Advertisement

Quick Links

AD p.,!J.,ef
HPM-lOOA
HPM-lOOA
Power Meter
- - - - - --
User's Manual
. . .
.
.
. . . . .
.
. .
- -
-
..
�-
• Before using, please carefully read all contents and precautions of the manual.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPM-100A and is the answer not in the manual?

Questions and answers

Summary of Contents for adpower HPM-100A

  • Page 1 ♦ AD p.,!J.,ef HPM-lOOA HPM-lOOA Power Meter - - - - - -- User's Manual ..• �- • Before using, please carefully read all contents and precautions of the manual. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 2: Table Of Contents

    Contents - Foreword Accessory Before Using Warning, Upon Having a Problem Calibration Other Safty Precaution Chapter 1. Get Started Chapter 2. Part Names and Functions 2.1 Front View 2.2 Side View 2.3 LCD Screen View 2.4 Initial Setting Value 2.5 Display Font Chapter 3.
  • Page 3 Chapter 4. PC Communications (RS-232C) Set Up & Circuit Diagram 4.1 RS-232 Communications Setting 4.2 How To Change Transmission Speed 4.3 Circuit Diagram Chapter 5. GUI Program & Communications Protocol Specifications 5.1 GUI Program 5.2 Support Protocol & Common Communications Specifications 5.3 How To Change Communications Protocol 5.4 AD.01 Bus Protocol Specifications 5.5 AD.02 Bus Protocol Specifications...
  • Page 4 Foreword First, we would like to sincerely thank you for your selection of AD POWER products and wish your company every success in the future. Before using, please make sure to completely read and understand the product, PC communication, and GUI program manuals in order to maximize your work efficiency. Also, please contact us if you have any problem or instrument failure upon using our products.
  • Page 6 • The maximum voltage and current is AC 250V and 15A. Exceeding its maximum voltage and current may cause a serious damage or accident. • Measuring the load in the range from AC 10A to 15A (less than 30 seconds on each measuring,) please maintain at least 10 minute intervals in-between measurements.
  • Page 8: Side View

    9. Watt hour start/stop button : watt hour operation start/stop in the watt hours mode (LCD displays "ENERGY") ※ For the data logging equipment, it is used to start/stop logging. 10. CO2 setting value change button : Electricity charges and CO2 emission unit setting (in the watt-hour mode) ※...
  • Page 9: Lcd Screen View

    2-3 LCD Screen View 1) Data logging indicator: it blinks when data logging 2) Input power indicator: AC only 3) Pause indicator: pause displaying measurement / It blinks when the Key Lock is activated 4) Communication indicator: PC communication indicator 5) Measuring process indicator: when calculating watt hour, it displays "ENERGY"...
  • Page 10: Initial Setting Value

    2.4 Initial Setting Value 1) Communication protocol: AD.02 (for Wattman Viewer) 2) Communication speed: 9600bps 3) Electric power integration time: 1hour 4) Power rate: 188won (per kWh)/ varies with country. 5) Generation of carbon dioxide (Co2): 0.425kg (per kWh) 6) Initial value related to data logging - Data logging storage item: Voltage(V), Current(A), Active power(W), Electric power(Wh), Power factor(PF), Frequency(Hz), - Logging Interval: 1 second...
  • Page 12: General Specifications

    3-3 General specifications. • Standard Testing Temperature : 23 ℃, (± 4 ℃) • Effective Test Temp & Humidity: 10 ℃ ~ 50 ℃, (30 ~ 95%) • Storage Temperature : 10℃ ~ 60℃ • Material of Case : ABS Resin •...
  • Page 13: Setting Menu Tree

    3-5 Setting Menu Tree Measurement item display First of all, check if the supply voltage (source voltage) is the same as the rated voltage of the device to be measured. Basically, “Power consumption / Standby power measuring instruments” can measure up to 9mW ~ 3,750W.
  • Page 14: Current Range Setting

    3.7 Current Range Setting This instrument provides both auto and manual range measurement in current channel. The voltage channel has auto range measurement use only. Refer to the following current range configuration table. ※ The default range after power on is auto range. Channel Range RMS value...
  • Page 15 1) How to set manual current range. 2) Manual current range LCD display. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 16 3) Manual Range Overflow If an input current exceeds the maximum permissible RMS limit, alarm will sound and -OL- will be displayed. You must increase the manual range or change to auto range in this case.
  • Page 17: Overvoltage · Overcurrent Input Warning

    3-8 Overvoltage · overcurrent input warning If an input voltage or input current exceeds the maximum permissible limit, an alarm will sound or an alarm lamp will flicker. 1) If more than 500.0 V (AC voltage) is inputted, the -OL- flickering and the warning sound occur.
  • Page 18: Measurement Of Watt-Hour(Wh)

    3.12 Measurement of Watt-Hour(Wh) Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 19: Cautions At The Time Of Measuring Watt-Hour(Wh)

    ※ Cautions at the time of measuring Watt-Hour(Wh) Please be noted that Watt-Hour is activated as follows in order to avoid confusion in connection with PC communication data logging. If Wh function is used only, it is not applicable in this cautions. ①...
  • Page 20: Setting Electricity Charges And Co2 Emissions

    3-12 Setting electricity charges and CO2 emissions Wattman has a function to convert a calculated watt hours to electricity charges and CO2 emissions. Electricity charges and CO2 emissions per 1kWh can be adjusted when needed. 1) Measuring electricity cost The electricity charges is set based on the general households' electricity usage (approximately 300kWh) with a rate of 168 Won per 1 kWh.
  • Page 21: Green Coordinator

