Download Print this page

Troubleshooting - Kampa Breeze PU0161 User Manual

12v two-stage high pressure pump

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
IMPORTANT!
Due to their valve design, Kampa
the deflation function of the pump. However, Kampa
maintain high pressures and so, when the valves are opened, a large volume of
air is released very quickly. Normally, only a relatively small volume of air remains
within the AIR frame tubes which is easily expelled when packing away.
Recycling Advice
Waste electrical products should not be disposed of with household
waste. Please recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice.

Troubleshooting

Problem
The pump has
no power/LCD
Display does not
illuminate.
LCD Display
shows pressure
value >0
The pressure
increases quickly.
The pump
keeps switching
between its low
and high pressure
pump operation.
PU0161-UM-11-15 Rev.A
awnings and tents CANNOT be deflated using
®
Possible Reason
The pump is not
receiving any power.
A temperature
difference has
caused the sensor to
malfunction.
There may be an
obstruction in the
airflow.
There may be a fold
or kink in one of the
air poles.
The pump has
been operating
continuously for too
long, the sensor is
reading too high a
temperature.
The sensor is not
relaying the current
pressure and/or
another malfunction
has occurred with
the sensor.
AIR frames are designed to
®
Solution
Check that the DC plug is fully inserted
into the socket. Check that the socket
is functioning correctly by plugging into
another DC 12V device.
Press and hold the Confirmation/Power
Button (F) for 6 seconds which should
reset the sensor.
Turn the power off immediately and
check/clear the nozzle or inflation point/
valve for any obstructions.
Flatten out the inflatable to ensure nothing
is trapped so that the air can flow
through with minimal restriction.
Turn off the power and allow the pump
to cool down. Resume operation after
30 minutes.
Turn off the power. Remove the air hose
from the inflatable product. Restart the
pump and press the Confirmation/
Power Button (F) for 6 seconds. The
display should indicate zero. Re-input the
required pressure. Reconnect the hose to
the item to be inflated and resume.
6

Advertisement

loading