  • Page 1 SES 302 and SES 303 Temperature & Humidity Sensor User and Installation Instructions BGX501-923-03...
  • Page 2 SES 302 and SES 303 The Secure SES 302 and SES 303 form part of a Z-Wave Plus™ home automation network. The SES 302 measures temperature whilst the SES 303 measures temperature and humidity. The sensors are battery-operated devices which transmit information to an associated device in a network.
  • Page 3: External Pipe And Tank Temperature Sensors (Optional)

    External Pipe and Tank Temperature Sensors (Optional) The SES 302/303 can support either 1-thermistor (SES 001) or up to 4-external digital temperature sensors (SES 002/003). Please take note of the following: Refer “Product Ordering Codes” section for order details. The connector for external probes is on the rear wall plate.
  • Page 4 Wall Plate 1 2 3 4 5 Connector for External Sensors Refer to the Pipe/ Tank temperature sensor (SES 00x) manual for the connection diagram.
  • Page 5 Installation Keep the SES 302 / SES 303 in its sealed pack until all dust and debris have been cleared away prior to making connections. Remove the wall plate from the rear of the SES 302/303. The wall plate can be released by...
  • Page 6 Wallplate a) Push spring clips to release b) Swing wallplate out and down...
  • Page 7 Choose the position where the unit is to be mounted (refer to the following layout). 1.5 m Avoid locations alongside or behind large metal surfaces that could interfere with the low power radio signals between the unit...
  • Page 8 and the controller. The sensor should be mounted on an internal wall, approximately 1.5 metres (5 feet) above floor level and away from draughts, direct heat sources and sunlight. Make sure that there is sufficient space around the unit to allow easy access to the two retaining spring clips on the base of the wall plate.
  • Page 9: Including And Excluding A Device

    Fit 2 x AA 1.5V batteries Check correct polarity Fit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 302/303 will now power up.
  • Page 10 Include if you are adding a device to the network or select Exclude if you are removing a device from the network. Check with the controller manufacturer’s manual. Button Step 2: On the SES 302 or SES 303, press the button, hold and release after 1 second...
  • Page 11 If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 302/SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network.
  • Page 12 Please note that some controllers can automatically associate. Always check with the manufacturer’s manual. Step 1: Put the controller into Association Mode. Step 2: Press and hold SES 302/ SES 303 button for more than 1 second and then release.
  • Page 13 SES 302/SES 303 will send temperature report of onboard sensor. Note: this feature only works when the device has been included in network and the nodes associated. Sending Node Information- Press and hold SES 302/303 button for more than 1 second and then release.
  • Page 14 Device Endpoints details End Point Reports to the nodes at the Endpoint Measured Temperature report. Measured Humidity report. Low battery Alarm report. Temperature report external digital sensor 01 or thermistor. Temperature report external digital sensor Temperature report external digital sensor Temperature report external digital sensor...
  • Page 15: Technical Information Of Z-Wave Plus Command Classes

    Technical Information of Z-Wave Plus command classes Z-Wave Plus Device Implemented Device Class Classes Generic Multilevel sensor Specific Routing Multilevel sensor Basic Routing Slave Battery operated devices do not support routing functionality. Command Class Commands Supported Multilevel Sensor (V6) Report Used to report measured sensor values to associated nodes.
  • Page 16 Manufacturer ID = 0x0059 Product Type ID = 0x000D Product ID = 0x0002 (SES 302) Product ID = 0x0003 (SES 303) Version (V2) Report Version Command Class Get Version Command Class Report Battery Level (V1) Report Battery report is issued on a battery change or when a low-level battery is detected.
  • Page 17 Wake Up No More Information Wakeup interval step is 60 seconds Minimum wakeup interval is 2 minutes Maximum wakeup interval is 24 hours Default wakeup interval is 24 hours Association (V2) Report Remove Supported Groupings Get Supported Groupings Report Specific Group Get Command Specific Group Report Command Product supports one group for each end point that have...
  • Page 18 Multi Channel Capability Report Multi Channel End Point Find Multi Channel End Point Find Multi Channel Command Encapsulation...
  • Page 19 Up to a maximum of five end points supported. The number of end points on the product is detected based on the number of external sensors connected to the product at the time of Inclusion. If external sensor not connected this command class is not supported.
  • Page 20 Configuration (V1) Report For configuration details refer to the “Configuration Parameters” section. Device Locally Reset (V1) Report Button press 3 times within 3 seconds will put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network.
  • Page 21 Profile MSB - ASSOCIATION_GROUP_INFO_REPORT_PROFILE_G ENERAL Profile LSB - ASSOCIATION_GROUP_INFO_REPORT_PROFILE_G ENERAL_NA Supported Command class and command : COMMAND_CLASS_SENSOR_MULTILEVEL, SENSOR_MULTILEVEL_REPORT_V6 COMMAND_CLASS_BATTERY, BATTERY_REPORT Z-Wave Plus Info (V2) Report...
  • Page 22 Role Type - ROLE_TYPE_SLAVE_SLEEPING_REPORTING Node Type - ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEP LUS_NODE Installer Icon- ICON_TYPE_SPECIFIC_SENSOR_MULTILEVEL_MUL TIDEVICE User Icon- ICON_TYPE_SPECIFIC_SENSOR_MULTILEVEL_MUL TIDEVICE Power Level Set Power Level Get Power Level Report Power Level (V1) Power Level Test Node Set Power Level Test Node Get Power Level Test Node Report None...
  • Page 23: Configuration Parameters

