  • Page 1 Quick Installation Guide Proximity / PIN Access Controller...
  • Page 2 ※ LX505/LX505SR QUICK INSTALLATION GUIDE 1. WHAT‟S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor or IDTECK. LX505/LX505R Wall Mount Manual CD Quick installation Guide 2PIN connector (1ea) Diode (2ea) 2.2K resister (4ea)
  • Page 3: Front Panel

    There are 12 menu buttons (F1 to F12). Press a menu button to enter the ○ Menu Button corresponding menu. (F10 to F12 menu buttons are unavailable for LX505/LX505SR) ○ It is the numerical button to input number or to define direction.
  • Page 4 Code Description ○ Connect the RJ45 jack and use it in case of TCP/IP communication. RJ45 Connector If someone disassembles the installed LX505/LX505SR on wall by force, the tamper ○ Tamper Switch switch is activated then buzzer makes sound. ○...
  • Page 5 ※ LX505/LX505SR QUICK INSTALLATION GUIDE 2.3 Connection and Color Code Table I/O PORT NAME SIGNAL NAME WIRE COLOR CON-1(2PIN CONNECTOR) Main Power (+12V) Main Power (+12V) Power Ground Power Ground Black CON-2 (3PIN CONNECTOR : SERIAL PRINTER) RS232-RX RS232-RX Pink wire with white stripe...
  • Page 6: System Configuration

    ※ LX505/LX505SR QUICK INSTALLATION GUIDE 3. SYSTEM CONFIGURATION RS232 RS232/RS485 Converter RS485 Host PC RS485 DC12V Power Supply DC12V Power Supply RF Reader Exit Button Door Lock RF Reader Exit Button Door Lock (Figure: System Configuration)
  • Page 7: Wall Mount Installation

    After the wiring is done, put the LX505/LX505SR on the Wall Mount and screw it. (Figure: Wall Mount) Caution Do not install LX505/LX505SR on a metal wall. Otherwise, the radio frequency from the metal frame will make reading range of the card shorter.
  • Page 8: Power Connection

    (Applicable to Aux Input #1(Green wire), Aux Input #2(Green with white stripe wire)) - Connect one wire of Auxiliary Input Device to one of Aux Input #1 or Aux Input #2 of LX505/LX505SR. - Connect the other wire from Auxiliary Input Device to GND of LX505/LX505SR.
  • Page 9: Output Connection

    ※ LX505/LX505SR QUICK INSTALLATION GUIDE Caution You have to connect a 2.2K resistor between the input wire and the GND for the Cut Off Check function. Select whether or not to check the cut off status of each device in „Cut Off Check‟ of [F5 SETUP MENU].
  • Page 10 Secure. But separate power source must be applied and use external Relay in both Power Fail Secure and Power Fail Safe door lock. (Figure: 24V Door Lock and Automatic Door Connection) Caution If you don‟t use separate power source and external Relay for the 24V door lock, relay of LX505/LX505SR may have damages and some malfunctions will appear.
  • Page 11: External Reader Connection

    - Connect (-) wire of the Proximity Reader to GND(-) of power supply. - Connect Data-0 wire of the Proximity Reader to the Pink wire of LX505/LX505SR. - Connect Data-1 wire of the Proximity Reader to the Sky Blue wire of LX505/LX505SR.  Compatible Readers (External Reader)
  • Page 12: Communication Connection

