  • Page 1 ELITE ™ 2277 Redondo Ave, Signal Hill, CA 90755, USA Phone: (800) 603-4996 User Guide (562) 597-0102 Fax: (562) 597-0148 www.edgeforlife.com Made in the USA P/N: 19695-A Rev. 4/18/2016...
  • Page 2 Edge Systems products, including but not lim- ited to treatment media, - This page is intentionally left blank - serums and solutions, is a breach of the license - to only use any Edge Sys- tem device together with original Edge Systems products - and constitutes an infringement of IPRs.
  • Page 3: Table Of Contents

    APPENDICES CONTENTS HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® Contents Before You Start Introduction Safety Information Getting Started Package Contents Device Components Installation • Tool Holder • Waste Container • HydraFacial® Handpiece • HydroPeel® Tip •...
  • Page 4: Before You Start

    The procedure is soothing, refreshing, non-irritating and very eff ective. You can have the utmost confi dence in this leading-edge system manufactured in the USA by Edge Systems LLC. The HydraFacial MD® Elite™ may include other modes of operation in addition to the HydraFacial®...
  • Page 5: Safety Information

    APPENDICES BEFORE YOU START HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® SAFETY INFORMATION PRODUCT MARKING SYMBOLS Symbol Description Attention: Refer to accompanying documentation. Aufmerksamkeit: Beziehen Sie sich begleitend auf Dokumentation. Attention : Consultez la documentation d’accompagnement. Separate collection for electronic.
  • Page 6 7. I acknowledge that I have answered all questions truthfully and Garder au sec completely. _____(initial here) 8. I release Edge Systems, the ______________ (Aesthetician/Doctor), management and staff of_______________ (Clinic/Offi ce) from any and all liability associated with any injuries and/or current orfuture condi- tions resulting from the skincare procedures or products.
  • Page 7 City: ___________________________ State: ______ Zip: __________________ 2. Be sure to read the User Guide thoroughly before setting up the Email: ______________________________________________________________ system. If you experience mechanical and/or electrical diffi culties with your unit, call Edge Systems Service Department at 800-603- 4996. HydraFacial® BLUE/RED LIGHT THERAPY...
  • Page 8: Installation

    (incoming and outgoing) related L'équipement ne doit pas être utilisé dans un environnement riche en to the shipment of a System or parts to a Edge Systems approved and oxygène. designated repair facility for inspection and diagnosis for potential cov- erage under this warranty.
  • Page 9: Limited Warranty

    What Edge Systems Will Do: For the System, Edge Systems will, within the applicable warranty pe- riod, at Edge Systems ‘s sole option, repair or replace any defects in the This equipment has been designed and determined to be compliant with System without any costs to the Customer for parts or labor (except as regulatory agency limits for EMI.
  • Page 10 Tuch. Irgendeine Ersetzung kabelt Stored Restoring photos Ensure current photos in the system und Teile sollten direkt von Edge Systems LLC erlangt werden. Photos Are overrides current are backed up before restoring previ- Erased After photos stored in ous photos to the system.
  • Page 11: Skin Solutions

    être fait avec un chiff on propre, sec ou légèrement humide. Tout câble et “ON” position. toute pièce de rechange doivent être achetés directement auprès d’Edge If using only one station at a time, Systems LLC.
  • Page 12 If the equipment is damaged, notify ON/OFF switch and power cord, and Edge Systems at (800) 603-4996 or (562) 597-0102 and we will assist check that fuses are in good working you in the repair or replacement of your equipment.
  • Page 13 SYSTEM CLEANING GETTING STARTED HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® MECHANICAL LYMPHATIC DRAINAGE HANDPIECES Package Contents 1. Wipe off excess treatment lotion after each procedure. Console Unit 2. Clean the handpiece appropriately using cold sterilization or Wet (HydraFacial®) Handpiece Assembly autoclave following manufacturer's instructions.
  • Page 14 GETTING STARTED SYSTEM CLEANING HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® Options Device Components WET DIAMOND AGGRESSIVE ABRASION (MEDICAL USE ONLY) 1. It is always recommended to use gloves for this process. Touchscreen 2.
  • Page 15 SYSTEM CLEANING DGETTING STARTED HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® INSTALLATION Other WASTE CONTAINER TOOL HOLDER 1. Wash, dry, and wipe/spray germicide over waste canister and lid. 1. Loosen thumbscrews fi rst. Leave open overnight to air-dry.
  • Page 16 GETTING STARTED SYSTEM CLEANING HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® 5. When the brush and air cleaning are completed, make sure all the 5. Insert the gray cartridge into the handpiece. Align the arrow on the blue toggle switches are in the OFF position.
  • Page 17 SYSTEM CLEANING DGETTING STARTED HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® HydraFacial® Handpiece The HydraFacial® handpiece tubing chambers must be cleaned and dis- infected using the cleaning brush every week to prevent any bacterial contamination.
  • Page 18 3. Make sure that the Rinseaway™ system cleaning solution is properly installed. Only use the Edge System Rinseaway™ Solution;it is 1. Plug the metal tube coupling attached to the Dry Handpiece Tubing specifi cally developed to fl ush theough the tubing line to remove and into the port on the side of the machine.
  • Page 19 OPERATING INSTRUCTIONS DGETTING STARTED HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® ACTIVATE THE LED LIGHTS (OPTIONAL) UNIVERSAL TOOL HOLDER Refer to LED Light Therapy Handpiece User Guide part number 19692 for details on installation and operation. 1.
  • Page 20: Adjust Vacuum Strength

    OPERATING INSTRUCTIONS SOPERATING INSTRUCTIONS HYDRAFACIAL MD ELITE User Guide HYDRAFACIAL MD ELITE User Guide ™ ™ ® ® OPERATION TOUCHSCREEN OPERATION 1. Lightly tap the buttons displayed on the screen TURN ON THE SYSTEM with your fi ngertip (not fi ngernail). This will cause the unit to perform a variety of functions.