Assigning the IP address ................... 33 Password / Identification ................... 34 Maintenance / Servicing / Alterations ..............35 Repairs and Maintenance ..................35 Disposal / Recycling ....................35 Drawings ......................36 Notes ........................39 Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 2 von 40...
Page 3
Figure 7.1 – Axis IP Utility....................33 Figure.10.1 – Dimensions of the T08 ExCam IPQ1775 with K1 flange ......36 Figure 10.2 – Dimensions of the T08 ExCam IPQ1775 with K2 flange ......37 Figure 10.3 – Dimensions of the T08 ExCam IPQ1775 accessories ....... 38...
Page 4
March 20th, 2014 S.Seibert Compilation of the document September 9th, E.Schneider Modifications in Chapter 5.5.2 Digital unterschrieben von Steffen Seibert 2018 DN: cn=Steffen Seibert, o=SAMCON, ou, email=s.seibert@samcon.eu, c=DE Datum: 2018.09.06 13:01:14 +02'00' Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 4 von 40...
The ExCam IPQ1775 is suitable for the usage within the Ex zones 1, 2, 21, and 22 in- cluding the gas group IIC (all gases, steams, and fogs including acetylene, hydrogen, and carbon disulphide) and the dust group IIIC (conductive dusts and flammable fibrous material), as well as in mining.
Test report IECEx: DE/TUR/ExTR14.0026/00 Quality Assessment Report: DE/BVS/QAR14.0006/00 Maximum ambient temperature range relevant for explosion protection might deviate to the maximum functional temperature range. For maximum functional temperature range (MTBF) see chapter 2.12 Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 7 von 40...
Contact VS-08-RJ45-5-Q/IP20 etc. 10BASE-T/100BASE-TX PoE K version: 8x single pin twisted pair (solid conductor 0.64 mm , about 5 mm stripped) 1x shield (Cu braid 2.5 mm , ferules) 10BASE-T/ 100BASE-TX PoE Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 8 von 40...
Color: 0.23 lux, B/W: 0.05 lux Further cables available upon request, e.g. „Ölflex® Petro FD 865 CP“ (high resistance against oil and drilling liquids) or „XPLE Armoured 3 x 2.5“ (extremely robust, particularly designed for offshore environments) Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 9 von 40...
E-mail notification, HTTP and TCP, activation of external outlets; 96 MB pre and post alarm vid- eo buffering SD/ SDHC – internal slot for storage cards of Local storage: up to 64GB (16GB SDHC included in delivery scope) Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 10 von 40...
An electro-polished or powder-coated surface in various RAL colors (standard: RAL7035) is possible. Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 11 von 40...
Page 12
10 – technical drawings Dimensions camera housing T07 VA2.2 with wall mount bracket and roof (pointing forward) Additional media resistance as well as well as validation of chemical resistances possible upon request Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 12 von 40...
Safety guidelines Please observe the safety guidelines indicated in der EX installation manual of the T08 ExCam series! Illustration of the model key The following model options are currently available for the ExCam IPQ1775: Ex product name Model options Type...
Page 14
: -10 … +40 [°C] Normal ambient temperature range (MTBF): AMB_N : -30 … +40 [°C] Low ambient temperature range (MTBF): AMB_L : -60 … +40 [°C] LL = Lowest ambient temperature range (MTBF): AMB_LL Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 14 von 40...
Please observe the national regulations regarding security, installa- tion, and accident prevention (e.g. DIN EN 60079-14), as well as the safety guidelines described in this user manual and the EX installation manual! Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 15 von 40...
Connection table: Potential Color (IEC 60757) Profile Comment GN/YE 4 mm (fix) Screw terminal: Slotted screw M4 x 0.7 (DIN 84) with washer Ø 9 mm (DIN 125A) Table 6.1 – Potential equilization Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 16 von 40...
The green patch cable SKDxx disposes of 8(+1) conductors used for the data transfer with other network devices as well as to power the camera. In order to guarantee the power supply (Power Device, PD) of the ExCam IPQ1775 (power device, PD) a Power-over-Ethernet component (Power Sourcing Equipment, PSE) has to be available at the connecting side (e.g.
The T08 ExCam series supports both modes and the used power source (PSE) determines the mode. For executing a reboot, it is possible to separate the ExCam IPQ1775 from the network and to switch it on again while in operation or in interaction with a visualization system (hot plugging).
