IMPORTANT SAFETYGUARDS
When using electrical products, especially when children are present,
basic safety precautions should always be followed.
READ ALL INSTRUCTIONS BEFORE USING
In the case 120V 60Hz : Power supply must be a 15 Amp GFCI outlet.
The electrical cord must be connected to a GFCI outlet.
The GFCL outlet should be 1ft. above the floor.
Install only in well-ventilated areas to avoid excess humidity.
Do not install in narrow toilet stalls or in shower stalls.
Install only where direct contact with water is minimized.
Do not install near any heat source.
Avoid using extension cords if possible. Consult with a certified electrician where extension
cords are necessary.
DANGER – To reduce the risk of electrocution:
Do not use while bathing.
Do not place or store product where it can fall or be pulled into a tub or sink.
Do not place in or drop into water or other liquid.
Do not reach for a product that has fallen into water. Unplug immediately.
WARNING – To reduce the risk of burns, electrocution,
fire or injury to persons:
Close supervision is necessary when this product is used by, on, or near children or invalids.
Use this product only for its intended use as described in this manual.
Do not use attachments not recommended by the manufacturer.
Never operate this product if it has a damaged cord or plug, if it is not working properly,
has been dropped or damaged, or dipped into water.
Return the product to a service center for examination and repair.
Keep the cord away from heated surfaces.
Never drop or insert any object into any opening or hose.
Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen
is being administered.
Connect this product to a properly grounded outlet only. See grounding instructions.
Unplug this product before filling. Fill (reservoir) with water only.
BIOBIDET SLIM 1
(120V, 60Hz)
GROUNDING INSTRUCTION
DANGER - Improper use of the grounding plug can result in a risk of electric shock.
This product has a three-prong grounding plug, which must be plugged into an outlet that is properly installed and
grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape
wire for the electric current. If repair or replacement of the cord or plug is necessary do not connect the grounding wire
to either flat blade terminal.
The wire with insulation having an outer surface that is green with or without yellow stripesis the grounding wire.
Check with a qualified electrician or service person if the grounding instructions are not completely understood,
or if in doubt as to whether the product is properly grounded.
This product is for use on a nominal 120V circuit, and has a grounding plug that looks like the plug illustrated in sketch
A in Figure 1.
A temporary adapter, which looks like the adapter illustrated in sketches Band C, may be used to connect this plug
to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet (sketch A) can be installed by a
qualified electrician.
The green colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground
such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by the screw.
Optional Grounding Instructions

Safety Instructions

GROUNDING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLIM 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for bioBidet SLIM 1

  • Page 1 BIOBIDET SLIM 1 User’s Guide (120V, 60Hz) ver.1707 Safety Instructions IMPORTANT SAFETYGUARDS GROUNDING INSTRUCTION DANGER - Improper use of the grounding plug can result in a risk of electric shock. When using electrical products, especially when children are present, basic safety precautions should always be followed.
  • Page 2 Thank you for purchasing the unit. This unit should be installed according to this manual. Read this manual carefully and isntall properly. Do not attempt to service this unit yourself. Doing so could void warranty. Parts & Con guration Operation panel Main Body BIDET INTENSIVE...
  • Page 3 Installation & Trial operation Remove the seat from the existing Remove the water feed pipe and Fix the bracket onto the toilet Push the main body toward the toilet body. then install T-valve. first. bracket completely. Release the nuts, and then remove the seat and cover Top fix metal bolt from it.
  • Page 4 How to Use Sit on the toilet seat Posterior,Feminine,Turbo Pulse Child Fuction Be sure to sit on the seat sensor. Selected function can be used as described. When pressing the Pulse button during the When selecting Child function, settings* will be operation of Posterior,Feminine, and Turbo, water Basically if the sensor is not occupied, all functions will adjusted for children.
  • Page 5 How to Use Seat Temperature Control Nozzle Cleaning Night Light Energy Saving Fuction Automatic energy saving mode Seat temperature is adjustable. (4 levels) When selecting Nozzle Cleaning while not seated, Blue LED night light provides enough brightness to (Off - Low - Middle - High) - This mode will be actiavted by pressing the Energy the nozzle cleans itself 3 times.
  • Page 6 Thank you for purchasing the unit. This unit should be installed according to this manual. Read this manual carefully and isntall properly. Do not attempt to service this unit yourself. Doing so could void warranty. Maintenance & Cleaning Settings Screen Filter Cleaning Maintenance during Winter Season Close the water feed valve.
  • Page 7 Troubleshooting Comparison Chart Features SLIM One Please check the following points before requesting the repair service. Wash Problem Check list Bidet Intensive Check if the power plug is not connected. Completely out of order Check the power failure. Child Check if the water supply is suspended. Normal / Powerful Check if water feed valve is locked.
  • Page 8 37 ~ 104 F (recommened 50 ~ 95 F) Usage room temp. tolerance range Dimension Elongated 18.6”(472) x 20.8”(528) x 7.5”(190) Weight Elongated 10.4 lb (15.2) Net weight (Gross weight) 7900 S ILL Route 31 T) 847.458.2334 BBC Innovation Corp. Crystal Lake IL 60014 F) 847.854.1296 www.biobidet.com...

Table of Contents