THIS UNIT CONTAINS A
RECHARGEABLE VALVE-REGULATED
LEAD ACID BATTERY. PLEASE
RECYCLE OR DISPOSE OF
PROPERLY.
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM
BEFORE CONTACTING TECHNICAL SUPPORT PLEASE REFER TO THE TROUBLESHOOTING GUIDE INCLUDED IN
i
THIS MANUAL.
1. DO NOT USE OUTDOORS.
2. All unused wires must be insulated to prevent shorting.
3. Do not mount near gas or electric heaters.
4. Do not let power supply cords touch hot surfaces.
5. Do not use this equipment for other than its intended use.
6. The LMIU should be mounted securely and in locations and at heights where it will not be readily subjected to tampering by
unauthorized personnel.
7. The use of accessory equipment and replacement parts not recommended by manufacturer may cause an unsafe condition and
void the warranty.
8. The AC voltage rating of this equipment is specified on the product label. Do not connect the LMIU equipment to any other voltage.
9. Replacement fuse is supplied.
10. The LMIU uses sealed valve regulated lead acid batteries. Batteries can be punctured if not handled properly, therefore use caution
when servicing batteries. In the event battery acid comes in contact with eyes or skin, flush with fresh water and consult a physician
immediately.
11. Install in accordance with the National Electrical Code and local regulations.
12. The LMIU contains potentially hazardous voltages. Installation, maintenance and service work should be performed by qualified
and trained personnel.
13.
Electricians and end-users need to ensure product system compatibility before final installation.
14. Units to be installed only as per configuration described in this instruction manual.
MODEL NUMBER
LMIU-125
LMIU-250
120/277 VAC, 60Hz
LMIU-400
IMPORTANT: Do not exceed the total rating of the Mini Inverter. Unit is rated at maximum Watt and maximum VA, where Max.W
= Max.VA. Total load (W) must be derated when load power factor (PF) is less than 0.9 (for maximum performance)
All LightAlarms inverter products receive 100% quality inspection before shipment to ensure proper and satisfactory operation.
When operated under normal conditions, LightAlarms inverter products will provide years of dependable service. This unit is backed by a
3-7 year warranty. The unit is covered by a complete 3-year warranty against defects in material or workmanship, and a 7-year pro-rata
battery warranty.
LightAlarms
Tel: (888) 552-6467
LMIU 125/250/400W Mini Inverter
INTERRUPTIBLE EMERGENCY LIGHTING
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS
AC SPECS
1.50 / 0.70 Amps
2.75 / 1.20 Amps
4.60 / 2.00 Amps
WARRANTY
Fax: (800) 316-4515
UNIT INVERTER INSTRUCTION MANUAL
EMERGENCY POWER AVAILABLE FOR LOAD
90 MIN
2H
125W
85W
250W
170W
400W
300W
www.lightalarms.com
LMIU 125/250/400W Mini Inverter
APPROX.
WEIGHT
3H
4H
65W
50W
50LBS.
125W
95W
100LBS.
200W
150W
150LBS.
.
06/18 750.1783 Rev. G
1/12
Need help?
Do you have a question about the LMIU 125W and is the answer not in the manual?
Questions and answers