Download Print this page

C-MORE EA9 Series Quick Start Manual

Advertisement

Quick Links

®
3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860
C-more EA9 Series Touch Panels
Quick Start Guide
Quick Start Guide
Quick Start Guide
Safety Information
WARNING: To minimize the risk of potential safety problems, you should follow
all applicable local and national codes that regulate the installation and operation
of your equipment. These codes vary from area to area and it is your responsibility to
determine which codes should be followed, and to verify that the equipment,
installation, and operation are in compliance with the latest revision of these codes.
Equipment damage or serious injury to personnel can result from the failure to follow
all applicable codes and standards. We do not guarantee the products described in this
publication are suitable for your particular application, nor do we assume any
responsibility for your product design, installation, or operation.
If you have any questions concerning the installation or operation of this
equipment, or if you need additional information, please call technical support at
1-800-633-0405 or 770-844-4200.
This publication is based on information available at the time it was printed. At
Automationdirect.com® we constantly strive to improve our products and services, so we
reserve the right to make changes to the products and/or publications at any time without
notice and without obligation. This publication may also discuss features that may not be
available in certain revisions of the product.
ADVERTISSEMENT: Afin de réduire au minimum le risque d'éventuels problèmes
de sécurité, vous devez respecter tous les codes locaux et nationaux applicables régissant
l'installation et le fonctionnement de votre équipement. Ces codes diffèrent d'une région
à l'autre et, habituellement, évoluent au fil du temps. Il vous incombe de déterminer les
codes à respecter et de vous assurer que l'équipement, l'installation et le fonctionnement
sont conformes aux exigences de la version la plus récente de ces codes.
L'omission de respecter la totalité des codes et des normes applicables peut entraîner des
dommages à l'équipement ou causer de graves blessures au personnel. Nous ne garantissons
pas que les produits décrits dans cette publication conviennent à votre application particulière
et nous n'assumons aucune responsabilité à l'égard de la conception, de l'installation ou du
fonctionnement de votre produit.
Si vous avez des questions au sujet de l'installation ou du fonctionnement de cet
équipement, ou encore si vous avez besoin de renseignements supplémentaires, n'hésitez
pas à nous téléphoner au 770-844-4200.
Cette publication s'appuie sur l'information qui était disponible au moment de l'impression.
À la société AutomationDirect, nous nous efforçons constamment d'améliorer nos produits
et services. C'est pourquoi nous nous réservons le droit d'apporter des modifications aux
produits ou aux publications en tout temps, sans préavis ni quelque obligation que ce soit.
La présente publication peut aussi porter sur des caractéristiques susceptibles de ne pas être
offertes dans certaines versions révisées du produit.
If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Before you begin...
Minimum items required to create a working system:
• C-more EA9 Touch Panel - 6", 7" wide, 8", 10", 12" or 15" model
• C-more Programming Software, p/n EA9-PGMSW
• Personal computer - to run the C-more programming software
• C-more USB Programming Cable, p/n USB-CBL-AB15 or Ethernet connectivity between PC and
Touch Panel
• Power source: C-more AC/DC Power Adapter, p/n EA-AC or a dedicated 12-24 VDC
switching power supply
• Communications Cable (serial or Ethernet) – to connect the C-more Touch Panel to your
controller
Copyright 2016, Automationdirect.com Incorporated/All Rights Reserved Worldwide
1
Unpack and Inspect
Inspect all equipment for completeness. If anything is missing or damaged,
immediately call the AutomationDirect® returns department @ 1-800-633-0405.
Quick Start
Guide
Cutout Template*
C-more Panel
Gasket
DC power connector
Mounting Clips
Logo Label*
*Not included with EA9-T7CL-R and EA9-T7CL.
2
Install Optional Hardware Accessories
EA-COMCON-3A or
EA-AC
EA-COMCON-3
AC / DC Power Adapter
DSUB Port Adapter
C-more Touch
Panel
USB-FLASH
USB Pen Drive
3
Available Communication Ports
Port 2
Serial Communication
RS-485
+
Logic Ground
SD Card Slot 1
Port 3
RJ12 Serial Communication
RS-232C
Pin
Signal
1
0V
1
6
2
N.C.
3
RXD
4
TXD
Pin
1
5
Supplies +5VDC
6
0V
2
3
4
Shell
Port 1
PLC Serial Communications
RS-232C / RS-485
USB Port - Type A
Ethernet 10/100 Base-T
USB Device Options
PLC Communications,
8
1
Programming/Download
Pin
Pin
Signal
Pin
Signal
15
9
1
Vbus
1
TD+
5
do not use
2
D–
Pin
Signal
Pin
Signal
Pin
Signal
2
TD–
6
RD–
1
Frame GND
6
LE (for DH485)
11 TXD+ (422/485)
3
D+
3
RD+
7
N.C.
4
GND
2
TXD (232C)
7
CTS (232C)
12
TXD– (422/485)
4
do not use
8
N.C.
SHELL
Shield
3
RXD (232C)
8
RTS (232C)
13
Term. Resistor
Link Status LED (Green)
VCC
Network Speed LED (Yellow)
4
9
RXD+ (422/485)
14
N.C.
(Supplies +5VDC)
On Ethernet Linked
On
100M
5
Logic GND
10 RXD– (422/485)
15 N.C.
Off
No Ethernet Comm.
Off
10M
Blinking
1
8
Comm. Activity
Green
Note: Device is not available on Base Feature touch panel EA9-T6CL-R
Note: Device is not available on Base Feature touch panel EA9-T7CL-R
Note: Device is only available on touch panels EA9-T12CL and EA9-T15CL.
4
Install the Software and Develop a project
• Purchase the C-more programming software, EA9-PGMSW at
AutomationDirect.com. EA9-PGMSW is available on CD or by
download.
• Install EA9-PGMSW on your PC.
• Use the software to create a project.
• Download the project to the C-more panel from the software via
Ethernet or USB cable or on USB memory or SD card
Notes regarding Ethernet access to a C-more panel.
If you intend to take advantage of the methods of remote access to the panel, including the web server, PC
remote access, FTP, iPhone, iPad or Android app, you need to consider the security exposure in order to mini-
mize the risks to your process and your C-more panel.
Security measures may include password protection, changing the ports exposed on your network, including a
VPN in your network, and other methods. Security should always be carefully evaluated for each installation.
5
Connect C-more Panel to Computer
• Connect a USB Programming Cable, such as p/n USB-CBL-AB15, from a USB type A
port on the PC to the USB type B programming port on the C-more touch panel
• or connect the C-more touch panel and PC together either directly or via an Ethernet
switch, and CAT5 Ethernet cables (full feature panels only)
PC
Touch Panel
USB
Port
USB
USB-CBL-ABxx
Port
USB Cable
USB
PC
Ethernet
Port
EA-x-COV2
Screen
Protector
PC
C-more
Touch Panel
Ethernet
Port
Ethernet CAT5
Cable
EA-SD-CARD
SD Card
Auto MDI / MDI-X
Ethernet Port
Ethernet
via Cable
6
Provide Power to C-more Panel
Wire a dedicated 12-24 VDC power source to the DC connector on the rear
of the C-more touch panel, include wiring the ground terminal to a proper
equipment ground. The recommended power supply is AutomationDirect
p/n: PSC24-060
• or install a C-more AC/DC Power Adapter, p/n EA-AC, to the rear of the touch panel and
wire an AC voltage source of 100-240 VAC, 50/60 Hertz, to its AC connector
• then turn on the power source and check the LED status indicators on the front and rear of
the C-more touch panel for proper indication
AC Wiring
SD Card Slot 2
Recommended AC Supply Fuse
3.0A time delay, ADC p/n: MDL3
USB Port - Type B
Programming
L
Signal
100 - 240 VAC
N.C.
2
1
50 / 60 Hz
D–
3
4
N
D+
GND
G
Shield
CPU Status LED (Green, Orange & Red)
Off
Power Off
Green
Normal - CPU Run State
HDMI Port Video Out
Red
Memory Error
Blinking Red
Watchdog Timer Error
Blinking Orange
OS Error
Blinking Green
Power Loss Detection
Power LED (Front of Panel)
Signal
Color
On
Off
Green
Power On
Power Error
