Table 5.3. Environmental specification
Item
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Vibration resistance
Impact resistance
Floating dust particles
Corrosive gases
*
The values in the above are constrained with the boards or the components such as drives installed inside the
product, so the figures do not necessarily represent the tolerances for every operating condition.
Dimensions of installable board (Max.)
340.5 (L)
PICMG / Full size ISA
312.98 (L)
Full size PCI
CAUTION
The internal power supply and cooling fan, fan filter are consumables, requiring replacement after
use for a certain period of time.
Although the standards are given below, their lives may be shortened depending on the operating
environment. The life span is likely especially to become short extremely in the place which takes
influence of trash, metallic powder, the place which is much dust or oil, corrosive gas.
- Power supply
- Cooling Fan
- Fan filter
22
0 - 50 ° C
10 - 80%RH (No condensation)
0 - 60 ° C
10 - 90%RH (No condensation)
10 - 57Hz/semi-amplitude 0.075mm, 57 - 150Hz/1.0G
10G half-sine shock for 11ms
Not to be excessive
None
210.0 (L)
Middle size PCI
:
About 5 years (25°C, 60%, 75% load, official environment)
:
About 5 years (25°C, 60%, official environment)
:
About 1 year (25°C, 60%, official environment)
Specification
[mm]