Download Print this page

Offshore 3350-GTPO Installation And Operating Instructions

Grey tank pump out controller

Advertisement

Quick Links

GREY TANK PUMP OUT CONTROLLER
Part Number: 3350-GTPO Grey Tank Pump Out Controller
INSTALLATION AND OPERATING INSTRUCTIONS
The 3350-GTPO Grey Tank Pump Out Controller is designed to display the contents of the Grey Tank and control
the pumping out of that tank.
The 3350-GTPO is housed in a standard 2" / 52mm diameter panel gauge instrument that contains a blue LED
digital display, front panel "START" and "STOP" buttons and a 10 Amp changeover relay to control the pumping
out pump.
It has a standard NMEA2000® micro sized male plug to link to the NMEA2000® network and 3 x ¼" male spade
terminals to link to the pump wiring.
Display
Transferring
LED Indicator
NC-Terminal
C-Terminal
NO-Terminal
SAFETY WARNING
This instrument should only be installed by a person competent and experienced in working on electrical systems
on boats.
BEFORE BEGINNING WORK THE BATTERY SHOULD BE DISCONNECTED TO AVOID THE RISK OF A SHORT CIRCUIT,
A FIRE OR AN EXPLOSION.
Before drilling any holes to mount the unit or to run the cabling always make sure it is safe to do so.
GREY TANK
Tank Pumping Out
START
STOP
Unit Address Switch
1
INSTALLATION AND LOCATION
The 3350-GTPO Grey Tank Pump Out Controller displays the tank level as a % level and should be situated within
sight of the helm position.
If there are multiple helm positions then multiple instruments can be installed. In this event the pump control
wiring can be connected in parallel so that either instrument can control the pump out of the tank.
The instrument is designed to be panel mounted in a 2" or 52mm clearance hole and requires clearance of at
least 100mm behind the hole to allow for cable connections to be run without undue stress.
It is fixed to the panel by using a reversible rear mounting ring nut which can accommodate panels of up to 25mm
thick. The front of the instrument is sealed to IP67 and when correctly mounted in a panel using the supplied
gasket will provide an IP67 seal to the panel.
A mounting hole providing clearance for a 2" / 52mm diameter should be cut at the desired location. The
instrument should be inserted from the front with it's gasket. The mounting ring nut is attached at the rear and
tightened sufficiently to hold the instrument securely.
THE UNIT ADDRESS SWITCH ON THE BACK OF THE INSTRUMENT MUST BE SET TO EXACTLY MATCH THE UNIT
LED Indicator
WIRING AND NETWORK
The male NMEA2000® micro plug should be attached to a Tee connector on the NMEA2000® network either
directly or by using a NMEA2000® micro drop cable.
The wiring to the transfer pump should be as follows:
Through-hull fitting
The power control cables on the back of the 3350 HTPO should be connected to the "C" and "NO" terminals.
ADDRESS SWITCH ON THE GREY TANK LEVEL SENDER. IF THIS IS NOT DONE CORRECTLY
THE UNIT CANNOT AUTOMATICALLY STOP A TRANSFER.
Holding Tank Pump Out Controller
Transfer
Pump
Seacock
or valve
3802 T - Adaptor
NMEA2000® Network Backbone
Waste Tank

Advertisement

loading

Summary of Contents for Offshore 3350-GTPO

  • Page 1 Part Number: 3350-GTPO Grey Tank Pump Out Controller INSTALLATION AND OPERATING INSTRUCTIONS The 3350-GTPO Grey Tank Pump Out Controller displays the tank level as a % level and should be situated within sight of the helm position. The 3350-GTPO Grey Tank Pump Out Controller is designed to display the contents of the Grey Tank and control the pumping out of that tank.
  • Page 2 Offshore Dynamics products are designed to be accurate and reliable. However, The 3350-GTPO Controller can be cleaned with mild soap and water. Do NOT use solvents or abrasive or pressure they should be used only as aids to vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring washers as these could damage the front of the instrument.