Operating
I nstructions
–
A ssisi
L oop-‐150
Thank
y ou
f or
c hoosing
A ssisi,
a
n on-‐invasive,
n on-‐drug
therapy
f or
y our
p et.
T he
A ssisi
L oop
1 50
o ffers
1 50
1 5-‐
minute
t reatments
a nd
i s
f or
u se
o nly
o n
y our
p et
a s
instructed
b y
y our
v eterinarian.
1. Place
t he
c enter
o f
t he
l oop
o ver
t he
a rea
t hat
needs
t reatment.
Pulsed
e lectromagnetic
therapies
m ay
h ave
effects
o n
t he
f unctioning
of
p owered,
m etallic
cardiovascular
i mplants
o r
neuronal
i mplants.
M ake
sure
t hat
d istance
i s
maintained
f rom
i ndividuals
w ith
t hese
t ypes
o f
implants
w hile
A ssisi
L oop
i s
d elivering
t reatment.
2. Press
t he
o n/off
b utton
o nce.
T reat
f or
1 5
minutes.
3. After
1 5
m inutes
t he
d evice
w ill
a utomatically
turn
i tself
o ff.
4. If
y ou
w ant
t o
t reat
f or
l ess
t han
1 5
m inutes,
simply
p ress
t he
o n/off
b utton
t o
t urn
t he
d evice
off.
5. For
o ptimal
b attery
l ife,
w ait
a t
l east
2
h ours
between
t reatments
u nless
i nstructed
b y
y our
veterinarian.
I f
y our
v eterinarian
p rescribes
more
f requent
u se,
b attery
l ife
c ould
b e
r educed
substantially.
Applicator
E tiquette
Bending
o r
e longating
t he
a pplicator
t oo
m uch
w ill
hinder
e ffectiveness.
K eeping
t he
a pplicator
a s
c ircular
as
p ossible
p rovides
t he
b est
f ield
o f
t reatment.
Please
v isit
w ww.assisianimalhealth.com
f or
f urther
i nformation.
Please
v isit
w
ww.assisianimalhealth.com
f or
f urther
i nformation.
Assisi
A nimal
H ealth
Toll
F ree:
( 866)
8 30-‐7342
O ffice:
( 415)
8 14-‐2460
F ax:
( 415)
4 81-‐0995
Assisi
A nimal
H ealth
Toll
F ree:
( 866)
8 30-‐7342
O ffice:
( 415)
8 14-‐2460
F ax:
( 415)
4
Safety
W arnings
There
a re
n o
u ser
s erviceable
p arts
i nside
t he
A ssisi
•
Loop.
Not
p rotected
f or
i ngress
t o
w ater.
D o
n ot
g et
t he
•
Assisi
L oop
w et.
Equipment
N OT
S UITABLE
F OR
U SE
I N
T HE
•
PRESENCE
O F
F LAMMABLE
A NESTEHETIC
M IXTURE
WITH
A IR
o r
W ITH
O XYGEN
o r
N ITROUS
O XIDE
o r
OXYGEN
E NRICHED
A TMOSPHERES.
Ensure
t hat
c ase
a nd
a pplicator
l oop
a re
i n
g ood
•
condition.
Pulsed
e lectromagnetic
t herapy
S HOULD
N OT
B E
•
USED
o n
p atients
w ho
h ave
A NY
i mplanted
s ystem
that
m ay
c ontain
l ead.
Assisi
L oop
c an
i nterfere
w ith
a ppliances
t hat
a re
•
designed
t o
d etect
a nd
a mplify
w eak
r adio
s ignals.
This
i ncludes
t elevisions,
r adios,
c itizen
b and
r adios,
potentially
p hones
a nd
o ther
c onsumer
d evices
i n
these
c ategories.
T he
i nterference
m ay
b e
h eard
a s
a
r epetitive
t ick
i n
a n
F M
r adio
a nd
m ay
c ause
tearing
o f
a
T V
p icture.
T hese
c onsumer
d evices
a re
not
g enerally
w ell-‐shielded
a nd
a re
b oth
p roducers
of
a nd
s ubject
t o
E MI
f rom
a ll
s ources.
See
p rotocol
r ecommendations
o n
page
2
o f
t his
d ocument.
81-‐0995
T2-MAN013
R5
T2-MAN013 R5
Need help?
Do you have a question about the Assisi Loop 150 and is the answer not in the manual?
Questions and answers