Download Print this page

ProFlo PF92250 Owner's Manual page 3

Submersible sump pumps

Advertisement

NOTICE
Height and/or piping restriction will reduce the pump output performance. See
the performance chart below to insure you have the proper pump for your application.
Whenever possible use the same size or larger pipe as the pump discharge for optimum
performance. Reducing the pipe size will not harm your pump; it will just reduce the output.
PERFORMANCE CHART
Output in gallons per minute at listed discharge
Model #
0'
PF92250, PF92251, PF92260
30
PF92330, PF92300PB,
40
PF92342
PF92331, PF92341
46
PF92351, PF92352
60
PF92501, PF92511
70
SPECIFICATIONS
PF92250
Model #
PF92251
PF92260
HP
1/4
1/4
Amps
3.8
3.8
Solids
1/8"
3/8"
Handling
Warranty
3
5
(Years)
Discharge
1 ¼" & 1
1 ½"
Size
½"
Power supply requirements
Motor
Liquid Temperature Range
***For continuous duty, the pump must be submerged to prevent overheating.
height above pumping level
5'
10'
15'
20'
22
20
16
9
34
28
22
12
36
30
25
12
56
50
35
15
66
58
48
25
PF92330
PF92331
PF92351
PF92330PB
PF92341
PF92352
PF92342
1/3
.3
1/3
4.1
4.1
7.6
1/8"
3/8"
1/2"
3
5
5
1 ¼" & 1 ½"
1 ½"
1 ½"
120V, 60 Hz (15 amp)
Continuous Duty***, Capacitor Start,
Thermally Protected
32° F - 120° F (0° C - 49° C)
6
DANGER
Do not use this pump to pump chemicals, flammable liquids, sewage or
corrosive liquids. You could injure yourself and the pump will fail. Pumping these types of
liquids voids the warranty. Make sure you purchase a pump designed for your specific needs.
This pump will handle fluids with the same characteristics as water
WARNING
Your pump has thermal over-load protection built in. It is not recommended for pumping
liquids over 120 F. The thermal overload protector will automatically shut down the pump in
an overheat situation. It will then reset itself once the pump cools down. This overload is
designed as a safety device and it will fail after repeated use. Normal operation is for fluids
25'
between 32 F & 120 F.
2
DO NOT RUN THE PUMP DRY. The pump depends on water for cooling and lubrication.
Operating the pump without water may cause the motor to overheat or cause damage to parts
2
of the pump. It may also shorten the life of your pump.
1
6
NOTICE
10
EXTENSION CORDS
For best performance, it is recommended to connect the power cord directly to the grounded
GFCI outlet. If the use of an extension cord is necessary, always use a grounded waterproof
type cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge.
PF92501
DANGER
Keep all electrical connections away from wet and moist environments. Wet
PF92511
connections can cause electrical shock resulting in personal injury.
1/2
WARNING
A
LWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO INSTALL
7.6
SERVICE OR PERFORM MAINTENANCE ON THE PUMP
1/2"
.
ELECTRICAL SHOCK
5
Your PROFLO Pump is designed and built to give you reliable performance and long life. It
will pump water automatically for years when properly installed in the right environment.
1 ½"
1.
Make sure power supply is disconnected.
2.
After the power is off, remove the old pump. There are many different possible
types of installations.
3.
It is best to remove all old piping and start over with new piping. Be sure to clean all
debris and dirt out of the sump basin before installing your new pump.
Be sure to have a grounded 120V AC outlet mounted within 6 ft. of your sump basin. Again, it
is highly recommended that a GFCI (ground fault circuit interrupter) outlet be installed in the
receptacle box.
NOTICE
A qualified electrician must perform all wiring.
USE AND INSTALLATION
.
FAILURE TO DO SO MAY RESULT IN FATAL
REMOVING OLD PUMP. (If necessary)
3
,

Advertisement

loading

This manual is also suitable for:

Pf92251Pf92260Pf92330Pf92330pbPf92331Pf92341 ... Show all