause they contain moving parts unreliable often with di-
sastrous results when they fail They are easily disabled by
debris or environmental problems such as ice They can be
expensive when used to control the level of corrosive fluids
such as plating baths or detergents or when used to control
large differences in depth such as in municipal water tow-
ers Mechanical control devices are prone to false actuation
in vehicular applications (such as bilge pump controls) due
to their own inertia In many applications such as coffee
makers they are too bulky to fit within the confines of the
package By utilizing electronic means based on the
LM1830 problems inherent in mechanical solutions are
overcome and a reliable cost effective approach to fluid
level control is made possible
The LM1830 is a monolithic bipolar integrated circuit de-
signed to detect the presence or absence of aqueous fluids
An AC signal generated on-chip is passed through two
probes within the fluid A detector determines the presence
of the fluid by using the probes in a voltage divider circuit
and measuring the signal level across the probes An AC
signal is used to prevent plating or dissolving of the probes
as occurs when a DC signal is used A pin is available for
connecting an external resistance in cases where the fluid
impedance is not compatible with the internal 13 kX divider
resistance
The addition of a CD4016 quad CMOS analog switch (Fig-
ure 1) allows the LM1830 to be used for HIGH LOW limit
control applications The switch sections are opened and
closed by a control signal where a HIGH level turns the
switch ON and a LOW level turns the switch OFF Ground-
ing the input of one switch section and pulling its output up
with a resistor creates an inverter Probes are connected to
the inputs of two of the remaining analog switches Their
outputs are connected to pin 10 of the LM1830
C 1995 National Semiconductor Corporation
TL H 5071
National Semiconductor
Application Brief 10
which is the detector input The remaining section of the
CD4016 is used to buffer the open collector output of the
LM1830 All of the control inputs of the quad analog switch
are tied to this output The last switch section controls the
base of a transistor which in turn drives a relay or solenoid
actuated valve
The start and stop probes are set at their appropriate levels
in the fluid container and the ground return is connected to
a third probe located at a depth greater than the start and
stop probes If the container is conductive it may be used
as the ground return Let's assume we have a situation
where we wish to empty the container when fluid reaches a
predetermined level sump or bilge pump Figure 1(a) With
no fluid covering either of the probes pin 12 of the LM1830
switches LOW This disables the relay and enables the ana-
log switch connected to the start probe Fluid eventually fills
the container covering the start probe When this occurs
the output of the LM1830 switches HIGH and the pump
relay is enabled thereby draining the container At the same
time the analog switch used as an inverter enables the ana-
log switch connected to the stop probe and disables the
start probe Draining continues until the stop probe is above
the level of fluid in the container Then the output of the
LM1830 switches LOW disabling the relay (halting the drain
operation) and switching the start probe back to its active
state
By reversing the labeling on the probes as well as reversing
the polarity of the relay drive a container ''fill'' control is
implemented such as would be used in a water tower Nec-
essary circuit changes are shown in Figure 1(b)
A pump control for a waste water holding tank in a photo-
graphic darkroom has been implemented with this circuitry
This replaced a float actuated system which failed consist-
ently due to the corrosive nature of the chemicals used in
photographic processing With one year of continuous serv-
ice no failures have occurred in this system Furthermore
there is no evidence of plating on the sense electrodes in
spite of the fact that the waste water is loaded with silver
ions A plastic holding tank is used with stainless steel bolts
inserted through holes drilled in the tank as sense probes
(Figure 2) A solid-state relay controls a
to empty the tank
Obviously careful selection of probe materials must be
made to maximize reliability with this system Excellent
sources of information on materials in corrosive environ-
ments are available in publications such as Omega's Tem-
perature Measurement Handbook or Eastman Kodak's
Darkroom Design Manual
HP pump motor
RRD-B30M115 Printed in U S A