Summary of Contents for Donaldson UFM-T100H

  • Page 1 UFM-T100H...
  • Page 3 Power Alarm Test Power Alarm Test Power Alarm Test max 40 psi...
  • Page 4: Programmer Connection

    Programmer connection View on plug View on socket Alarm connection (potential free contact) Potential free contact max. 48V DC-relay Diode-suppressor max. 92 mA Potential free contact max. 230V AC-relay Interference-protection condenser 47 nF - 100 nF (suitable voltage) max. 92 mA...
  • Page 5: Warranty

    6 ... 10 Warranty...
  • Page 6: Functional Elements

    Functional elements For your saftey Cover screws Pozidrive 1; 0.74 ft lbf Cover with heater You as operator / user of the unit should Light On: make yourself familiar with the function, Light Flashing: Error installation and start-up of the unit through these operation instructions.
  • Page 7 Appropiate use After installation the isolation must be The unit may only be used for its intended mounted (4). purpose. These units are intended exclusively for following purpose: Ensure that no water pockets are formed in the piping (5). Trapped air Draining condensate from prevents the condensate from flowing compressed air out compressors, air...
  • Page 8 Notes for electrical connection In the heater are line resistance are installed, that gives out heat. The heat is transfer by the conducted Strip the insulation off 6 inches of the heater on the aluminium housing. cable. The control of the heater with The unit only operates when power is temperature sensors is integrated.
  • Page 9: Technical Data

    Informationes concerning If the error occurs again, it is essential to maintenance doubt, please contact our after sales service section. Technical Data The unit requires very little maintenance. Parts subject to wear Operating Pressure: 12 - 250 psi should be replaced at least every year.
  • Page 10: Spare Parts

    Accessories Spare parts Set of replacement Screwed connection with parts subject to 1“ – 3/4“ union nut wear Outlet adapter Screwed connection with ball valve Please state in all cases the type designation of the condensate drain when ordering spare parts. Programmer Please state in all cases the type Dimensions...
  • Page 11 Such a refund will be the full extent of Donaldson Company, Inc’s. liability. Donaldson Company, Inc. shall not be liable for any other costs, expenses or damages whether direct, indirect, special, incidental, consequential or otherwise.
  • Page 12 Technical alterations reserved! Sous réserve de modifications technicques Alteraciones técnicas reservadas Donaldson Company, Inc. Compressed Air & Gas P.O. Box 1299 Minneapolis, MN 55440-1299 U.S.A Tel 800.543.3634 Fax 770-448-3854 www.donaldson.com...