GND) Figure 6.7 – SKD01 Pin assignment In case the ExCam IPQ1775 is supplied via a PoE capable device, an additional safe- guarding of the power supply is not necessary. The power supply is executed by the PoE network device via an electronic with intelligent set-up. The camera as well as the con- nection is permanently monitored in order to avoid any failure or defects in case of a short-circuit fault.
(storage temperature) make sure to heat up the enclosure before switching on the camera circuit. For non-continuous systems please use an adequate time relay to switch on the heater, before the camera circuit is switched on! Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 21 von 40...
The booting process of the ExCam IPQ1775 may take up to one minute. Additional LEDs for checking network activities or the bandwidth are only visible when the housing is open.
Also, the camera is set to „wide“ range and the auto focus is deactivated. If desired, we customize the settings of the ExCam IPQ1775 to net ex- isting network and hardware requirements. Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 23 von 40...
5.5.2 Opening the pressure-resistant housing Opening the pressure resistant housing (DIN EN 60079-1: 2008) of the ExCam IPQ1775 is only allowed in case the SD storage card has to be removed or replaced or that a „Hardware Reset“ of the camera module is necessary.
In case the T08 ExCam IPQ1775 is equipped with a protection roof, it has to be removed first. To do so, loosen the four 8 mm lens head screws M4*0.7 at the front and back of the bracket (figure 6.10 and figure 6.11).
Beware not to damage the surface of bore hole and shaft (fit) at the flame proof gap preventing the transmission of ignition. Attention! Please make sure not to damage housing sealings and to keep them clean Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 26 von 40...
5.5.3 Removing / inserting an SD storage card The ExCam IPQ1775 can at a customers request be delivered with a 16GB SDHC stor- age card. Stored video files can be viewed or deleted via the web Interface and are also available on the download list (http://..).
5.5.4 Hardware Reset In order to reset all parameters, including the IP address, of the ExCam IPQ1775 to de- fault settings, a hardware reset has to be carried out. The parameters can be reset via the web surface or also manually. If the camera is not accessible in the network, the reset has to be carried out manually.
Control button Figure 6.15 – Control button LED status bar Figure 6.16 – Status display Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 29 von 40...
If the camera does not provide the anticipated results, steps 6.4.2 to 6.4.5 have to be repeated. For the fixed installation of the ExCam IPQ1775, either with a wall mount bracket, with a hinge attachment for sight-glass installations or for the optional installation of a roof, please observe the instructions of the EX installation manual! Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 30 von 40...
Page 31
The T08 ExCam series is certified to be also used for mobile applications (hand-held etc.) The cylinder head screws for the safe connection of the housing body and the flange have to be tightened with a torque of 3 Nm! Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 31 von 40...
JVM (J2SE) 1.5 or higher, or JRE (J2SE) 5.0 or higher. At delivery, the ExCam IPQ1775 is set to the applicable net frequency (50Hz or 60Hz). If the camera is used at a location with a differing net frequency, a flickering of the picture might be noticeable, particularly in surroundings with fluorescent tubes.
Assigning the IP address The ExCam IPQ1775 is an Ethernet network camera requiring an IP address to access it. Usually a DHCP server is integrated in most networks which automatically assigns an IP address. In case there is no DHCP server available in the network, the ExCam IPQ1775’s default address “192.168.0.90”...
Microsoft Inter- net Explorer or Mozilla Firefox (administrator rights are required) The page „Live View“ of the ExCam IPQ1775 is now displayed. With the setup link it is possible to open the menu options to allow personal camera settings...
Repairs and Maintenance Repairs must only be carried out with original parts of SAMCON Prozessleittechnik GmbH. Damaged pressure-resistant housings have to be replaced completely. If in doubt, return the applicable part to SAMCON Prozessleittechnik GmbH.
Drawings T08-VA2.2.K1.BOR-C-XXX-X-LL (housing) Figure.10.1 – Dimensions of the T08 ExCam IPQ1775 with K1 flange Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 36 von 40...
T08-VA2.2.K2.BOR-B-XXX-X-N (housing) Figure 10.2 – Dimensions of the T08 ExCam IPQ1775 with K2 flange Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 37 von 40...
T08-VA2.2.K1.BOR-C-XXX-X-LL (accessories) Figure 10.3 – Dimensions of the T08 ExCam IPQ1775 accessories Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 38 von 40...
Need help?
Do you have a question about the ExCam IPQ1775 and is the answer not in the manual?
Questions and answers