5. MaiNTeNaNce
WarNiNG Only fully qualified personnel should attempt maintenance or repair.
5.1.
When not in use, ensure jaw remains in the open position to minimise corrosion on the ram piston.
5.2.
Keep the bead breaker clean and lubricate all moving parts on a regular basis.
WarNiNG DO NOT use brake fluid as this may cause serious damage to the jack and will invalidate the warranty! Only use a good
quality jack oil, such as seAleY HYdrAulic JAcK oil. note: ensure waste oil is disposed of in accordance with local authority
regulations.
5.3.
Before each use check for broken, cracked, bent, or loose parts, or any visible damage to welds, ram, pump, jaws, frame and all parts
including nuts, bolts, pins and other fasteners. if any suspect item is found, remove from service and take necessary action to remedy
the problem.
dO NOT use the bead breaker if believed to have been subjected to abnormal load or shock. inspect and take appropriate action.
8
iMpOrTaNT: NO reSpONSibiliTy iS accepTed FOr iNcOrrecT uSe OF The MachiNe.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the uK.
8
dO NOT return to sealey. Please telephone sealey on 01284 757500 to obtain the address and phone number of your local agent. if
breaker is under guarantee please contact your dealer.
de-commissioning the bead breaker
should the bead breaker become completely unserviceable and require disposal, draw off the oil into an approved container and
dispose of the jack and the oil according to local regulations
6. TrOubleShOOTiNG
Symptom
• Claw or shovel erratic.
• System is pressurised but the bead breaker
is not responding.
• Claw will not close or shovel will not fully
extend or withdraw.
• Bead breaker will not maintain pressure.
• Oil leaking.
• Bead breaker will not open and/or shovel
stuck or slower than normal.
environmental protection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment.
Weee regulations
dispose of this product at the end of its working life in compliance with the eu directive on Waste electrical and electronic
equipment (Weee). When the product is no longer required, it must be disposed of in an environmentally protective way.
contact your local solid waste authority for recycling information.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMpOrTaNT: no liability is accepted for incorrect use of this product.
WarraNTy: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack sealey limited
.
possible causes
• External leakage.
• Binding sticking or components.
• Loose or faulty hydraulic connections/couplers.
• Oil level in pump is low.
• Pump not operating.
• Oil in pump is low.
• Sticking rams or binding components.
• Pump malfunctioning.
• Seals leaking.
• Worn seals.
• Faulty coupler.
• Pump reservoir over filled.
• Internal damage.
• Linkage binding.
sole uK distributor, sealey Group.
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk.
iP32 7Ar
Original Language Version
corrective action
• Contact Sealey dealer for service.
• Clean and lubricate all moving parts.
• Depressurise Tighten/replace
connections/couplers.
• Depressurise and fill the pump.
• Consult pump instruction manual.
• Depressurise and fill the pump.
• Contact Sealey dealer for service.
• Consult pump instruction manual.
• Contact Sealey dealer for service.
• Contact Sealey dealer for service.
• Depressurise Tighten/replace
connections/couplers.
• Depressurise and drain fluid to correct
level.
• Contact Sealey dealer for service.
• Clean and lubricate all moving parts.