    (Figure: RS232 Communication Connection) - Connect RS232-TX (Black with White stripe wire) of LX505/LX505SR to the pin #2 (RXD) of 9-pin connector. - Connect RS232-RX (Red with White stripe wire) of LX505/LX505SR to the pin #3 (TX) of 9-pin connector.
  • Page 13 ※ LX505/LX505SR QUICK INSTALLATION GUIDE 5.5.2 RS485 Communication Connection for Standalone Unit An RS485/RS232 converter is needed to for RS485 communication between the LX505/LX505SR and a host PC. Please follow the steps below. RS232 RS485/RS232 Convertor Host PC RS485 Termination Resistor Max.
  • Page 14 (Figure: RS485 Communication Connection for Multiple Units) First, connect RS485 port of all LX505/LX505SRs in parallel. (Maximum of 32 LX505/LX505SR) - Connect RS485-RTX (+) (Yellow wire) of one LX505/LX505SR to RS485-RTX (+) (Yellow wire) of another LX505/LX505SR. - Connect RS485-RTX (-) (Gray wire) of one LX505/LX505SR to RS485-RTX (-) (Gray wire) of another LX505/LX505SR.
  • Page 15 5.5.4 TCP/IP Communication Connection (Only for LX505T/LX505SRT) Follow the instruction below for TCP/IP communication. (Figure: TCP/IP Communication between Multiple LX505 units and a host PC) - Connect the RJ45 plug of LAN cable from the HUB to the RJ45 jack of the LX505T/LX505SRT.
  • Page 16 ※ LX505/LX505SR QUICK INSTALLATION GUIDE 2) To search TCP/IP Module connected with LX505/LX505SR controller, click ‘Search’ button. 3) All TCP/IP Modules connected on network are displayed. In the ‘Board List’, MAC address of TCP /IP Module is displayed. 4) Check MAC address of TCP/IP Module (described on TCP/IP module) and then select it. Setting...
  • Page 17 ※ LX505/LX505SR QUICK INSTALLATION GUIDE 5) Select „Network‟ tab. Input network information of selected TCP/IP module to „Local IP‟, „Subnet‟, „Gateway‟. Network information can be assigned from network manager. Input „5000‟ for „Port‟, „0.0.0.0‟ for „Server IP‟(default), „0‟ for „Server IP Port‟. Select „Server Mode‟ for „Network Mode‟.
  • Page 18 ※ LX505/LX505SR QUICK INSTALLATION GUIDE Column Name Setting Value Inactivity Time 30000 Time Size Char 8) If all setting process is completed, click „Setting‟ to apply network information to TCP/IP module. After setting is completed, „Complete Setting‟ message is displayed. Click „OK‟ and finish setting process.
  • Page 19 LX505/LX505SR QUICK INSTALLATION GUIDE 5.5.5 Serial Printer Connection (Optional) A 9-pin connector (serial communication connector, female) is needed to connect the LX505/LX505SR with a serial printer via RS232 communication. Please follow the steps below. (Figure: RS232 Communication between LX505/LX505SR and a Serial Printer) - Connect RS232-TX (sky blue with white stripe) wire to the pin #2 (RXD) of the 9-pin connector.
  • Page 20: Initial Setting

    6.1 Initialization Initialize the system using the Initialization switch on the back of the LX505/LX505SR. 1. Check whether the power terminal on the back of LX505/LX505SR is connected or not. If it has been connected, disconnect the power cable. 2. While holding the Initialization switch, connect the power cable.
  • Page 21: Language Setting

    LX505/LX505SR QUICK INSTALLATION GUIDE 6.2 How to enter the MASTER MODE You must enter the MASTER MODE first to initialize LX505/LX505SR or change the basic setting. 1. Press „0‟ key eight times (00000000) and press <ENT> key. ※ Initial Master ID for LX505SR is that pressing <0> key ten times.
  • Page 22: Date/Time Setting

    ※ LX505/LX505SR QUICK INSTALLATION GUIDE 6.4 Date / Time Setting 1. Press the [F1] SETUP MENU button. 2. Using <4> and <6> keys, move to „2. SET DATE/TIME‟ and then press <ENT> key. 2. SET DATE/TIME 3. Enter the values of year, month, day, hour, minute, second, and day of the week in sequence.
  • Page 23: Communication Address Setting

    6.6 BAUD RATE SETTING LX505/LX505SR supports 9600, 19200, 38400, and 57600 bps, and the default baud rate is 57600 bps 1. Press the [F1] SETUP MENU button. 2. Using <4> and <6> keys, move to „8. BAUD RATE‟ and then press <ENT> key.
  • Page 24 1 – CARD, 2 - PIN ※ If you select card, you can register the ID through card. For PIN registration, select PIN and use the keypad to register the ID. 4. Present the card onto the LX505/LX505SR. 1. REGISTRATION SCANNING…...
  • Page 25 ※ LX505/LX505SR QUICK INSTALLATION GUIDE ※ ID Registration Item (PW /TA/TB/C/RD/MA/MB/LV) Item Description 4-digit password Time schedule code for READER#1 (Internal reader) Time schedule code for READER#2 (external reader) Permission code for the user ID Description Normal card 2-Man Operation (administrator)
  • Page 26 ※ LX505/LX505SR QUICK INSTALLATION GUIDE 6.8 ID DELETION The registered ID can be deleted by presenting corresponding card or keypad input. 1. Press the [F7] SETUP MENU button. 2. Using <4> and <6> keys, move to „2. ID DELETE‟ item and then press <ENT> key.

This manual is also suitable for: