GENERAL SAFETY INFORMATION
These instructions are for your protection and convenience. Please read them carefully since failure to
follow these precautions could result in injury or even death.
Always use the EPF-30P in accordance with the required operation standards listed below.
Never put the EPF-30P into standing water or allow water inside the motor.
Never store the EPF-30P outdoors.
Never allow the air intake screens to become plugged.
Never put any object in the intake screen unless the unit is disconnected from the air supply line
and the fan blade has stopped turning.
Do not allow the unit to be used as a toy. Close attention is necessary when used by or near
children.
Keep hair, loose clothing, fingers, and all parts of the body away from the intake screen.
If the fan is not working properly because it has been dropped, damaged, left outdoors, or submerged in
water, contact us at 903-498-3363.
INSTRUCTIONS FOR OPERATION AND CARE
FOR ALL APPLICATIONS
1. 100 psi maximum.
2. Clean, dry, lubricated air supply required, coupler plate.
FOR HAZARDOUS LOCATIONS
1. Ground unit at lug on coupler plate
2. Air supply lines shall be made of electrically conductive material in accordance with the
recommended practice on static electricity, NFPA 77, and/or any other applicable local code.
Your new EPF-30P comes to you completely assembled and ready to operate. Carefully inspect
unit for any possible damage from transit.
When using the EPF-30P, note the directional airflow indicator on the external shell. This is the
way the air moves.
Prior to connecting the EPF-30P to the air supply line, inspect the inlet and outlet screen and
remove any debris that may restrict airflow movement.
WHEN USED WITH DUCTING
Do not install duct when fan is in operation.
FOR HAZARDOUS LOCATIONS
Use only "Static Conductive Hose" properly grounded.
If connecting duct to duct use only "Static Conductive" couplers made of aluminum.
Place duct lip over duct adapter and secure firmly.
Note the direction of airflow as indicated by the arrow on the side on the fan.
www.LarsonElectronics.com
EPF-30P
sales@larsonelectronics.com

Advertisement

loading

Summary of Contents for Larson Electronics EPF-30P

  • Page 1 When using the EPF-30P, note the directional airflow indicator on the external shell. This is the way the air moves.  Prior to connecting the EPF-30P to the air supply line, inspect the inlet and outlet screen and remove any debris that may restrict airflow movement. WHEN USED WITH DUCTING ...
  • Page 2 Larson Electronics LLC www.LarsonElectronics.com sales@larsonelectronics.com 9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364 SPECIFICATIONS DIMENSIONS Pneumatic Motor: 1.71 hp Height: 21” 53.34 cm RPM: 3000 Width: 14” 35.65 cm CFM: 2063 Length: 17” 43.18 cm Duct Adapter: 12”...