Silent extraction method

Advertisement

SEM7 MOTOR
The SEM7 motor is designed to exhaust fumes and
odours silently and effectively. It must be installed on an
external wall a minimum of 500mm from the ground and
connected to the rangehood.
Note: due to OHS regulations if the SEM7 motor is
positioned higher than 2 metres from the ground,
additional servicing costs may incur. Please note, motor
must be accessible for servicing.
Note: due to the noise of the motor itself once installed, be
sure to check that if it is located close to a boundary fence
or you are in a built up area that you have checked with
neighbours or local council regulations prior to installation.
Motor/ducting and electrical connection installation
Please note that the SEM7 motor must be installed at
a minimum distance of 2 metres from the outlet collar
on the rangehood. A maximum of 7 metres must not
under any circumstances be exceeded. All SEM7
motors come fitted with a 7metre long control cable.
1. The installation of the SEM7 motor must only be made
by a qualified technicial/tradesperson. Where possible
use a Sirius recommended installer. (See www.
siriusbrand.com for a list under the support tab)
2. After predetermining the location of the motor, make
sure you are within the recommendations above in
regards to min/max distances. Use the supplied drill
hole template that is supplied with the SEM7 motor
and drill support holes, paying careful attention to
make sure that the area behind is clear of electrical
cables and/or piping & plumbing. These holes are to
be drilled with an 8mm drill bit.
3. 210mm diameter hole to be cut into house for 200mm
ducting. Please note that if a solid masonary block wall
or brick wall is being used thaty a series of holes may
need to be drilled and then the remainder of the hole
be knock out by hand with a hammer and chisel. If a
masonary hole bit is available, this will provise the best
result.
4. A hole must also be made to contain the plastic pipe
that the SEM7 wiring loom is fed through. 40mm hole
is required. 40mm drill bit required.
5. Remove the stainless steel body to expose the motor
and fixing points by removing the external screws
located on the outside of the SEM7 motor. (Fig.4)
6. Run the length of semi-rigid/solid duct through the
pre-cut and attach to the SEM7 collar. Secure in
place with a URC-25/215 ring clamp, making sure it is
fastened tightly and will not come off. Feed the cable
from the motor though the 40mm plastic pipe at the
same time.
7. Lining up the fastening points with the pre-drilled holes
secure the motor in place using the supplied plastic
dowels and the supplied screws.
8. Replace the stainless steel body by following the
step 5 in reverse making sure that the holes line up
perfectly to ensure the unit is sealed correctly. Do not
silicone motor to the wall.
9. Run the length of ducting back to the location of
the rangehood and secure to the outlet collar on the
rangehood using anouther URC25-215 ring clamp.
10. Run the cable from the motor to the rangehood and
plug in the 6 pin plug to the top of the unit. There is a
2 pin plug that is the speed control that needs to be
plugged in also, removal of the red capped dummy
plug will expose the location. The motor must then
be earthed to the body of the rangehood using the
green andyellow cable by unscrewing on of the body
screw, connecting the earth wire to the rangehood by
tightening the screw back up.
11. The SEM7 motor will draw power directly from the
rangehood which needs to be plugged into a 10AMP
powerpoint located within 1 metre of the rangehood.
B
B
210mm
40mm
Screws
6
A
A
A
B
B
B
(Fig. 4)
A
A
(Fig. 3)

Advertisement

loading

This manual is also suitable for:

Sem2Sem7Sem8