SUBMITTAL SHEET
SYSTEM
24KS62R
KS2462R/C2462R
WALL MOUNTED AIR CONDITIONER
GENERAL DATA (AT 230V)
POWER
V/PH/HZ
Circuit Ampacity, Min. (A)
Fuse size, Max.
(A)
COMPRESSOR
No. used
R.L. Amps - L.R. Amps (A)
Crankcase Heater
OUTDOOR FAN TYPE
Dia. (in.) - No. used
Type Drive - No. speeds
No. Poles - RPM (High)
No. Motors – W
CFM (High)
F.L. Amps. (A)
OUTDOOR COIL - TYPE
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR FAN - TYPE
Dia. & Length (in.) - No. used
No. speeds
No. Poles -RPM (High)
No. Motors - W
CFM (HI/MED/LOW)
F.L. Amps (A)
INDOOR COIL - TYPE
Fin Type - Pipe type
Rows - F.P.I.
Face Area
(sq. ft.)
Tube Size
(mm )
Drain Connection Size (in.)
REFRIGERANT
Lbs. - R22 (O.D. Unit)
Control
Connection
Line Length,
Max (ft.)
Lift difference, Max (ft.)
Line Size - in. O.D. Discharge
Line Size - in. O.D. Suction
DIMENSIONS (in.)
H
Indoor Unit
-Uncrated
13
-Crated
12-25/32 x 48-15/32
Outdoor Unit -Uncrated
36-5/8
-Crated
39-3/4
WEIGHT
INDOOR
Net (lbs.)
40.0
Shipping (lbs.)
44.0
Shipping Volume(cu.ft.)
5.7
INDOOR/OUTDOOR
230/208/1/60
35
35
Scroll
1
12.5 - 61.0
30W
Propeller
18-3/32 - 1
Direct – 2 (AUTO)
6 - 879
1 - 110
1660
0.9
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 – 14.1
8.72
3/8
Cross-flow
4 & 33-3/8 -1
3 & Auto
4 – 1,324
1 - 30
559/---/---
0.38
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 – 19.5
2.30
7
23/32
R410A
6.6
Capillary Tube
Flare
132
50
3/8 (Insulated tube)
3/4 (Insulated tube)
x
W
x
D
x
44-7/8
x 8-31/32
x 15-31/32
x
37
x 13-3/8
x
39-3/8
x 15-3/4
OUTDOOR
150.0
190.0
14.1
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
COOLING
Total Capacity
(BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity
(BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (bels)
FEATURE
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver (Horizontal)
(Vertical)
Power Failure Automatic Restart
Self Diagnosis
OPTION
Refrigerant Line Set
Low Ambient Control
Fresh Air Intake
Central Remote ON-OFF Control
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removable Remo-con Bracket
Wired remote
OPERATING RANGE
Cooling
Intake Temp.
Maximum
95F DB / 71F WB
Minimum
67F DB / 57F WB
CERTIFICATION
AIRCONDITIONING PRODUCTS
SS24KS62R-2
27,000 / 26,000
15,980 / 15,350
11,020 / 10,650
13.0 / 13.0
6.5 / 6.4
10.2 / 10.9
2,240 / 2,200
7.6
Microprocessor
LCD Wireless type
IC Thermostat
Progrum 24h, 1-hour off
Built-in
Manual
Automatic
Built-In
N/A
AP3210BH (30 ft)
AP3215BH
(50 ft)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
RCS-KS2432AWD
Indoor Air
Outdoor Air
Intake Temp.
115F DB
23F DB (0F DB)
24KS62R

Advertisement

loading

Summary of Contents for Sanyo 24KS62R

  • Page 1 SUBMITTAL SHEET SYSTEM INDOOR/OUTDOOR 24KS62R KS2462R/C2462R WALL MOUNTED AIR CONDITIONER GENERAL DATA (AT 230V) POWER V/PH/HZ 230/208/1/60 Circuit Ampacity, Min. (A) Fuse size, Max. COMPRESSOR Scroll No. used R.L. Amps - L.R. Amps (A) 12.5 - 61.0 Crankcase Heater OUTDOOR FAN TYPE Propeller Dia.
  • Page 2 SUBMITTAL SHEET SYSTEM INDOOR/OUTDOOR 24KLS62R KS2462R/CL2462R WALL MOUNTED LOW AMBIENT AIR CONDITIONER GENERAL DATA (AT 230V) POWER V/PH/HZ 230/208/1/60 Circuit Ampacity, Min. (A) Fuse size, Max. COMPRESSOR Scroll No. used R.L. Amps - L.R. Amps (A) 12.5 - 61.0 Crankcase Heater...

This manual is also suitable for:

Ks2462rC2462r24kls62rCl2462r