Preparing The Indoor Side Tubing - Sanyo CH2442 Installation Instructions Manual

Split system heat pump air conditioner
Hide thumbs Also See for CH2442:
Table of Contents

Advertisement

3-14. Preparing the Indoor Side Tubing

KH2442
Tubing can be extended in 4 directions as shown in
Fig. 3-35.
Arrangement for Left Tubing
2 2 2 2 2
(a) Cut out the left tubing outlet. (Fig. 3-36)
Arrangement for Right Tubing
K
(a) Cut out the right tubing outlet using a hacksaw.
(Fig. 3-37)
Arrangement for Left-rear and Right-rear Tubing.
(a) It is not necessary to cut a hole.
KH3642
Tubing can be extended in 4 directions as shown in
Fig. 3-35.
Arrangement for Right-rear Tubing
(a) Remove the 2 screws and slide out the side
cover. (Fig. 3-38)
(b) Extend the wide tube from the outdoor side and
connect it directly to the mating tube inside the
indoor unit. Use a flare nut. (Fig. 3-39)
Arrangement for Right Tubing
(a) Remove the 2 screws and take off the side cover.
(Fig. 3-38)
(b) Cut out the L-shaped tubing outlet using a hacksaw.
(Fig. 3-40)
(c)
Using the L-shaped tube (field supply), connect
tubing between the indoor and outdoor units.
(Fig. 3-42)
Arrangement for Left and Left-rear Tubing.
(a) Remove the 4 screws (2 on each side) and take
off both left and right side cover. (Fig. 3-41)
(b) Remove 4 screws to remove the bottom cover.
(c)
Using the L-shaped tube (field supply), connect
tubing as in Fig. 3-43.
Indoor unit
Left
side
Bottom
cover
cover
Fig. 3-41
Left
tubing
Left tubing
outlet
Right
side
cover
L-shaped tube
1361_T_I
Fig. 3-42
26
S4359146
Left-rear
tubing
Fig. 3-35
Fig. 3-36
0950_T_I
Fig. 3-38
Fig. 3-39
Fig. 3-40
1360_T_I
Fig. 3-43
Right-rear
tubing
(Recommended)
Right tubing
0949_T_I
Right tubing
outlet
0951_T_I
Fig. 3-37
1356_T_I
Tubing
from the
outdoor
unit
1357_T_I
Hack
saw
1358_T_I
L-shaped
tube
1359_T_I