Warnings • Read the safety and operating instructions before using any Spartan Tool product . Drain and sewer cleaning can be dangerous if proper procedures are not followed and appropriate safety gear is not utilized . Read the engine owners’ manual for instructions and safety precautions on engine operation .
Features SPECS • Pipe Sizes: up to 18" diameter • Max Water Pressure: 3,000 psi • Max Water Flow: 19 GPM • Water Capacity: 160 gallons • Unit Weight: 1,200 lbs (empty) • Overall Size: 523/4"L x 49"W x 499/16"H •...
Description—Controls ECONTROLLER FUNCTIONS Spartan Tool provides several options on the Urban Warrior skid mount sewer jetter . As a result, there are multiple eControl configurations to accommodate the features available on any particular unit . This section of the manual will cover available functions of the Two Function eController and the Three Function eController .
Description—Controls CORONA DISPLAY The Corona on the eController is normally off (gray) . Blue Orange corona indicates corona indicates corona indicates set to Riomote Control eController error pre-start functions or one of two error conditions: See page 27 (eController Errors) for alarm functions •...
Description—Controls NAVIGATION BULLETS The navigation bullets have two general states: Passive (gray) Active (blue) Depending on the user’s location in the menu, one bullet is on display, or in the case of a pop-up eController error, all navigation bullets disappear . (See page 27, eController Errors, for a list of pop-up displays.) Features in navigation bullets are in specified order, if applicable: Home Management...
Description—Controls Hose Counter (if equipped) When the eController is set to Hose Counter mode, the LCD displays a menu of two functions that can be selected by rotating the Navigator dial and activated by depressing the navigation knob . • Hose Counter allows the user to select on or off . •...
Description—Controls REMOTE CONTROL Hand-Held Remote Sender Emergency stop Hose UP/DOWN (9-channel option) Engine speed SLOW Engine speed FAST Spray valve OFF Spray valve ON Engine OFF Engine START Battery indication Remote pairing The Riomote® radio remote control consists of a large waterproof and shockproof hand-held sender and a unit-mounted receiver .
• Ensure there are no combustible materials in the area . • The area must be adequately ventilated to prevent accumulation of carbon monoxide . • DO NOT use corrosive chemicals in conjunction with Spartan Tool sewer jetters . Only environmentally-approved chemicals should be introduced into drain lines .
Page 17
Safety Instructions GENERAL PRECAUTIONS • Do not let the machine operate without supervision . • Keep children and animals away from the machine . • DO NOT spray on humans or animals . If the skin is penetrated, immediately seek medical attention. •...
The mechanical relief in the unloader valve will prevent pressure from exceeding 3000 PSI. WARNING If the unit fails to maintain pressure within the operating zone, contact Spartan Tool Customer Service at 800 .435 .3866 or by email at CustomerService@SpartanTool .com .
Mechanical Operation CHECK BEFORE DEPARTURE Before you drive away with the vehicle, check the following: The high-pressure hose has been inserted into the hose holder (5) and secured with the locking pin . The high-pressure hose reel is locked with the clutch engaged (30) (see page 21) and the manual hydraulic hose reel control lever is in the neutral position, or the eController is not in Hose Reel mode .
Mechanical Operation STARTING THE ENGINE IMPORTANT! The machine is equipped with an Emergency Stop . By operating this Stop, the machine will shut down . Do not use this button for normal stopping . Only use when dangerous situations occur . After use, rotate the Emergency Stop clockwise to be able to start again .
Mechanical Operation If the error icon is not visible, depress the Engine On button for two seconds . • After 5 seconds, the engine starts . • With the engine running, the blue Engine LED light (38) and the Engine On light (39) is displayed for 2 seconds .
Mechanical Operation HYDRAULIC REEL CONTROL (if equipped) The hydraulic control lever is spring loaded to default to the Neutral Position (A) where the hose reel is locked by the hydraulic actuator . • Pushing the control lever up (position B) will actuate the hydraulic motor to wind the hose onto the reel .
eController Operation MANAGEMENT MODE Management Mode functions to display the current software version, required service intervals, and the hose reel counter . Rotate the Navigator dial to set the navigation bullet to the last position, Management . Depress the Navigator dial to activate the Management function . •...
NOTE! The engine will shut down if the remote is Battery Start indicator out of range or the battery loses charge . NOTE! If the engine does NOT stop by using the Riomote® control, contact Spartan Tool Customer Service .
