Aqua Guard MasterPro Series Owner's Manual

Pool cartridge filter

Advertisement

Quick Links

Notice to Installer
This manual contains important information on the operation, and safe use of this
equipment. This manual is intended for the end user of this product
aquaguardpoolsystems.com
MasterPro
Pool Cartridge Filter
Owner's Manual
Installation, Operation and Service
Models: MP425, MP525
WARNING
This equipment must be installed and serviced by a qualified
technician in accordance with all applicable codes and
ordinances. Improper installation can create hazards which could
result in property damage, serious injury or death. Improper
installation will void the warranty.
The NOTICE label indicates special instructions that are
important but not related to hazards.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MasterPro Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Aqua Guard MasterPro Series

  • Page 1 MasterPro Pool Cartridge Filter Owner’s Manual Installation, Operation and Service Models: MP425, MP525 WARNING This equipment must be installed and serviced by a qualified technician in accordance with all applicable codes and ordinances. Improper installation can create hazards which could result in property damage, serious injury or death.
  • Page 2: Table Of Contents

    Table of Contents Safety Information ................2 Filter Re-Assembly ................7 Product Specifications ..............3 Trouble Shooting ................8 Installation ................... 4 System Inspection ................9 Initial Startup ..................5 Winterizing ..................9 Maintaining Your Filter ..............5 MasterPro Parts Listing ..............10 Cartridge Cleaning ................
  • Page 3: Product Specifications

    Cartridge Filtration Description Unpacking Inspect unit before it is used. Occasionally, products are This pool filter is designed to remove debris and particulates damaged during shipment. If filter or components are from permanently installed swimming pools and spas. It damaged, return unit to place of purchase for replacement. is equipped with a removable cartridge that can be easily Failure to do so could result in serious injury or death.
  • Page 4: Installation

    TYPICAL HEAD LOSS Flow (GPM) Installation Equipment Inspection NOTE: This filter should only be installed by qualified 1. The filter system should be installed on a level concrete personnel. slab or other rigid base. Select a well drained and vented area, one that does not flood when it rains.
  • Page 5: Initial Startup

    FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 Time to Manual air relief shown open. Clamp Nut Clean Manifold Drain Plug 7-10 PSI Filter Cartridge Pressure Reaches w/ O-Ring Red Arrow Clean Pressure Place Green To Open To Close Arrow Hear Lower Body 0 PSI...
  • Page 6: Cartridge Cleaning

    Cartridge Cleaning NOTICE: The pressure gauge is the primary indicator of filter performance. Maintain the pressure gauge in good working order. If the gauge is damaged, replace it immediately. When to clean the filter The filter cartridge should normally be removed and cleaned when the pressure gauge reads 8 - 10 PSI above the start-up pressure noted below: Installation date:...
  • Page 7: Filter Re-Assembly

    FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 Tighten clamp bolt and nut using a torque wrench to Clamp Nut 150 inch-lbs. To Open Align Clamp Nut Labels Drain To Open Plug Lower Rounded end of nut Filter Body Clamp Bolt Filter Re-Assembly WARNING: This product 4.
  • Page 8: Trouble Shooting

    Trouble Shooting Short Cycle Time Plugged Cartridge Cycle time will vary between installations and different areas Over time, the filter media will become clogged and will of the country. Check the following to remedy this problem: not perform properly. If the cartridge cannot be cleaned, replace it.
  • Page 9: System Inspection

    System Inspection The pool circulation system should be frequently inspected 7. Replace the pump basket and trap cover according to the for debris and signs of leaks. pump owner’s manual. WARNING: Any time the system is opened, air must be 8.
  • Page 10: Masterpro Parts Listing

    MasterPro Parts Listing Models: MP425, MP525 No. Part Number Description Req’d Qty AGX60033-01 Pressure Gauge AGX60033-02 Manual Air Relief Assembly AGX60034-03 Upper Filter Body for MP425 AGX60033-03 Upper Filter Body for MP525 AGX60033-04 Clamp System Includes Clamp, Clamp Nut and Bolt, Hang Tag, Metal Reinforced Seal, and Labels) AGX60033-05...
  • Page 11: Warranty

    Limited Warranty For one (1) year from the date of purchase, will repair or replace, at its option, for the original owner any parts of its filters (“Product”) which are found upon examination to be defective in materials or workmanship. This Limited Warranty covers parts only for a period of one (1) year.
  • Page 12 Thank you for choosing AquaGuard! aquaguardpoolsystems.com...

This manual is also suitable for:

Mp425Mp525

Table of Contents