RHINO PSP Series Installation Instructions

Dc - dc converters

Advertisement

R
PSP S
hino
Installation Instructions PSP Series DC - DC Converters

Input Specifications

Input Voltage
Part Number
Range
PSP**-DC12-*
9.5 to18.0 VDC
PSP**-DC24-*
18 to 75 VDC

Output Specifications

Output
Part Number
Voltage
PSP24-DC12-1
24 VDC
PSP05-DC24-5
5 VDC
PSP12-DC24-2
12 VDC
PSP24-DC24-1
24 VDC
*Note: Input variation V in min to V in max and load variation 0 to 100%

General Specifications

Temperature
Humidity (Non-condensing)
Temperature Coefficient
Switching Frequency
Isolation Voltage (1 min.) – Input/Output
Reliability, Calculated MTBF @ 25°C
Safety Standards
Electromagnetic Compatibility (EMC)
Safety Class
Parallel Operation
Connections
Wiring
Enclosure Rating
Enclosure Material
Mounting
Agency Approvals
Note: All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.

Dimensions and Wiring

OUTPUT
1 2
DC-ON LED
Output voltage
adjust
1
INPUT
RHINO Industrial Power Supplies PSP Series , DC - DC models Installation Instructions
DC - DC C
eRieS
Input Current
@ V in = 12 VDC
I out = 0%
I out = 100%
80mA max
2.5A max
@ V in = 24 VDC @ V
in = 48 VDC @ V in = 24 VDC @ V in = 48 VDC
I out = 0%/100% I
out = 0%/100% I out = 0%/100% I out = 0%/100%
80mA max/1.3A max
60mA/0.7A max
Output
Output Voltage
Current
Adj. Range
(max.)
24.0 - 28.0 VDC
1 A
5.0 - 5.25 VDC
5 A
12.0 - 15.0 VDC
2 A
24.0 - 28.0 VDC
1 A
General Specifications
2
3
Weight: 140g (4.9 oz)
Input Specifications
Power Consumption
@ V in = 12 VDC
I out = 0%
0.96 watt typical
1.92W/31.2W typical
Output Specifications
Output
Ripple/
Voltage
Noise
Regulation*
<50mV
±0.5 % max
peak to peak
Operating: -10°C to 70°C max (14°F to 158°F max);
Storage (non-operating): -25°C to 85°C max, (-13°F to 185°F max); Derating: 1.5%/C above 50°C (122°F)
95 % relative humidity max.
0.02 %/C
55 – 180 kHz depending on load (frequency modulation)
1500 VDC
>2.5 Mio h (according to IEC-1709)
IEC 60950-1, EN 60950-1 (output SELV), UL/cUL 60950-1, EN 60204
Emissions: EN 61000-6-3; Immunity: EN 61000-6-2
Degree of protection class 1
No parallel operation
Screw type plug-in connector (standard). Recommended tightening torque 0.5 to 0.7 Nm (4.5 to 6.2 lb.in)
2
2
0.21mm
- 3.16mm
(AWG 24 to AWG 12)
IP 20 (IEC 60529)
Plastic FR2010-110C (UL 94V-0 rated)
DIN rails per EN 50022-35x15/7.5 (snap-on with self-locking spring) bracket for wall/chassis mount included
UL/cUL 508 Listed, File E197592, CE
100.0
(3.94)
onveRteRS
Startup
Undervoltage
Voltage
Shut-down
I out = 100%
30 watt typical
8.4 VDC
2.88W/33.6W typical
17.2 VDC
Overvoltage
Short Circuit
Protection,
Protection
Trigger Point
<42 V
<6.5 V
Current limited at
110% typical
<24 V
<42 V
27
(1.06)
Tolerances: ±0.5mm (±0.02)
Rev: 06/18
1-800-633-0405
Efficiency
(Typical)
7.6 VDC
86%
15.7 VDC
86%
MTBF (IEC 1709 @
25°C)
2.5 million hours
Input Output
1 Ground 1 +Vout
2 -Vin
2 -Vout
3 +Vin

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RHINO PSP Series

  • Page 1 Output voltage adjust Input Output 1 Ground 1 +Vout 2 -Vin 2 -Vout 3 +Vin (1.06) INPUT Weight: 140g (4.9 oz) Tolerances: ±0.5mm (±0.02) RHINO Industrial Power Supplies PSP Series , DC - DC models Installation Instructions Rev: 06/18 1-800-633-0405...
  • Page 2 5. Verify the DIN rail clip is securely fastened on DIN rail. 6. Connect wires as indicated on converter. The unit can be mounted on a chassis or wall using the includ- ed mounting bracket. RHINO Industrial Power Supplies PSP Series , DC - DC models Installation Instructions Rev: 06/18 1-800-633-0405...

This manual is also suitable for:

Psp24-dc12-1Psp12-dc24-2Psp24-dc24-1Psp05-dc24-5

Table of Contents