Download Print this page

ProFlo PF91025 Owner's Manual page 4

Submersible utility pumps

Advertisement

WARNING
A
LWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO INSTALL
.
PERFORM MAINTENANCE ON THE PUMP
FAILURE TO DO SO MAY RESULT IN FATAL ELECTRICAL SHOCK
INSTALLATION/OPERATION
1.
Place the pump on a hard surface in the water. Do not set the pump directly in mud or sand. This
may cause the intake screen to clog or damage to your pump.
2.
The water level must be at least 1" deep for the pump to operate.
3.
Plug the power cord into a grounded 120-volt AC outlet. The pump will start to operate as soon
as the cord is plugged in.
4.
The pump should be turned off once the water reaches these levels.
5.
Do not let the pump run dry. The pump depends on water for cooling and lubrication. Operating
the pump without water may cause the motor to overheat or cause damage to parts of the pump.
It may also shorten the life of your pump.
Anything that will pass through the intake screen holes will pass through the pump without causing
damage. The intake screen on the pump removes easily for cleaning. The units can also be back-
flushed using the garden hose adapter (select models only).
NOTE: This pump has a built in anti-airlock device. Leakage is normal from this device.
TROUBLESHOOTING
WARNING
A
LWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO INSTALL
.
PERFORM MAINTENANCE ON THE PUMP
FAILURE TO DO SO MAY RESULT IN FATAL ELECTRICAL SHOCK
If the pump does not start or run.
1.
Make sure pump is plugged in.
2.
Check for blown fuses or tripped circuit breakers or tripped GFCI outlets.
If the pump runs and moves little or no water.
1.
Check to insure discharge pipe is not plugged.
2.
Unit may be air locked. This pump has an anti-airlock device built in. Clean out airlock.
3.
Check intake screen for obstructions, clean if necessary.
4
NOTICE
,
Height and/or piping restriction will reduce the pump output performance. See the
SERVICE OR
.
performance chart below to insure you have the proper pump for your application. Whenever possible
use the same or larger size pipe than the pump discharge for optimum performance. Reducing the
pipe size will not harm your pump; it will just reduce the output.
PF91250, PF91251, PF91255, PF91257
PF91330, PF91331, PF91335
Model
HP
Amps
Solids
Handling
,
SERVICE OR
Warranty
.
(Years)
Discharge
Size
Pump Down
Level
Power supply requirements
Motor
Liquid Temperature Range
Circuit Requirements
***For continuous duty, the pump must be submerged to prevent overheating
PERFORMANCE CHART
Discharge Height Above Pumping Level
Model
0'
5'
Gallons per Minute
PF91025
26
21
30
22
40
34
PF91501
70
66
SPECIFICATIONS
PF91250
PF91251
PF91330
PF91025
PF91255
PF91257
PF91335
1/4
1/4
1/4
3.61
3.82
3.82
1/8"
1/8"
1/8"
1
1
3
1 ¼"
1 ¼"
1 ¼"
1/8"
1/8"
1/8"
120V, 60 Hz
Continuous Duty***, Capacitor Start,
Thermally Protected
32° F - 120° F (0° C - 49° C)
15 amp
5
10'
15'
20'
25'
14
10
7
1
20
16
9
2
28
22
12
2
58
48
25
10
PF92331
PF91501
1/3
1/3
1/2
4.1
4.1
7.6
1/8"
1/8"
1/2"
1
3
3
1 ¼"
1 ¼"
1 ½"
1/2"
1/2"
1"