Gilson MD-2000F Operating Manual

Micro-deval apparatus

Advertisement

Quick Links

OPERATING MANUAL
Micro-Deval Apparatus
MD-2000, MD-2000C & MD-2000F
Rev: 07/17/2017
PHONE: 800-444-1508
FAX:
P.O. Box 200, Lewis Center, Ohio 43035-0200
800-255-5314
740-548-7298
E-mail: customerservice@gilsonco.com
Website: www.globalgilson.com
740-548-5314

Advertisement

Table of Contents
loading

Summary of Contents for Gilson MD-2000F

  • Page 1 OPERATING MANUAL Micro-Deval Apparatus MD-2000, MD-2000C & MD-2000F Rev: 07/17/2017 PHONE: 800-444-1508 FAX: P.O. Box 200, Lewis Center, Ohio 43035-0200 800-255-5314 740-548-7298 E-mail: customerservice@gilsonco.com Website: www.globalgilson.com 740-548-5314...
  • Page 2: Table Of Contents

    Gilson Company, Inc. Micro-Deval Apparatus: MD-2000, MD-2000C & MD-2000F TABLE OF CONTENTS Page Table of Contents Introduction Theory of Operation Principle of Operation Unpacking & Set-Up Controller Operation Mode Selection Initial Function Check Operating Instructions Performing a Test Maintenance Routine Cleaning...
  • Page 3: Introduction

    ASTM Designation D 7428 and Ontario LS-619. Location must allow the free flow of air through the louvers located on both sides of the case. The MD-2000F model 3.0 PRINCIPLE OF OPERATION: features a cooling fan located in the rear panel to draw additional air through the louvers.
  • Page 4: Controller Operation

    Gilson Company, Inc. Micro-Deval Apparatus: MD-2000, MD-2000C & MD-2000F Cabinet doors are equipped with safety interlock (see Once the timer or counter mode of operation is selected, Figure 1) which will not allow operation of the MD-2000 that mode becomes the default method of operation until unless both doors are properly closed.
  • Page 5 Gilson Company, Inc. Micro-Deval Apparatus: MD-2000, MD-2000C & MD-2000F digits to tens, hundreds, then thousands. Once the desired RPM Screen: Displayed when <A> is pressed from either value is displayed, press <OK> again to enter the new value. the Timer Mode or Counter Mode screens. Revolutions The next two lines are current revolutions for the top and counted during the last full minute are shown.
  • Page 6: Initial Function Check

    • If a jar leaks, inspect the seal surface for debris, warpage or damaged gasket. If watertight seal cannot be established, contact Gilson – DO NOT use the jar. • After watertight seal is confirmed, load the jars onto the rollers. The lid of each jar must face the optical encoder on the left side of the cabinet (see Figure 5).
  • Page 7: Operating Instructions

    Gilson Company, Inc. Micro-Deval Apparatus: MD-2000, MD-2000C & MD-2000F • Close the doors properly to insure the safety interlock NOTE: Excessive tightening of the knob may result is active and press the Green <START> button. The in deformation of components. Tighten only until jars will turn and the controller will count down to zero snug and free from leaks.
  • Page 8: Routine Cleaning

    Gilson Company, Inc. Micro-Deval Apparatus: MD-2000, MD-2000C & MD-2000F 8.1 Routine Cleaning: 2. Repeat for the dust shield panels on the left side. The optical path from the encoder to the sensor decal on 3. Open master link by spreading the legs apart and the jar lid should be periodically inspected for excessive pushing the retaining clip off.
  • Page 9: 10.0 Parts Diagram

    Gilson Company, Inc. Micro-Deval Apparatus: MD-2000, MD-2000C & MD-2000F 10.0 PARTS DIAGRAM: Top Cover Left Top-Dustshield Panel Left Mid-Dustshield Panel Bottom Door Figure 5 Page 9...