GENERAL INFORMATION
The FA6150KP-GP is an addressable, fixed-word display,
remote
keypad
designed
PROTECTION control panels. The address is set via the
keypad keys, and may be continuously backlit for
convenience (depending on the control panel being used).
KEYPAD DISPLAY AND LEDS
The keypad has the following display features:
N
Fixed-Word display of System Status
N
3-digit Zone Identifier
N
Backlit Display (optional on some controls)
N
Dedicated Special Function Keys
N
Built-in Piezo Sounder
The following table shows the LEDs and their functions:
LED
Function
Lights when the system is "ARMED" in any
Red
mode
Lights when the system is "READY" to be
Green
armed.
The keypad's Special Function Keys; A, B, C, and D, may be
programmed for panic alarms or other special functions
such as single-button arming or macros. See the control
panel's Installation and Setup Guide for details.
Function keys must be held down for at least 2
seconds to activate an alarm; key pairs activate
immediately.
Special Function Keys/Panic Alarm Key Pairs
A or [1] & [✱]
B or [✱] & [#]
C or [3] & [#]
D (Special Functions only)
Refer to the control panel's Installation and
Setup Guide for Special Function Key options.
INSTALLATION GUIDE
for
use
with
GUARDIAN
WIRING AND INSTALLATION
The keypad can be surface mounted directly to a wall, or to
a single- or double-gang electrical box.
1.
Remove the case back by pushing down two "snaps"
along the keypad's bottom edge and pulling the two
halves apart. See Figure 1 below.
2.
Route wiring from the control panel through the
opening in the case back.
3.
Mount the case back to a wall or electrical box.
4.
Wire directly from the keypad's terminal block to
the terminal block on the control board as follows:
Wiring Table
Keypad
8
G
Data Out
GND
+
+12VDC
9
Y
Data In
See the control panel's Installation Instructions for
more complete details.
5.
Reattach the keypad to its case back.
ARMED
READY
MOUNTING RELEASE SNAPS
Figure 1. FA6150KP with Protective Door Removed
K3590-GP 3/03
FA6150KP-GP
REMOTE KEYPAD
Control Panel
Color
Data In
Green
Aux Pwr
Black
+ Aux Pwr
Red
Data Out
Yellow
1
2
3
OFF
AWAY
STAY
4
5
6
MAX
TEST
BYPASS
8
9
7
INSTANT
CODE
CHIME
0
#
READY