NOTES:
Testing Cables for Pin-out Wiring Configuration (Cable Mapping):
DO NOT USE ON LIVE CIRCUITS
1. For testing local patch cables, connect the cable between the RJ45 sockets
located on sides of the tone generator and tone probe.
2. For testing installed cables, use a patch cable to connect the tone generator
into the jack at one end, and a patch cable to connect the tone probe
into the jack at the opposite end of the cable.
3. Set "tlk, cont, line/tone" switch on side of tone generator to the "cont" position.
4. Set the tone generator "slow, fast, off" switch on the mapper transmitter to
either the "slow" or "fast" position to scan through pins 1-8 and shield.
5. Read the lights for pins 1 through 8, and shield on the Tone Generator/
Cable-Check Transmitter and the Tone Probe/Cable-Check Receiver units to deter
mine connections through the cable. If one light on each end is shown, there is a
good connection between the respective pins. If a light appears on the Cable-Check
Transmitter and no lights appear on the Cable-Check Receiver, there is an open
contact between the respective connectors. If multiple lights appear on the trans
mitter or receiver at any one time, a short exists between respective contacts.
For the RJ11 6-wire systems, pins 1 and 8 are not shown. Pins 2 through 7 will
light up only whereas, light 2 equals pin 1 of the RJ11 cable and light 7
equals pin 6 of the RJll Cable.
Cable Mapping
Good 1-to-1
T.G.
Transmitter
T.P.
Receiver
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
Shield
Shield
Sample Test Results:
Remote Light Sequence
1 2 3 4 5 6 7 8 S
2 1 3 4 5 6 7 8 S
1 2 & 3 2 & 3 4 5 6 7 8 S
1 2 3 - 5 6 7 8 S
1 2 4 3 6 5 7 8 S
1 2 3 7 5 6 4 8 S
1 2 3 4 5 6 7 8 -
X 2 3 4 5 6 7 X
connectool Inc. - USA • Support: 800.272.8665 • Int'l 001.804.550.1121 • web: paladin-tools.com • 06/05
Paladin Tools
LAN & Telecom Cable Testing Kit
Cable Mapping
Cable Mapping
Cable Mapping
Cable Mapping
Cross 7-to-4
Short 1-to-2, 2-to-1
Open Pin 3
Open Pin 5
T.G.
Transmitter
T.P.
Receiver
T.G.
Transmitter
T.P.
Receiver
Transmitter
T.G.
Receiver
T.P.
T.G.
Transmitter
8
8
8
8
8
8
8
7
7
7
7
7
7
7
6
6
6
6
6
6
6
5
5
5
5
5
5
5
4
4
4
4
4
4
4
3
3
3
3
3
3
3
2
2
2
2
2
2
2
1
1
1
1
1
1
1
Shield
Shield
Shield
Shield
Shield
Shield
Shield
Cable Fault
None, cable wired correctly
Conductors 1 & 2 reversed
Conductors 2 & 3 are shorted
Conductor 4 is open
Pair 3/6 is transposed with pair 4/5
Conductors 4 & 7 are switched
Shield is open
RJ11 6-pin is wired directly
®

