1. Daily check list:
A. Oil level (top off as needed)
B. Engine coolant level (top off as needed)
C. Diesel fuel level in fuel tank
D. Tap dirt out of air intake housing and check for excessive dirt
E. Clean debris off radiator
Consult the supplied HATZ Engine Service Manual, the MURPHY Electronic Control Panel
Manual and the Service Manual of the PTO Manufacturer, such as WPT Power or NACD.
2. Periodic Maintenance (See Page 25 for More Details)
A. Change oil and oil filter
B. Clean/replace fuel filters as needed
C. Clean and inspect air filter and replace as needed
D. Grease both (inside and outside) fan bearings every 2 - 4 months
(Do NOT over-grease)
E. Adjust and grease PTO per supplied PTO Service Manual
F. Inspect adjustment of coupler hubs and realign by re-adjusting the engine
isolators (motor mounts) as needed
G. Check alternator V-belt and adjust as needed
Contact Air Burners, Inc., should you require assistance with any of these
necessary maintenance tasks. Send Email to support@airburners.com,
The engine does not require DEF.