Standard weatherproof electromagnetic lock

Advertisement

Optional Bracket
Brackets installation are according to door swing direction and door frame type , e.g. narrow frame door , frameless glass door , inswing door , etc.
Regular Installation
(outswing door)
Regular Installation
1
Tem pl ate
2
3
4
Armature Plate
Hollow Metal Door
Outdoor
Outdoor
12.7mm
8mm
6.8mm for M8-1.25 thread
Drill a
Ø8mm hole through
Drill a
d o o r, o n c l o s i n g s i d e
and tap on closing side
enlarge to Ø12.7mm by a
a M8x12.5 thread.
sexnut blot on the opening
side.
Recommendation:
(300 LBS), maximum thickness of door is 44 mm.
(600 LBS), maximum thickness of door is 50 mm.
(800 LBS), maximum thickness of door is 48 mm.
(1200 LBS), maximum thickness of door is 46 mm.
L-bracket for
narrow frames (optional)
Fold the mounting template 90°
Place the tamplate to the proper
position of the door and frame .Mark
the hole positions of the template to
the door and frame
Drill the holes according to the
marks.
Please install the armature plate as
illustrated here. (Dimensions of the
holes are depending on the door
types as illustrated below.)
Reinforced Door
Solid Door
36mm
Outdoor
12.7mm
8mm
Ø6.8mm hole
Drill a Ø8mm hole thrugh
d o o r o n c l o s i n g s i d e
enlarge to Ø 12.7mm, by a
sexnut blot on the opening
side. The depth is 36mm.
U-bracket for frameless
glass doors (optional)
5
6
9.4mm holes for M6 Blind Nuts.
7mm holes for M5 Blind Nuts.
7
Fixing screw
Power
8
Outswing
Holding Force
Butt Splice(IDC) Connector
Using crimper or pliers and pressing the header of connector
down to even position.
LZ-bracket for
inswing doors (optional)
Fasten the mounting plate with the
mounting screws. The position of the
mounting plate should be adjustable.
Use the screws to permanently
mount the mounting plate, then
mount the magnet with the fixing
screws provided.
Connect the power and test the unit.
Insert the anti-tamper caps into the
holes of mounting screws.