Eberle Design LMA-1200-120 Operating Instructions

Single channel – dual output – inductive loop vehicle detectors

Advertisement

1.

Connect to proper source voltage

Verify source voltage before applying power. The "Pin Assignment" side label indicates the input power required for each model and indicates either Fail Safe operation
or Fail Secure operation.
MODELS
12 VDC to 24 VDC or 24 VAC
LMA-1200-LV
LMA-1200-120
LMA-1200-240
LMA-1200S-LV
LMA-1200S-120
LMA-1200S-240
OUTPUT RELAY
POWER FAILURE
A
B
2.
DEFLECTOMETER
Indications
STATUS
0, 1, 2, 3, 4, 5, 6, 7, 8, 9
d
E
F
3.

LED Indications

STATUS
POWER LED
OFF
No Power
ON
Normal Power
2 Hz Flash
N/A
4 Hz Flash
N/A
1 Flash
Insufficient Line
Power
2 Flashes
N/A
3 Flashes
N/A
4.

Rear Panel DIP Switches and Rotary Switch

2-Position DIP Switch – Loop Frequency
SWITCH
1
2
Loop Frequency (DIPS 1 & 2) is controlled by the rear panel 2-Position DIP switch. On occasion, loops are placed in close proximity; it is necessary to select a different
frequency level for each loop to avoid loop interference (crosstalk). Four (4) frequencies are selectable, HIGH being the factory default. Press reset after changing sensitivity
setting.
8-Position DIP Switch - Detector Parameter Options
SWITCH
1
2
3
4
5
6
7
8
Extension Timing (Switches 4 & 5)
SWITCH
4
5
Output "B" Relay Configurations (Switches 6 & 7)
SWITCH
6
7
Operating Instructions
LMA-1200 "
Single Channel – Dual Output – Inductive Loop Vehicle Detectors
120 VAC
FAIL SAFE OPERATION
CALL Output
No Output
Sensitivity Meter (4, 5 & 6 = Optimum Sensitivity Setting for Loop & Lead-in Network)
OUTPUT A LED
Output OFF
Output ON
2-Second Delay Timing
0, 2, 5, or 10 Second
Extension Timing
"Real Time" Open Loop
"Real Time" Shorted Loop
"Real Time" 25% Inductance
Change
LO
MEDIUM – LO
ON
OFF
ON
ON
ON
Sensitivity Boost
Output A – Limited Presence
2-Second Delay Timing
See "Extension Timing" Table Below (Switches 4 & 5)
See "Output B Relay Configurations" Table Below (Switches 6 & 7)
0-Seconds
0FF
0FF
Pulse On Entry
0FF
0FF
DEFLECTOMETER
" Series
240 VAC
LOOP FAILURE
CALL Output
No Output
DEFLECTOMETER
2-Second Delay Timing
0, 2, 5 or 10 Second Extension Timing
Current "Real Time" Loop Failure
OUTPUT B LED
Output OFF
Output ON
2-Second Delay Timing
0, 2, 5, or 10 Second
Extension Timing
"Real Time" Open Loop
"Real Time" Shorted Loop
"Real Time" 25% Inductance
Change
MEDIUM – HIGH
ON
OFF
OFF
No Sensitivity Boost
Output A – Infinite Presence
No 2-Second Delay Timing
Reserved
2-Seconds
ON
OFF
Pulse On Exit
Presence (Duplicates Output A)
OFF
ON
Fail Safe
FAIL SECURE OPERATION
POWER FAILURE
No Output
No Output
LOOP FAULT LED
Loop Good
N/A
N/A
N/A
"Real Time" Open Loop if Outputs A & B are flashing.
"Prior" Open Loop if Outputs A & B are not flashing.
"Real Time" Shorted Loop if Outputs A & B are flashing.
"Prior" Shorted Loop if Outputs A & B are not flashing.
"Real Time" 25% Change In Inductance if Outputs A & B are flashing.
"Prior" 25% Change In Inductance if Outputs A & B are not flashing.
HIGH
OFF
OFF
5-Seconds
OFF
ON
ON
OFF
Fail Secure
LOOP FAILURE
No Output
No Output
FACTORY DEFAULT
OFF
OFF
FACTORY DEFAULT
OFF
OFF
OFF
OFF
OFF
OFF
OFF
N/A
10-Seconds
ON
ON
Fault Output
ON
ON
Rev. B – 09/18/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LMA-1200-120 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eberle Design LMA-1200-120

  • Page 1 Verify source voltage before applying power. The “Pin Assignment” side label indicates the input power required for each model and indicates either Fail Safe operation or Fail Secure operation. MODELS 12 VDC to 24 VDC or 24 VAC 120 VAC 240 VAC Fail Safe Fail Secure LMA-1200-LV LMA-1200-120 LMA-1200-240 LMA-1200S-LV LMA-1200S-120 LMA-1200S-240 FAIL SAFE OPERATION FAIL SECURE OPERATION OUTPUT RELAY POWER FAILURE...
  • Page 2 Operating Temperature: -30 F to 165 F (-34 C to +74 Pin Assignment (Connections): Model LMA-1200-LV Model LMA-1200-120 and LMA-1200-240 Function Function 12 VDC to 24 VDC / 24 VAC (+) AC Line DC Ground / 24 VAC (-) AC Neutral Output Relay “B”, Normally Open (Closes for DETECT)

This manual is also suitable for:

Lma-1200 deflectometer seriesLma-1200-lvLma-1200-240Lma-1200s-120Lma-1200s-240Lma-1200s-lv

Table of Contents