Technical Specifications; Operational Instructions - Gerni Multi 22 User Manual

Table of Contents

Advertisement

Technical specifi cations
Model
Container material
Voltage (V)
P
(W)
NOM
P
(W)
max
Max Vacuum, kPa/bar
Max Suction power -
machine, W
Sound power
(EN 60704-2-1), dB(A)
Tank size, L
Net fi lling dry, in bag, L
Net fi lling liquid, L
Filter indicator
Push to Clean
Power out, max 1100
W
Auto on/off
Variable suction
control

Operational instructions

Using the vacuum cleaner
On/Off - position "E"
Switch "0-I"
Switch position
I
I
0
0
Powertool Auto On/Off - position "A"
Switch "0-I"
Switch position
I
I
0
0
The machine provides two modes of operation:
vacuuming and blowing.
When using the machine for vacuuming, the hose is
connected to "G". When using the machine for blow-
ing, the hose is connected to "H".
The machine is turned on or off at switch "E".
When running and operational the light in "B" will not
light. The light "B" will light when a drop in suction
performance occurs due to a dirty fi lter.
Original Instructions
Multi 22
Multi 22 T Inox
PP
INOX
220 - 240
220 - 240
1130
1130
1200
1200
20/200
20/200
270
270
85
22
9
14
yes
yes
yes
yes
Function
On
Off
Function
On
Off
Multi 30 T Inox
INOX
220 - 240
1260
1400
21/210
292
85
87
22
30
9
13
14
20
yes
yes
yes
yes
yes
Cleaning the fi lter with Push to Clean*)
If the light "B" is turned on, the fi lter may be clogged.
1. Hold one hand against the end of the hose to form
a closed wall. Push the "Push to Clean" button "C"
for 2-3 seconds to let the machine clean the fi lter.
Wait for 3-5 seconds and repeat Step 1, max. 3
times.
2. If the indicator still lights, the cause may lie in a
too heavily clogged fi lter. Occasionally a light rinse
is suffi cient. If not, then replace the fi lter by a new
one.
Filter change (ref. illu. 4, page 2)
1. Open the machine so the fi lter is accessible.
2. Unscrew the tensioning plate "M" to release the
fi lter.
3. Remove the fi lter and replace it by a new one.
4. Tighten tensioning plate (turn right). Make sure
the threads on the tensioning plate are aligned
properly with the threads on the machine. Tighten
the tensioning plate fi rmly so the fi lter seals make
a closed connection to the machine. Beware not
to over-tighten the tensioning plate.
5. Assemble the machine again making sure the mo-
tor head has a proper fi t to the container.
Dust bag change
1. Open the machine so the dust bag is accessible.
2. Remove the old dust bag.
3. Gently slide the new dust bag over the angled
Multi II
Multi 50 Inox
INOX
220 - 240
1260
1400
21/210
292
87
50
20
36
yes
yes
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents