Do you have a question about the SD Series and is the answer not in the manual?
Questions and answers
Summary of Contents for Aichi SD Series
Page 1
1,6 m Dry Dial Register, Direct Reading in Cubic Meters / Liters Instruction Manual Thank you very much for purchasing Aichi’ s water meter “ SD Series.” • Before using the device, please read this instruction manual for correct use.
Table of Contents 1. Features of SD Series ……………………………… 2. For safe use …………………………………………… 3. Please keep the followings for your safety …… 4. Name of each part …………………………………… 5. To transport and store the meter ………………… 6. When piping and installing …………………………...
1. Features of SD Series •Clear Display Meter reading figures are enlarged by 70% for easier reading. Also, the indication mechanism is in the sealed capsule so as to maintain a clear display. •Adjustable Display Display part can be rotated to an easy to see position. It can be rotated after installation, so it can be mounted in any piping direction.
3. Please keep the followings for your safety. Caution Do not drop the meter. Do not drop or impact the meter strongly. Doing so may result in injury or damage the meter. Always wear gloves when performing installation work. Your fingers may be caught or cut by the bolt threads if gloves are not worn. Never get on the meter.
4. Name of each part Display Digit Wheel Cover Rotation indicator (Tell-tale indicator) Indicator Marking Bottom Case Aichi tokei Name of manufacturer Model Type =1,6 Permanent Flowrate R100 Measurement Range Q Meter must be installed in the horizontal position 5. To transport and store the meter Do not impact it.
6. When piping and installing Select an installation site satisfying the following criteria. Select a place where the meter can be installed horizontally. Install the meter as low as possible at the piping, and select a place where air does not mix in or remain in the meter.
Be sure to install the meter horizontally without no tilt to either side and align the arrow with the flow direction. (Refer to the figures below.) Marking indicating the flow direction Correct installation method Incorrect installation method Provide a straight piping area, which is more than 3 times as long as the diameter up stream from the meter.
8. Explanation of indication (1) As for the m scale (charge scale), read the indicated number as is. (L scale is indicated in red figures.) (2) The 100L or less is used for inspection and testing. The 10L、1L and 0,1L scales are analog type (dial type). Read each point from the largest digit to the smallest digit in a way similar to reading the clock hands on the dial of a clock.
9. Caution The manufacturer shall have no responsibility for the damage or failure under the following conditions: Product is damaged due to physical abuse, mishandling, accident, negligence or failure to follow the catalog, specification sheet, instruction manual from the manufacturer. Product is damaged by act of God such as fire, earthquake, storm and flood, lightning, vandalism or criminals or other conditions beyond the control of the manufacturer.