Operating Instructions CLEANING A DRAIN LINE Attach a suitable nozzle onto the high-pressure hose . With the hose reel out of gear (Position D, page 21), pull the hose through the hose guide (6) to facilitate guiding the hose . The hose can be unwound short distances with the hydraulic hose reel out of gear .
Operating Instructions ATTENTION! Ensure that the spraying nozzle does not leave the drain while spraying . Water under high pressure may cause severe injury . STOP SPRAYING Depress the high pressure button (35) to shut the high pressure valve . •...
Operating Instructions CLEANING A WALL, TERRACE, OR FLOOR CAUTION! Before using a spray gun, set the jetter pressure below the maximum spray gun pressure (+/- half the maximum spray gun pressure) . Do this prior to starting the engine . Once the engine is running, jetter pressure can be increased by turning the HP regulator handwheel to the working pressure .
eController Errors EMERGENCY STOP The Emergency Stop icon illuminates on the eController when the Emergency Stop button is depressed . • Engine stops • High pressure valve closes • Pulsator valve closes (if equipped) • Hose reel switches off Operation can only be restarted after rotating the Emergency Stop button to release it . ENGINE TEMPERATURE The Engine Temperature icon illuminates when high engine temperature is detected (240°...
eController Errors HYDRAULIC OIL HIGH TEMPERATURE The Hydraulic Oil Temperature icon illuminates when high hydraulic oil temperature is detected . • Engine stops • High pressure valve closes • Pulsator valve closes (if equipped) • Hose reel switches off The operator can acknowledge the alarm display by depressing the Navigator dial in Manual Mode .
eController Errors BATTERY CHARGE The Battery Charge icon illuminates when low battery voltage is detected . • Engine stops • High pressure valve closes • Pulsator valve closes (if equipped) • Hose reel switches off The operator can override the alarm display by depressing the Navigator dial in Manual Mode and continue operation .
Maintenance CAUTION! Always stop the engine first and depressurize the system before servicing or repairing the machine . To depressurize the system, open the manual HP valve . If the spray gun is attached, you must also pull the trigger to release the pressure . DAILY MAINTENANCE Check Oil Levels •...
• If leakage is suspected, stop the machine, unscrew the hose coupling and clean or replace the pop-off valve on the unloader . Also, check the condition of the O-ring and gasket . (Contact Spartan Tool Customer Service for assistance .) b .
Maintenance HYDRAULIC SYSTEM IMPORTANT! Renew the hydraulic oil at least once a year! Replace the hydraulic fluid in the reel drive system . Check hydraulic oil level before each use . If level is not sufficient proceed as follows: Stop the machine . b .
Maintenance EXTENSIVE PERIODIC MAINTENANCE Have the high-pressure machine checked and maintained on a regular basis by a Spartan Tool technician . MAINTENANCE SCHEDULE Check oil levels Before each use Clean water filter Before each use Clean carriage Weekly Service engine...
Technical Specifications GENERAL SPECIFICATIONS Description Unit Dimensions See "Appendix B, Machine Dimensions" on page 40 Water tank capacity ~80 gal . per tank Fill medium Water (H20) maximum Temperature medium 132° F Total length of high-pressure hose ~360 ft . Diameter of high-pressure hose ½"...
Page 36
Technical Specifications PUMP Description Unit Type Speck P52 Maximum pressure See name plate on frame Maximum output See name plate on frame Weight 120 lbs . Maximum water temperature 60° C / 140° F Gear oil GX 80W90 Gear oil capacity 118 fl .
The high-pressure pump does not Air in the high-pressure pump . The failure will normally disappear . If not, produce the required pressure. contact Spartan Tool Customer Service . Carefully loosen the valves and de-scale Suction valves blocked . them, if necessary .
Page 38
Switch off the machine and clean the Hydraulic tank return filter dirty . return filter . Hydraulic system damaged . Contact Spartan Tool Customer Service . Recharge the battery . Use new battery . Contact points are dirty . No current .
APPENDIX A Engine Control Module The Engine Control Module (ECM) consists of two major functions . The function of the Engine Safety Protection Panel is to monitor engine parameters to alert the operator to any abnormal conditions requiring attention as well as any operating limits that may be exceeded requiring the machine to be immediately shut down . Once the engine is started, the ECM has primary control of the engine providing prealarms, alarms and safety shutdowns .