DUCATI
General installation diagram
8
4
3
1
5
9
A
2
B
9
A= junction box
B= safety power switch
Mechanical end stops (limits)
It is mandatory that your gate has mechanical limits fixed on the ground.
The limits must stop the gate wings in the closed and open position of each wing. Your gate must be
provided with mechanical end stops to be automated. The end sops on the floor can only be omissed
in case of gate opener supplied with integrated limits (FC versions).
Ducati's gate openers are conceived to stop by amperometric detection. When the gate wing touches
and pushes on the mechanical limit (end stop), an amperometrical increase is detected by the control
board and motor stops. An imperceptible drive reversal draws pressure from the gears of the engine
to preserve its life
Warning: make sure not to use the full actuator stroke as the gate wing must stop by pressing
on a mechanical end limit (fixed on the ground or FC onboard limit) before the actuator rea-
ches the end of it's stroke.
Warning: if you purchased an FC version actuator, check whether the integrated limit can be used for
the open or closed gate position: in fact, not all FC-actuators have double end travel for both positions
gate open + gate closed. The use of the integrated travel limit also depends on the opening direction
of the gate ( push-to-open or pull-to-open).
8
L
6
15 cm
min.
1= Control box with containing electronic
board with on board radio receiver,
toroidal transformer, integrated battery
housing compartment.
2 = actuators
3 = blinking light
4 = external antenna (if supplied)
7
5 = key switch
9
6 = radio remote control
7 = radio keypad (if supplied)
8 = solar panel (if supplied)
9 = pair of photocells (if supplied)
2
L= wing lenght
WARNING: angle of incidence
9
To ensure a perfect lock of the gate when
closed, the actuator must be installed in way
to have an angle of incidence to the gate
wing in closed position.a greater angle ensu-
res greater tightness
2°= M2
1°= M1
(Gate that
opens first)
Mechanical end stops
(limit) to be fixed on the
ground
GATE
Angle
Example of End
stop limit to be
15 cm
fixed on the
min.
ground

Advertisement

Table of Contents
loading

Summary of Contents for Ducati SW400

  • Page 1 (FC versions). res greater tightness Ducati’s gate openers are conceived to stop by amperometric detection. When the gate wing touches and pushes on the mechanical limit (end stop), an amperometrical increase is detected by the control board and motor stops.
  • Page 2 DUCATI General installation diagram: mechanical limits & pillar dimension PULL TO OPEN OPERATION (gate that opens towards inside) This means the gate operator is mounted on the inside of the property and pulls your gate in towards the property to open.
  • Page 3: Metric Conversion

    PULL TO OPEN OPERATION ( opens towards inside) SW400 SW400 FC (with on board open & closed This means the gate operator is mounted on the inside of the property position mechanical limits) and pulls your gate in towards the property to open.
  • Page 4 DUCATI SW / EVO actuators: Specific drawings EVO LOCK: optional manual release protection by key STANDARD manual release Mechanical limits (only available on LIMIT POINT LIMIT POINT “FC”versions)
  • Page 5: Safety Warnings

    Ducati’s electromechanical actuators are provided with DC motor, worm screw could cause severe injury and/or death, for which the manufacturer cannot be held gear. The motor must be run by a compatible original “DUCATI HOME automation” responsible. control unit only.
  • Page 6 DUCATI Preliminary safety warnings and important informations - High voltage wiring (110V-230V power) must be done exclusively by a competent • Before starting the installation, check whether the product is suitable to automate professional and certified electrician. your gate, If it is not suitable, DO NOT proceed with the installation.
  • Page 7: Mounting Hardware

    EN norms. adjustable wrench; DUCATI ensure that the forces generated by a correctly installed gate opener, when outdoor electric cable ( 2 poles) H07NRF length according to the connection of the touching a person or an obstacle are limited and that they do not exceed the values two actuators to the control box;...
  • Page 8 DUCATI How to install the actuator The control unit box must be placed outside the reach of children and unauthorized specific actuator diagram (page10-22) to verify it is compatible for installation on persons, (at a suggested high of min. 1,2 m from the ground) preferably with a gate that opens towards outside.
  • Page 9 DUCATI How to install the actuator Warning: on double wing gates use same A & B measure on both sides. actuator’s model see diagram on page HC 312........page 10 To determine the most suitable mounting position, proceed as follows: HC 412........page 11 - Measure the depth of the the Post/ pillar column where your gate is installed to HC 512........page 12...
  • Page 10: Manual Release

    Resume of NON telescopic actuators models: accessory is also available. see page 23 fig. 15B HC418; HC518,HC618, SW400; EVO900; EVE900 (+ corresponding 24V versions) For “SW & EVO acuators the optional “ SW LOCK” manual release key protected accessory is also available. see page 25 fig.26B...
  • Page 11: Maintenance

    DUCATI DUCATI How to install the actuator HOW TO ADJUST THE INTEGRATED END LIMIT ( FC VERSIONS ONLY) 6. Control maneuver. Test of correct mechanical installation of the actuators on the gate 7.1 on board mechanical limits adjustment ( for FC actuator’s versions only)