Gemco 958 Series Installation Manual

Embedded ldt embedded linear displacement transducer

Advertisement

Quick Links

Series 958 Embedded LDT
Embedded Linear Displacement Transducer
Installation Manual
958A
ABSOLUTE PROCESS CONTROL
KNOW WHERE YOU ARE... REGARDLESS

Advertisement

Table of Contents
loading

Summary of Contents for Gemco 958 Series

  • Page 1 Series 958 Embedded LDT Embedded Linear Displacement Transducer Installation Manual 958A ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS...
  • Page 2: Table Of Contents

    Contents Chapter 1: 958A Overview ..................3 1.1 Dimension Drawing ..................... 4 Chapter 2: Installation ....................5 2.1 Installing in a Hydraulic Cylinder ..............5 2.2 Magnet Installation ..................... 5 2.3 Mounting ......................6 2.4 Set Screw Installation ..................6 Chapter 3: Connections &...
  • Page 3: Chapter 1: 958A Overview

    Installation Manual Chapter 1: 958A Overview We know today’s industrial challenges are extreme, so we designed and built a sensor to meet and exceed these demands, regardless of the application or environment. Innovation, proprietary technology and decades of experience were the key to the development of our 958A Embedded Linear Displacement Transducer. The 958A was designed with the mobile hydraulics market in mind.
  • Page 4: Dimension Drawing

    Series 958 Embedded Linear Displacement Transducer 1.1: 958A Dimension Drawing 0.98 (25.0) 0.78 (19.8) 958A 800-835-0290 Clemson, MI +PWR 48017 U.S.A. SETIN AGND Ø .13 PART No: 958a-V0-100-E-A-C10X SERIAL No: XXXXXXXXXXXX (3.2) www.ametekfactoryautomation.com M12 (A CODE) FIELD INSTALLABLE RECEPTICLE Ø 1.89 (48.0) CONNECTOR Ø...
  • Page 5: Chapter 2: Installation

    Installation Manual Chapter 2: Installing the LDT The 958A is designed for insertion into mobile hydraulic and clevis style cylinders. The hydraulic cylinder must be prepped for an Embedded Style Linear Transducer. Installation Notes: The 958A is offered in either a 10.29mm (.405") or an 8mm (.315) diameter guide tube. There are 4 different magnet styles offered.
  • Page 6: Mounting

    Series 958 Embedded Linear Displacement Transducer 2.3: Mounting There are 4 basis steps to install LDT into cylinder. During assembly of the cylinder install LDT Route cable or M12 connector through cylinder Install Set screws to hold LDT in place (M5x10 max.), 3 set screws recommended at 120°. torque 0.05Nm 1.89 See Figure 2-4 Set Screw Channel Detail [48]...
  • Page 7: Chapter 3: Connections & Wiring

    Installation Manual Chapter 3: Connections and Wiring Once the LDT has been installed, wiring connections can be made. Units are available with Integral cable assemblies, bare leads or 5 pin M12 (A-Code) connector options. Refer to part numbering on unit in question for proper wiring.
  • Page 8: Pinouts And Wiring

    958A Supply Power Position Supply Common Common 8-30 VDC - Input Program Input Series 958 Embedded Linear Displacement Transducer 958A LDT 958A LDT Linear Displaceme Linear Displaceme 958A LDT Linear Displaceme Position Customer Position Customer Output Supplied Power Output Supplied Power + Input + Input Power...
  • Page 9: Features - Automation Gain Control

    Installation Manual 3.3: Features Automatic Gain Control The Automatic Gain Control feature will automatically search and find the magnet on power up and adjust the signal strength to the optimum setting. If power is applied without a magnet on the LDT, the LDT will go into a fault condition and transmit a voltage or current outside of the programmed range.
  • Page 10: Appendix A: Part Numbering

    Available lengths are 60 and 250 mm. There are 4 magnet choices available for the 958 Series. Magnets and magnet spacers must be ordered as M12–5 Pin (A Code)–Field installable–Pin assignment 1-2-3 (**) ..M_S1 Available lengths are 60 and 250 mm.
  • Page 11: Appendix B: Specifications

    Installation Manual Appendix B: Specifications General Specifications Displacement 2" to 100" (50mm to 2540mm) in .1" or 5mm increments Performance Specifications - Measurement Linearity +/-0.04% of Span or +/-0.008", whichever is greater Hysteresis 0.001" maximum Repeatability Equal to Resolution of output signal, +/-0.01% of Span or 0.001", whichever is greater Update Time 0.5 ms minimum, proportional to length of LDT - not to exceed 4ms...
  • Page 12 Series 958 Embedded Linear Displacement Transducer Protection Polarity Reverse polarity protected Overvoltage Transient overvoltage protection to +33VDC Output Resolution 0 to 10VDC 16 bits (0.0015% of span) 0 to 5VDC 15 bits (0.0031% of span) 0.25 to +4.75VDC ~15 bits (0.0034% of span) 0.5 to +4.5VDC ~15 bits (0.0034% of span) 4 to 20mA...
  • Page 13 953 VMAX LDT 955 BRIK • Shock resistant to 1000Gs • Low profile LDT • Vibration resistant to 30Gs • Analog output 4-20mA, 0-10 VDC, • Analog outputs, 0-10 VDC, +/-10 +/-10 VDC, digital and quadrature outputs VDC, 0-5 VDC, +/-5 VDC, 4-20mA •...

This manual is also suitable for:

958a