    3-13 Green Coordinator (Function to calculate a monthly and yearly estimates for electricity usage, electricity charges, and CO2 emissions) When you press the "HOLD" button and the "DISPLAY" button in the active power mode, Wattman will calculate and show a monthly and yearly estimate for watt hours usage, electricity charges, and CO2 emissions.
  • Page 22: Rs-232 Communications Setting

    •Aonower sustainability t:,,.oo • ""'""'- • Chapter4PCcommunication (RS232C) setting and circuit diagram 4-1 RS232C communication setting 1) Communication port: Connect a serial communication port or USB cable to the port that has been created. 2) Communication speed: 9600, 19200 3) Stop bit: 1 4) Parity, Flow control: No 4-2 How to change a communication speed 1.
  • Page 23: Circuit Diagram

    8. Exit the setting mode by pressing the "COST SET" button. 4-2 Circuit diagram 1) HPM-100A has the following circuit diagram for the isolation from PC. 2) Therefore, when you connect RS232C cable, connect it with the number 2 (RX), 3 (TX), 4...
  • Page 24 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 25 5.3 How to change the communication protocol 1. In order to change the communication protocol, press the "COST SET" button for a few seconds. 2. When the setting mode is open, press the "Wh RUN/STOP" button while "LOG" on the screen blinks. 3.
  • Page 27: Gui Program

    5.4.1 Supporting GUI program AD.01 Bus supports HPM-100 Viewer PC program, and it can be downloaded free of charge from www.adpower21.com. HPM-100 Viewer PC program supports only 9600 bps.
  • Page 28: Ad.02 Bus Protocol Specifications

    5.5 AD.02 Bus protocol specification Communication speed : 9600, 19200 bps. Command Rx over time between byte and next byte: 1 second. 5.5.1 Data transmission start command Commend Size of byte Function ‘S’ Command ‘#’ Closer 1) Transmitting data protocol: It continuously transmits data in an approximately 0.5s cycle. In a set of data, 'S' means the start of the data, and 'E' means the end of the data.
  • Page 30 5.5.2 Data transmission stop command Command Size of byte Function ‘E’ Command ‘#’ Closer 5.5.3 Watt hour control command Command Size of byte Function ‘W’ Command '0': starts the watt hour. ‘0’ or,’1’, or ‘2’ '1': stops the watt hour. '2': resets the accumulated values from the watt hour and the watt hour time into 0.
  • Page 31 5.5.4 Supporting GUI program AD.02 Bus supports Wattman Viewer program, and it can be downloaded free of charge from www.adpower21.com. Yet, Wattman Viewer program supports 9600 bps and 19200bps, which can be changed in the setting. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com...
  • Page 33 5.6.2 Data transmission stop command Command Size of byte Function ‘E’ Command ‘#’ Closer 5.6.3 Watt hour control command Command Size of byte Function ‘W’ Command '0': starts the watt hour. ‘0’ or,’1’, or ‘2’ '1': stops the watt hour. '2': resets the accumulated values from the watt hour and the watt hour time into 0.
  • Page 34: Chapter 6 Data Logging

    •Aonower sustainability t:,,.oo • ""'""'- • Chapter 6 Data Logging 6 Data logging 6.1 General specifications 1) storage medium: EEPROM 2Mbit 2) Storage capacity: About 9600 sets (When storing Voltage, Current, Active power, Power factor, Electric power and Frequency) 3) Dynamic logging: dynamically selective logging items(Voltage, Current, Active power, Power factor, Electric power and Frequency) and logging time interval to save up to 400days using internal memory.
  • Page 35: Time Setting Mode

    6-2 Time setting mode Time setting mode sets the time. If it reaches the set time, it is automatically finished. If you start it again after finishing, the number of logging increases (multi data logging). 1) If you want to set logging time, press the COST SET button for long. 2) If you enter the setting mode, the Log flickers.
  • Page 36 5) Set the time (date, hour, minute) you want to store. 6) HOLD(Up), Wh TIME SET(Down), DISPLAY(Move), Wh RUN/STOP(Apply) 7) By pressing the COST SET button, exit the setting mode. 8) If you press the Wh RUN/STOP button, data logging starts. If Wh is checked in the logging item at this time, the start and finish of logging is activated together with the start and finish of Wh.
  • Page 37: Run/Stop Mode

    6-3 RUN/STOP mode With ‘0’ in the time setting, the Run/Stop mode starts and stops by the user’s operation of the button. Whenever starting and stopping are repeated, the number of logging increases (multi data logging). 1) If you want to set logging time, press the COST SET button for long. 2) If you enter the setting mode, the Log flickers.
  • Page 38 4) The time you can store is indicated for about 2 seconds. 5) Set the time at ‘0’. 6) HOLD(Up), Wh TIME SET(Down), DISPLAY(Move), Wh RUN/STOP(Apply) 7) If you press the Wh RUN/STOP button, data logging starts. If Wh is checked in the logging item at this time, the start and finish of logging is activated together with the start and finish of Wh.
  • Page 40 •Aonower sustainability t:,,.oo • ""'""'- • Chapter 7Maintenance How to replace a fuse [Trouble] When power is connected, LCD is not turned on. Or while in use, LCD is suddenly turned off. In those cases, a fuse may have blown for a safety reason. [After sales service] http://www.testequipmentdepot.com/ The fuse of the electric power measuring device blows more because of loads �ample,...

Table of Contents