Operating Instructions

1573

Features and Benefits

• A complete test system for data and
telephone installations
• Applies distinct, selectable tone patterns
• Applies tone to balanced and unbalanced
circuits using dual (Tip & Ring) or single
(Tip) modes
• Tests line and load continuity
• Tests polarity of standard phone systems
• Red and black alligator clip-to-RJ11 cable
included
• Tone probe has adjustable volume control
• Cable mapper tests RJ45 and RJ11 local
patch cables & installed cables for
continuity including cross-over telephone
connections. Tests data and telephone
connection schemes
• Cable-check identifies opens, shorts, cross
connections, and good connections
• Tests UTP, STP, and flat satin cable types
with RJ45 connections.
• Two RJ45 shielded patch cords included
• Two 9-volt batteries included
• Auto-off battery save function
• Durable nylon carrying case with belt loop
included
• Two RJ11 patch cords included
Technical
Weight
18 oz. (complete kit)
T.P.
Receiver
8
7
Tone Generator
6
Dimensions
6.75" L x 1.35" W x 1.08" D
5
Output Voltage
8Vdc (open), 5Vdc (600Ω load)
4
Battery
9Vdc NEDA 1604, JIS 006P, IEC 6LR61
3
Battery life
120 hrs (NEDA 1604)
2
Auto-Off
1 hr (tone mode)
1
Output Frequency
8 tones: 523, 587, 659, 698, 784,
880, 988, 1046 HZ
Shield
Tone Sequences
4 patterns: single oscillating, dual
slow, dual fast & multi-tone
Connection
RJ11 6-pin modular plug
Tone Probe
Dimensions
5.92" L x 1.35" W x 1.08" D
Battery
9Vdc NEDA 1604, JIS 006P, IEC 6LR61
Battery life
120 hrs (NEDA 1604)
Tone Pick-up
Inductive type, non-conducting
Cable-Check
Cable Types
EIA/TIA-568A & B Cat-3 through
Cat-6, flat satin telephone, 4-pair
UTP/STP, 25-pair UTP/STP, 24/4
and 22/4 telephone line
Connection Types
RJ45 shielded (STP) or unshielded (UTP)
Output Signal
9Vdc nominal at 10mA max.
Voltage Protection
Connector pins protect up to 56Vdc
with 400Ω series resistance applied
for 2 minutes
Max. Cable Length
1650 feet (500 m)
Paladin Tools
LAN & Telecom Cable Testing Kit
Tone Tracing Note: the tone signal only emits from the top RJ11 socket.
Tone is NOT present on the side RJ45 socket
DO NOT USE ON LIVE CIRCUITS
1. For testing directly into RJ11 wall jacks, use an RJ11 patch cord wired 1-to-1
connection (provided). Connect the RJ11 patch cord into the top of the tone
generator in the RJ11 socket. (Proceed to step 4).
2. For testing telephone boxes, discreet wire connections, or open contact
connections install the alligator clip cable provided into the top of the tone
generator in the RJ11 socket. (Proceed to step 4).
3. To test RJ45 systems, use the RJ11-to-RJ11 patch cord provided to connect into
the top of the tone generator in the RJ11 socket. An RJ11 plug is compatible to
insert into most RJ45 sockets. The tone will be applied to the RJ45 two center
pins #4 and #5 respectively. In the event the RJ11 plugs on the patch cord is not
compatible with the RJ45 socket, use an RJ11-to-RJ45 adapter patch cable (not
provided) ensuring the two center pins for the RJ11 plug are mated to the
two center pins of the RJ45 plug, or use an 8-way RJ45 Modular Adapter (also
known as a "banjo") such as the Paladin Tools model 1902. (Modular Adapter
is not provided).
4. Set the "tlk, cont, line/tone" slide switch located on the side of the tone
generator to the "line/tone" position.
5. Press the "TONE" button to turn on the tone generator. Press the "TONE"
button to change operating modes. Indications are as follows:
Rev & Norm lights
Tone operation "ON"
Dual light
Tone applied to red (Tip) and black (Ring) alligator clips or to pins 3
(Ring) and 4 (Tip) or RJ11 plug
Single light
Tone applied to red alligator clip only (RJ11 socket pin 4 - Tip) with
n for grounded connections
black (RJ11 socket pin 3 - Ring) ope
Tone operation
Tone operation
Tone Operation
Tone operation
Tone Operation
Dual Mode
Single Mode
Dual Mode
Single Mode
Dual Mode
Reverse
Rev
Example: Light Indications
Normal
Norm
Dual
Dual
Single
Single
connectool Inc. - USA • Support: 800.272.8665 • Int'l 001.804.550.1121 • web: paladin-tools.com • 06/05
®
1573
RED
BLACK
Reverse
Rev
Normal
Norm
Dual
Dual
Single
Single

Advertisement

loading

Summary of Contents for Paladin Tools 1573

  • Page 1 RJ45 plug, or use an 8-way RJ45 Modular Adapter (also Battery 9Vdc NEDA 1604, JIS 006P, IEC 6LR61 Battery life 120 hrs (NEDA 1604) known as a “banjo”) such as the Paladin Tools model 1902. (Modular Adapter Auto-Off 1 hr (tone mode) is not provided). Output Frequency...
  • Page 2 RJ45 plug, or use an 8-way RJ45 Modular Adapter (also known 2. Connect the alligator clips so the tone generator is in series with the butt as a banjo) such as the Paladin Tools model 1902 (Modular Adapter is not provided). set at one end of the dead pair.