Falco Systems WMA-IB-HS User Manual

20mhz high speed phase inverter - buffer

Advertisement

Quick Links

Falco Systems WMA-IB-HS
● Double the output voltage by driving 2 high voltage amplifiers in bridge
mode
● Switchable 50Ω /100kΩ input: buffer low-current signal sources to drive
high-speed 50Ω amplifier inputs
● High speed: DC – 20MHz @ -3dB full power bandwidth
● ±10V maximum output voltage
About this manual
This user manual is an integral part of the
Falco Systems WMA-IB-HS phase inverter
- buffer product. Please read it carefully
and pay attention to the recommendations
and instructions for safe use.
Operation of the phase inverter
The WMA-IB-HS is a low noise, high
speed DC - 20MHz phase inverter - buffer
designed to drive one or two high voltage
amplifiers. It can be used:
Ÿ To drive two amplifiers in bridge mode
by using both the buffered output and the
inverting output, or
Ÿ As a high impedance buffer between a
signal source and the amplifier
The input of the WMA-IB-HS is switchable
to 100kΩ input impedance and to 50Ω:
Ÿ The 50Ω setting is used with 50Ω
sources such as function- or arbitrary
waveform generators, to ensure waveform
20MHz High Speed Phase Inverter - Buffer
USER MANUAL
integrity
frequencies.
Ÿ The 100kΩ setting is used to buffer
current limited signal sources such as
typical computer controlled DAQ (data
acquisition) cards.
Internal gain switching circuitry makes
sure that the output signal amplitude does
not change with the setting of the switch
when the input impedance switch is
toggled (when driven from a 50Ω source).
The outputs of the WMA-IB-HS can drive
both high impedance and 50Ω high
voltage amplifier inputs. The WMA-IB-HS
can also be used as a high quality stand-
alone phase inverter - buffer in a variety of
other applications.
The WMA-IB-HS ships with a customized
Mean Well GS25B28-P1J power supply.
The power supply connector, 315mAT
fuse and on-off switch are on the rear
panel of the WMA-IB-HS enclosure. A blue
led indicates that the WMA-IB-HS is on.
even
at
high
operating

Advertisement

Table of Contents
loading

Summary of Contents for Falco Systems WMA-IB-HS

  • Page 1 Operation of the phase inverter when the input impedance switch is toggled (when driven from a 50Ω source). The WMA-IB-HS is a low noise, high speed DC - 20MHz phase inverter - buffer The outputs of the WMA-IB-HS can drive designed to drive one or two high voltage both high impedance and 50Ω...
  • Page 2: Bridge Mode

    When two amplifiers are driven in bridge mode, the high voltage output signal with twice the amplitude of the individual high The WMA-IB-HS can be used to double voltage amplifiers is available between the the maximum output voltage driving a...
  • Page 3 Fig. 5. Required amplifier properties Cable Cable inner The WMA-IB-HS phase inverter - buffer conductor can be used with many high voltage Cable outer Load amplifiers, and is not limited to driving shield amplifiers of the Falco Systems brand.
  • Page 4: Buffer Mode

    50Ω impedance 50Ω 50Ω The input of the WMA-IB-HS is set to the Vout = Vin/2 high impedance 100kΩ setting not to load the signal source unduly, and its ‘buffered 100kΩ...
  • Page 5: Recommendations And Safety

    Figure 8g. 0Ω generator, 50Ω input, high connector. impedance load; Vout = 2·Vin Ÿ The airflow to and from the WMA-IB-HS should not be blocked or impeded, to allow Figure 8. The gain structure of the WMA- for adequate ventilation.
  • Page 6 9a. Input signal (divided by 2 due to the 50Ω loading of the 50Ω output of the generator by the 50Ω input of the WMA-IB-HS) Time (μs) 9b. Buffered output signal: signal amplitude is restored by the 2x gain of the WMA-IB-HS Time (μs) 9c. Corresponding inverted output signal Figure 9.
  • Page 7 50 Ohm input 100k input Frequency (Hz) Figure 10. Bandwidth at 3Vpp into a 50Ω load with the input switched to 50Ω and 100kΩ input impedance (the 100kΩ response depends on type of source and input cable properties) -200 -400 -600 Time (ms) 11a.
  • Page 8: Technical Specifications

    Power: 28V DC, 200mA maximum, with 315mAT 5x20mm 230V fuse and on/off switch on rear panel. Use the power supply adapter supplied by Falco Systems only: Mean Well GS25B28-P1J, 100-240V~ 50/60Hz in, 28V 0.75A DC out, 25W, with custom MiniDIN...
  • Page 9 User manual version User manual version: 1.5 Date: October 29, 2018 Falco Systems Falco Systems Remisestraat 1 2225 TH Katwijk aan Zee The Netherlands Tel. +31 (0)6 21840996 Fax. +31 (0)20 2031445 Email: info@falco-systems.com www.falco-systems.com...

Table of Contents