Power Specifications
Model
EA9-T6CL-R
EA9-T6CL
EA9-T7CL-R
EA9-T7CL
Specification
16.0W
Power Consumption
1.30A @ 12 VDC
0.66A @ 24 VDC
Internal Fuse
4.0A
(non-replaceable)
7
Access the C-more Panel Setup Screens
• Access the Main Menu of the touch panel setup screens by pressing the extreme upper left
corner of the panel display area for three (3) seconds as shown below.
• Adjust the time and date for the panel by pressing the Setting button on the Main Menu,
then press the Adjust Clock button on the Setting screen.
• Use the right pointing arrows for the time or date display to select the unit to change.
Use the up and down arrows to increment or decrement the value for the selected unit.
• Press OK when done to accept the changes to the time and date that is retained in he
touch panel's battery backed memory, or press Cancel to exit the Adjust Clock setup screen
without making any changes.
• Press the Main Menu button on the Setting screen and then the Exit button on the Main
Menu screen to return to the application screen.
C-more
Stride™
Ethernet Switch
10/100 Base-T
(such as SE-SW5U)
C-more
Touch Panel
Ethernet CAT5
Auto MDI / MDI-X
Cable
8
Ethernet Port
Ethernet
Connect the C-more Panel to a PLC
via Switch
• Connect the serial communications cable between the C-more touch panel and the PLC
• or connect the C-more touch panel and PLC together via an Ethernet switch and Ethernet
cables (full feature panels only)
• or use an Ethernet cable directly between the C-more Ethernet port and the PLC Ethernet
port (full feature panels only)
Ethernet
H0-ECOM/H0-ECOMM100
Ethernet Module
EA-AC Tightening Torque
Power supply cable torque
71 - 85 oz-in (0.5 - 0.6 Nm)
DL06 PLC
Ethernet CAT5
Power connector mounting torque
71 - 85 oz-in (0.5 - 0.6 Nm)
Mounting flange screw torque
57 - 71 oz-in (0.4 - 0.5 Nm)
DC-CON Tightening Torque
Power connector screw torque
70.4 oz-in (0.5 Nm)
Power connector mounting torque
56 oz-in (0.4 Nm)
Use 60 / 75°C copper conductors only, 12 - 24 AWG
DC Wiring
H0-ECOM/H0-ECOM100
Ethernet Module
Recommended DC Supply Fuse
Panel Size
Rating
ADC p/n
6" – 10"
2.5 A
MDL2-5
12" & 15"
4.0 A
MDL4
+
DL06 PLC
12-24 VDC
GND
Additional Help and Support
Equipment
Ground
• For product support, specifications, and installation troubleshooting, a Hardware User
NOTE: Use 60 / 75 °C copper conductors only,
Manual can be downloaded from the On-line Documentation area of the AutomationDirect
12 - 24 AWG
Web site
• For software programming help, refer to the C-more Programming Software on-line
embedded help.
• Refer to demos of the product at: http://c-more.automationdirect.com/software/software_
EA9-T8CL
EA9-T10CL
EA9-T12CL
EA9-T15CL
demo.html
18.0W
18.0W
21.0W
29.0W
• For additional technical support and questions, call our Technical Support team @
1.50A @ 12 VDC
1.50A @ 12 VDC
1.75A @ 12 VDC
2.40A @ 12 VDC
1-800-633-0405 or 770-844-4200.
0.75A @ 24 VDC
0.75A @ 24 VDC
0.88A @ 24 VDC
1.20A @ 24 VDC
6.3A
Serial
C-more
Touch Panel
DL-06 PLC
EA-2CBL-1
Port 2
Port 1
C-more
Touch Panel
Auto MDI / MDI-X
Cable
Ethernet Port
Ethernet
Stride™
via Switch
Ethernet Switch
10/100 Base-T
(such as SE-SW5U)
C-more
Touch Panel
Ethernet CAT5
Cable
Auto MDI / MDI-X
Ethernet Port
Data Sheet: EA9-QSG Rev. D

Advertisement

loading

Summary of Contents for C-MORE EA9 Series

  • Page 1 Ethernet sont conformes aux exigences de la version la plus récente de ces codes. Available Communication Ports • or install a C-more AC/DC Power Adapter, p/n EA-AC, to the rear of the touch panel and H0-ECOM/H0-ECOMM100 C-more L’omission de respecter la totalité des codes et des normes applicables peut entraîner des...
  • Page 2 Specifications C-more Panel Dimensions Panel Dimensions Specifications Model Model 6” TFT color w/ 6” TFT color w/ 7” TFT color w/ 7” TFT color w/ 8” TFT color w/ 10” TFT color w/ 12” TFT color w/ 15” TFT color w/...

This manual is also suitable for:

Ea9-t6cl-rEa9-t6clEa9-t8clEa9-t10clEa9-t12clEa9-t15cl ... Show all