Gilbarco TRIND MULTI 1 C00012-001-WF-D Installation Manual

Transmitter/receiver in dispenser retrofit kits

Advertisement

Quick Links

Installation
Introduction
Purpose of this Manual
Prerequisites

Important Notice

Required Reading

Related Documents

MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
This manual provides instruction for installing TRIND™ Multi 1 Retrofit Kits in The
Advantage
Series wide frame and narrow frame units with InfoScreen
®
CRIND
, or single-line CRIND.
®
The TRIND option allows customers to automatically authorize CRIND-equipped units using
a hand-held transponder tag provided by a major oil company (MOC). Use this kit for one- or
two-sided units.
Before installing the TRIND kit, ensure that the existing CRIND has the Z-180 logic board
T17764-XX, which is not provided in TRIND retrofit kit.
This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy, and if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense. Changes or modifications not expressly approved by the
manufacturer could void the user's authority to operate this equipment.
Before installing the equipment, the installer must read, understand, and follow:
• this manual
• NFPA 30A, The Automotive and Marine Service Station Code
• NFPA 70, The National Electric Code
• applicable federal, state and local codes and regulations
Failure to do so may adversely effect the safe use and operation of the equipment.
Note: This kit must be installed by a Gilbarco ASC (Authorized Service Contractor) to insure
warranty.
MDE-2531
Pump & Dispenser Start-Up & Service Manual
MDE-2562
CRIND Service Manual
MDE-2628
Cash Acceptor Retrofit Assemblies for The Advantage Series with CRIND
MDE-2620
Graphics Panel Application for The Advantage Series
PT-1728
The Advantage Series Illustrated Parts Manual
PT-1736
CRIND Card Reader Illustrated Parts Manual
TRIND™ MULTI 1
Transmitter/Receiver in Dispenser
Retrofit Kits C00012-001-XX
, monochrome
®
MDE-3801
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRIND MULTI 1 C00012-001-WF-D and is the answer not in the manual?

Questions and answers

Summary of Contents for Gilbarco TRIND MULTI 1 C00012-001-WF-D

  • Page 1: Important Notice

    • applicable federal, state and local codes and regulations Failure to do so may adversely effect the safe use and operation of the equipment. Note: This kit must be installed by a Gilbarco ASC (Authorized Service Contractor) to insure warranty.
  • Page 2: Required Tools

    Introduction Required Tools The following equipment is needed to install all TRIND™ Multi 1 kits • Allen wrench set, American standard • clean cloth or rag • chip extraction tool, e.g., IC extraction, Digikey Part No. K158-ND or equivalent • isopropyl alcohol (part# END-1082) •...
  • Page 3: Parts Lists

    Parts Lists Parts Lists Kits for Wide Frame Units, Dual- and Single-Sided Kits C00012-001-WF-D (dual-sided) and C00012-001-WF-S (single-sided) for The Advantage Wide Frames (48’’) contain the following parts. Description Part Number Quantity WF-D Kit Quantity WF-S Kit cable clamp, gray Q13558-04 cable group Q13781-01...
  • Page 4: Kits For Narrow Frame Units, Dual- And Single-Sided

    Parts Lists Kits for Narrow Frame Units, Dual- and Single-Sided Kits C00012-001-NF-D (dual-sided) and C00012-001-NF-S (single-sided) for The Advantage Narrow Frames (36’’) contain the following parts. Description Part Number Quantity WF-D Kit Quantity NF-S Kit cable clamp, gray Q13558-04 cable group Q13781-01 For components see table “Q13781-01 Cable Group”...
  • Page 5: Safety Information

    Safety Information Safety Information Alert Symbol and Signal Words Alert Symbol: This is a standard ANSI* approved alert symbol. When you see this symbol, be alert to the potential for a personal injury. * Reference American National Standard Bulletins ANSI Z535. Signal Words: These signal words alert you to important safety hazards.
  • Page 6: Before Beginning

    Safety Information Before Beginning Do the following: WARNING Dangerous Environment! Failure to install this equipment in accordance with NFPA 30A and NFPA 70 could result in severe injury or death. Read, understand and follow NFPA 30A and NFPA 70. Read all instructions before beginning. Follow all safety precautions, including: •...
  • Page 7 Safety Information Use Electrostatic Discharge Precautions Place yourself at a neutral static-free potential by doing the following: 1 Touch an unpainted metal surface. 2 Use a wrist strap connected to a grounded metal frame or chassis. Note: Failure to use electrostatic discharge precautions may damage electronic components and void warranty.
  • Page 8: Preparing For Installation

    Installation Installation Preparing for Installation 1 Before proceeding read and follow all safety instructions and procedures. 2 Open main access doors. Refer to MDE-2531, Pump and Dispenser Start-Up/Service Manual for access instructions. 3 Disconnect and remove existing hardware according to the following: •...
  • Page 9: Modifying Right Options Door On Wide Frame Units

    Installation Modifying Right Options Door On Wide Frame Units For all narrow frame units, or wide frame units without stop or call buttons or door alarm switches, proceed to “Installing Cables” on page 13. For wide or narrow frame units without stop or call units but with door alarm, proceed to “Re-installing Door Alarm Switches”...
  • Page 10 Installation 2 Use center punch and hammer to mark placement of pump stop or call button hole on new right options door by measuring from door edges as shown below. S0001734 " " 3 Away from fuel island, drill a 7/8 inch diameter hole in location illustrated above. 4 Remove any burrs around hole with deburring tool or rounded file.
  • Page 11: Re-Installing Button