    Configuration Parameters Delta °C 0°C 1 - 5 Temp Temp Reporting Mins 5 Min 1 – 5 Interval Delta Humidity Humidity Reporting Mins 5 Min Interval...
  • Page 24 Common attributes: Access Types = Read/ Write Size Bytes = 1, Min Value = 0, Max Value = 255 Zero configuration mean that the corresponding functionality is disabled. Configuration value = Desired value/ Resolution. Example: To configure Delta temperature to 2 °C. The value need to be configured in device is 2/0.1 = 20.
  • Page 25: Product Ordering Codes

    Product Ordering Codes Z-Wave NU2010302000 Temperature Sensor Z-Wave NU2010303000 Temperature and Humidity Sensor Thermistor Temperature BGX301-536 Sensor with 3m cable Digital Pipe & Tank NU5680501000 Temperature Sensor with 1m cable Digital Pipe & Tank NU5680601000 Temperature Sensor with 4m cable...
  • Page 26: Technical Specifications

    Technical Specifications Specification applies to both SES 302 and SES 303 unless otherwise stated. Electrical Purpose of Control: Electronic Temperature and Humidity Sensor (Independently Mounted) Software Class: Class A Battery operated device using two AA batteries. ** Do not use rechargeable batteries** Each battery: 1.5V...
  • Page 27 For 5-years battery life, delta reporting should be zero and no external sensors: SES 302: configure >15min reporting interval SES 303: configure >1hour reporting interval Measurement SES 302: Temperature Accuracy: ±0.5°C for 0°C to 40°C SES 303: Temperature Accuracy: ±0.5°C for 0°C to 40°C...
  • Page 28 Mechanical Dimensions: 85x85x30 mm Case Material: Thermoplastic, flame retardant Mounting Wall mounting to fit a single gang wall box Weight (single unit 205 ± 30 g packing): Ball Pressure Test 75°C Temperature: After Care: Clean only with a clean damp cloth; do not use any aggressive cleaning agents.
  • Page 29 Environmental Storage temperature: -20°C to 55°C Operating temperature: 0°C to 40°C Environmental humidity range: 0%RH to 95%RH Atmospheric Range: 980 to 1035 hPa Pollution Degree: Degree 2 Enclosure protection: IP30 Radio Receiver Category: Category 3 Power Class: Class B RF frequency Europe &...
  • Page 30 This is a Z-Wave certified product and can be used with Z-Wave controllers that support its functionality. Please refer to the documentation provided by the gateway or controller manufacturer. See the Z-Wave alliance website www.z-wavealliance.org for certified controllers. Compliance IEC 61010-1 R&TTE directive ETSI EN 300 220-2 EN 301 489 part 1 &...
  • Page 31 NOTES...
  • Page 34 European Head Office Secure Controls (UK) Ltd. South Bristol Business Park Roman Farm Road Bristol, BS4 1UP, UK e: info@securetogether.com www.securetogether.com European Sales Office CEWE Instrument AB Box 1006, 611 31 Nyköping t: +46 8 600 80 60 e: info@securetogether.com...
  • Page 35 Australia Sales Office Secure Australasia Pty Ltd 258 Darebin Road Fairfield VIC 3078 Australia p: +61 3 9485 6000 f: +61 3 9485 6099 e: info@securetogether.com www.securetogether.com Secure Meters Ltd Pratapnagar Industrial Area Udaipur 313003 India p: +91 294 2492 300-05 f: +91 294 2492 310 e: mktg@securetogether.com...
  • Page 36 Elegant Metering Solutions FZE 4EA 326, P.O. Box 54857 Dubai Airport Free Zone Dubai, UAE p: +971 50 6575166 f: +971 04 204 5619 e: emsfze@emsdxb.ae www.securetogether.com...

This manual is also suitable for: