Icare Tonovet Plus Quick Manual

No anesthesia no calibration
Hide thumbs Also See for Tonovet Plus:

Advertisement

Quick Links

QUICK GUIDE
ENGLISH

Advertisement

loading

Summary of Contents for Icare Tonovet Plus

  • Page 1 QUICK GUIDE ENGLISH...
  • Page 2 TURNING THE TONOMETER ON AND LOADING THE PROBE Press the Select or Measure button to turn the tonometer on. Illustrations of these alternative ways of starting: Remember to use the wrist strap Pressing the Select button Pressing the Measure button Open the probe tube by removing the cap and insert the probe into the probe base as shown in the image. When the Play symbol appears on the display, the tonometer will be ready for measurements To change the setting for different species press the Select button to access the menu. Press Navigation buttons and select SETTING by pressing the Select button. Toggle the settings by Navigation buttons and select a specie setting by pressing Select button. To measure return to MEASURE by navigation buttons.
  • Page 3 Icare TONOVET Plus tonometer Quick Guide ENGLISH Keep the probe horizontal and pointing perpendicularly to the center of the cornea. The distance from the tip of the probe to the patient´s cornea should be 4 - 8 mm (5/32 - 5/16 inch). The probe base light must be green (indicating correct measuring position). Green probe base light indication Press the Measure button to measure IOP.
  • Page 4 PARTS OF THE TONOMETER Measuring support adjusting wheel Display Measure button Select button Measuring support Probe base and probe base light Collar Navigation buttons CHANGE/CLEAN THE PROBE BASE REGULARLY TO AVOID UNNECESSARY SERVICE. CLEANING THE PROBE BASE Replace the probe base every 12 months. Clean the probe base every 6 months. Clean or replace the probe base if the error message Clean Change is displayed. Make sure that the probe base is completely dry before using it. • Fill the probe base cleaning container or other clean container with 70-100 % isopropyl alcohol. • Turn the power off. • Unscrew the probe base collar and remove the probe base by tilting the tonometer downwards. • Insert the probe base into the probe base cleaning container or other clean container filled with 70-100% isopropyl alcohol. • Let soak for 5-30 minutes. • Remove the probe base from alcohol. • Dry the probe base by blowing clean canned or compressed air into the hole in the probe base. This will additionally remove possible residual dirt. • Insert the probe base into the tonometer.