    Installation Re-installing Button 1 Hold contact base on back of door and align with hole drilled earlier. Push button S0001735 Base Contact switch Contact base assembly block 2 Insert push button from front of door by aligning tabs with slots in base. 3 Turn push button 45°...
  • Page 12: Re-Installing Door Alarm Switches

    Installation Re-installing Door Alarm Switches For units with cash acceptors, follow these steps to re-install door alarm assemblies on TRIND™ right option doors. Refer to diagram on this page for more information. Perform each step for both ‘A’ and ‘B’ side right option doors. 1 Remove lock hardware from new right options door.
  • Page 13: Installing Cables

    Installation Installing Cables Position kit cables according to the following steps: 1 Carefully pry out printer cable retainer from underside of printer shelf. 2 Disconnect printer cable and pull cable out of 2 3/4" round hole from bottom, and install piece of strip grommet Q10315-06/B around perimeter of hole.
  • Page 14: Installing Card Cage

    Installation Installing Card Cage Prepare T20538-G1 card cage for installation. Note: For more cable connection detail see “Cable Block Diagrams” on page 24. 1 Locate tab at left front top of card cage. 2 From B side of unit, turning card cage sideways to unit, feed top and rear of card cage up and into shelf.
  • Page 15 Installation Address Gateway Board Before Installing Card Cage Address for TRIND™ must match address on CRIND logic board. Follow these steps: ® 1 From A side of unit lower CRIND tray. Refer to MDE-2562 CRIND Service Manual. 2 Locate jump jacks on A and B side CRIND logic boards T17764-XX. 3 Note position of jump jacks and set jump jacks on Gateway board T20128 to match address on CRIND logic boards for both A and B sides.
  • Page 16 Installation Install card cage assembly. Install card cage by doing the following: Tab on card cage clinch nut card cage front facing B side Note: While it is not necessary to remove printer to install card cage you may find your initial installations easier if this is done.
  • Page 17: Installing Right Option Door

    Installation Installing Right Option Door Mount New Right Options Door Install new right options door according to the following steps. 1 If sheet metal shield has not been previously removed, using 1/4’’ nut driver, remove sheet metal shield from back of door. Refer to illustration in “Modifying Right Options Door On Wide Frame Units”...
  • Page 18: Connecting Remaining Cables

    Installation Connecting Remaining Cables 1 From A side, pass J250 end of cable R20437-G01, J176 and JA ends of cable R20665-G1 and J177 and PA ends of cable R20665-G2 through card cage to B side. P186 P250 on Gateway Board pass cables through cage P176...
  • Page 19: Crind ® Bios Trind™ Multi 1 Upgrade

    CRIND® BIOS TRIND™ Multi 1 Upgrade CRIND BIOS TRIND™ Multi 1 Upgrade ® Units must have current Z-180 CRIND logic board. Install the CRIND Bios TRIND software K93744-01, one per logic board, on the T17764-XX CRIND logic board(s) according to the following steps. Note: A properly grounded electrostatic discharge wrist strap must be worn during this procedure.
  • Page 20 CRIND® BIOS TRIND™ Multi 1 Upgrade 1 Locate and remove existing BIOS at U7 on CRIND logic board T17764-XX using a ® grounded chip removal tool. Grounding strap Chip removal tool 2 Install TRIND BIOS K93744-01 (one per logic board) at position U7, orienting notch on chip with indication mark on board as shown.
  • Page 21: Dispenser Set-Up

    Dispenser Set-Up Dispenser Set-Up Addressing Dispenser Each dispenser on the G-Site controller must be addressed differently; no two dispensers may have the same address. Address is at discretion of the installer. Follow these steps: 1 From A side of unit, locate dip switches on power supply board (PCB) T20314-G1 in card cage.
  • Page 22 Dispenser Set-Up Testing TRIND™ Multi 1 1 If printer was removed, replace printer and reconnect two cables and ground. 2 Restore power to unit. Refer to Pump and Dispenser Service Manual MDE-2531. 3 Restoring power with new Bios will Cold Start the CRIND. Refer to CRIND Service Manual MDE-2562.
  • Page 23: Completing Installation

    Dispenser Set-Up Completing Installation 1 Close and secure option and maindoor. 2 Install graphics. Refer to MDE-2620 Graphics Installation for The Advantage Series. 3 Peel backing paper off FCC label pate provided in kit. 4 Affix FCC label plate to inside frame sheathing on column under existing FCC label. 5 Restore power to unit.
  • Page 24: Cable Block Diagrams

    Cable Block Diagrams Cable Block Diagrams Page 24 MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99...
  • Page 25 NARROW FRAME DOOR ONLY GILBARCO CONFIDENTIAL FINAL PROTECTIVE FINISH GILBARCO INC. UNPUBLISHED THIS PRINT IS THE PROPERTY OF GREENSBORO, N.C. GILBARCO INC., N.C., U.S.A. DIAGRAM, TRIND INFORMATION HEREON IS CONFIDENTIAL AND MUST NOT BE REPRODUCED OR RELEASED OUTSIDE GILBARCO WITHOUT MULTI_1, BLOCK PROPER AUTHORIZATION.
  • Page 26 Cable Block Diagrams © 1999 Gilbarco, Inc. • 7300 West Friendly Avenue • Post Office Box 22087 • Greensboro, North Carolina 27420 • Phone (336) 547-5000 • http://www.gilbarco.com MDE- 3801 10/99 Printed in the U.S.A.