I/O DEVICE EDIT screen
This screen is displayed when you select the desired I/O device in the I/O DEVICE screen
(AMP page). You can remotely control the amplifier or the speakers.
 For NEXO NXAMPmk2
2
5
1
8
:
9
A
C
B
1
STATUS indicator
Indicates the status of the device.
Status
OVERALL
Overall status of the device
ALERT
Alert
AMP
Operating status of each amplifier channel
PS
Operating status of power supply unit
FAN
Operating status of each FAN unit
*
ALERT indicator display is green and red only. When an alert occurs, the indicator turns red and the alert
contents are displayed at the bottom of the screen.
2
SCENE
Displays the recalled scene number and title.
3
4
6
7
Indicator display
Green:
Normal operation
Yellow:
Fault detection
Orange: Temporary malfunction
Red:
Malfunction that cannot
be resolved
3
CABINET
Displays the name of NEXO Setup selected in the NXAMP.
4
VERSION
Displays the firmware version of the device.
5
INPUT METER
Displays both the input analog input levels and digital input levels.
6
STANDBY button
Switches the standby mode on or off.
7
OVERMUTE button
Switches the over mute (mute all channels) on or off.
8
Output level meter
Displays the output level of the channel.
9
VOLUME knob
Sets the channel volume.
0
LIMIT indicator
Lights while the limiter for amplifier or power supply protection is applied.
A
PROTECT indicator
Lights while the limiter for speaker protection is applied.
B
MUTE button
Switches the channel mute on or off.
C
Channel name
Displays the channel name (the speaker preset name for the NXAMP).
8