Download Print this page

Pro Products ProFeeder Installation & User Manual page 2

Advertisement

AUTOMATIC FERTILIZING
& PEST CONTROL SYSTEM
Turn OFF Water Main
1
SNAP RING
Turn OFF the water main, bleed
off pressure from mainline.
INJECTOR
Remove Siphon Cap
2
Remove the screw in the
center of the siphon cap.
Lift off so the injector is
exposed as shown. (Fig 1)
Fig 1
3
Remove Snap Ring
O RING
Press firmly on the top of the
INJECTOR BODY
INJECTOR with your thumbs to
relieve pressure on the SNAP RING.
SHOULDER (Inside Body)
Insert a screw driver into the LIFT
TAB and gently pull in and then up
to remove the SNAP RING.
ALIGNMENT
4
Remove Old Injector
TAB (Inside)
Grab the INJECTOR PORT and
gently pull up. The INJECTOR
should slide out easily.
WINTERIZATION &
SERVICE OF PROFEEDER
WINTERIZATION OF THE PROFEEDER
Do not inject air into a sprinkling system
that has a ProFeeder installed without first
SERVICE PLUG
installing a service plug or temporary bypass.
Injecting air into the sprinkling system will
spin the internal impeller and gear system of the
ProFeeder too fast which will cause damage
to the injector. The ProFeeder Service Plug is
designed to facilitate air injection for winterization or
temporary replacement of the
injector element for service.
2
REPLACING THE
INJECTOR UNIT
LIFT TAB
Clean & Reinsert O-Ring
5
Clean the O-RING. Apply a small amount
of plumbers grease before reinserting to
INJECTOR
PORT
ensure a good seal. Set the O-RING on the
SHOULDER inside the INJECTOR BODY
Insert the New Injector
6
Push the INJECTOR down until it stops.
Turn the INJECTOR clockwise until the
ALIGNMENT GROOVE & TAB meet allow-
ing it to nest inside the INJECTOR BODY.
ALIGNMENT
GROOVE
Firmly press down to ensure a snug fit.
Replace the Snap Ring
7
Make sure the LIFT TAB on the SNAP RING
is facing up and that it "snaps" into posi-
tion before restoring water pressure.
Turn ON Water Main
8
STAND AWAY FROM THE INJECTOR WHILE IT
IS PRESSURIZING
Check for leaks around
.
the SNAP RING and the INJECTOR PORT.
Reattach the siphon cap and continue
normal use.
LIFT TAB
SNAP RING
INSTALLING THE SERVICE PLUG
Turn off water main and bleed mainline
pressure before proceeding.
1
Remove Siphon Cap
2
Remove Snap Ring
3
Gently pull out injector
4
Insert Service Plug
O RING
5
Replace snap ring
6
Perform winterization services
INJECTOR BODY
7
Remove Snap Ring & Plug
SHOULDER (Inside Body)
8
Clean, Grease & Replace O-Ring
9
Clean build-up on Injector
10
Insert Injector
11
Replace Snap Ring
ALIGNMENT
TAB (Inside)
12
Replace Siphon Cap
AUTOMATIC FERTILIZING
& PEST CONTROL SYSTEM
RECOMMENDED USE
High flow range for spray and roter
zones. Dilution ratio of 10,000 -
15,000 : 1*
Moderate to High flow range. For
spray and rotor zones. Dilution
ratio of 4,000 - 5,000 : 1*
Low to Moderate flow range. For
spray zones and large drip zones.
Dilution ratio of 2,400 - 3,600 : 1*
*Gallons of water : 1 gallon fertilizer
PROFEEDER REPLACEMENT
PARTS LIST
Part #
Description
1
A1X-GTS
Internal Pump Mech
2
P1X-SVC Plug
Service Plug
3
R-O Ring
Internal O Ring (Black)
4
R-Snap Ring
Internal Snap Ring (Yellow)
5
A1X-TK-1
P1X Tubing Kit for 1 gallon bottle
6
A1X-UP2
Second generation siphon cap
INJECTOR NOZZLE GUIDE
OPERATING RANGE
up to 40 GPM
10 – 25 GPM
3 – 12 GPM
3

Advertisement

loading