Models :
MELSEC FX
series manufactured
2N
from July 1st, 1997
FX
-
ER-ES/UL FX
-
ET-ESS/UL
2N
2N
Where
indicates:32,48
FX
-16EX-ES/UL
FX
-16EYR-ES/UL
2N
2N
FX
-16EYT-ESS/UL
2N
from April 1st, 1998
FX
-48ER-DS
FX
-48ET-DSS
2N
2N
from August 1st, 1998
FX
-48ER-UA1/UL
2N
from August 1st, 2005
FX
-8ER-ES/UL
FX
-8EX-ES/UL
2N
2N
FX
-8EYR-ES/UL FX
-8EYT-ESS/UL
2N
2N
For the products above, PLCs manufactured
before March 31st, 2002 are compliant with EN50081-2 (EN61000-
6-4) and EN50082-2
from April 1st, 2002 to April 30th, 2006 are compliant with EN50081-
2 (EN61000-6-4) and EN61131-2:1994+A11:1996+A12:2000
after May 1st, 2006 are compliant with EN61131-2:2003
Standard
Remark
EN61000-6-4:2007
Compliance with all relevant aspects
- Generic emission
of the standard.
standard
• Radiated Emissions
Industrial environment
• Mains Terminal Voltage Emissions
EN50081-2:1993
Electromagnetic
compatibility
EN50082-2:1995
Compliance with all relevant aspects
Electromagnetic
of the standard.
• RF immunity
compatibility
• Fast Transients
- Generic immunity
standard
• ESD
• Conducted
Industrial environment
• Power magnetic fields
EN61131-2:1994
Compliance with all relevant aspects
/A11:1996
of the standard.
• RF Immunity
/A12:2000
Programmable controllers
• Fast Transients
• ESD
- Equipment
• Damped oscillatory wave
requirements and tests
EN61131-2:2003
Compliance with all relevant aspects
Programmable controllers
of the standard.
- Equipment
EMI
requirements and tests
• Radiated Emissions
• Conducted Emissions
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Requirement for Compliance with LVD directive
The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Low Voltage (2006/95/EC) when used as directed by
the appropriate documentation.
Type :
Programmable Controller (Open Type Equipment)
Models :
MELSEC FX
series manufactured
3G
from November 1st, 2008 FX
-
MT/ES(-A)
3G
Where
indicates:14,24,40,60
from December 1st, 2008 FX
-
MR/ES(-A)
3G
Where
indicates:14,24,40,60
from March 1st, 2009
FX
-
MT/ESS
3G
Where
indicates:14,24,40,60
from December 1st, 2009 FX
-
MR/DS
3G
Where
indicates:14,24,40,60
Standard
Remark
EN61131-2:2003
The equipment has been assessed
Programmable controllers
as a component for fitting in a
- Equipment
suitable enclosure which meets the
requirements and tests
requirements of EN61131-2:2003
Models :MELSEC FX
series manufactured
2N
from July 1st, 1997
FX
-
ER-ES/UL FX
-
ET-ESS/UL
2N
2N
Where
indicates:32,48
FX
-16EYR-ES/UL
2N
from April 1st, 1998
FX
2N
-48ER-DS
from August 1st, 1998 FX
-48ER-UA1/UL
2N
from August 1st, 2005 FX
-8ER-ES/UL
FX
-8EYR-ES/UL
2N
2N
For the products above, PLCs manufactured
before March 31st, 2002 are compliant with IEC1010-1
from April 1st, 2002 to April 30th, 2006 are compliant with EN61131-
2:1994+A11:1996+A12:2000
after May 1st, 2006 are compliant with EN61131-2:2003
Standard
Remark
IEC1010-1:1990
The equipment has been assessed
/A1:1992
as a component for fitting in a
Safety requirements for
suitable enclosure which meets the
electrical equipment for
requirements of IEC 1010-1:
measurement, control, and
1990+A1:1992
laboratory use
- General requirements
EN61131-2:1994
The equipment has been assessed
/A11:1996
as a component for fitting in a
/A12:2000
suitable enclosure which meets the
Programmable controllers
requirements of EN61131-2:
- Equipment
1994+A11:1996+A12:2000
requirements and tests
EN61131-2:2003
The equipment has been assessed
Programmable controllers
as a component for fitting in a
- Equipment
suitable enclosure which meets the
requirements and tests
requirements of EN61131-2:2003
Caution for compliance with EC Directive
Installation in Enclosure
Programmable logic controllers are open-type devices that must be
installed and used within conductive control boxes. Please use the
FX
Series programmable logic controllers while installed in
3G
conductive shielded control boxes. Please secure the control box lid
to the control box (for conduction). Installation within a control box
greatly affects the safety of the system and aids in shielding noise
from the programmable logic controller.
Associated manuals
FX
Series PLC (main unit) comes with this document (hardware
3G
manual).
For a detailed explanation of the FX
Series hardware and
3G
information on instructions for PLC programming and special
extension unit/block, refer to the relevant documents.
Manual name
Manual No.
Description
FX
Series
Explains FX
Series PLC
3G
3G
JY997D31301
User's Manual
specification details for I/O,
MODEL CODE:
- Hardware
wiring, installation, and
09R521
Edition
maintenance.
FX
/FX
/
3G
3U
Describes PLC
FX
Series
3UC
JY997D16601
programming for basic/
Programming
MODEL CODE:
applied instructions STL/
Manual
09R517
SFC programming and
- Basic & Applied
devices.
Instruction Edition
Explains N:N link, parallel
FX Series User's
JY997D16901
link, computer link, no
Manual - Data
MODEL CODE:
protocol communication by
Communication
09R715
RS instructions/FX
Edition
232IF.
FX
3G
/FX
3U
/
Describes specifications for
FX
Series
JY997D16701
analog control and
3UC
User's Manual
MODEL CODE:
programming methods for
- Analog Control
09R619
FX
/FX
/FX
3G
3U
3UC
Edition
PLC.
FX
/FX
/
Explains the specifications
3G
3U
FX
Series
JY997D16801
for positioning control of
3UC
User's Manual
MODEL CODE:
FX
3G
/FX
3U
/FX
3UC
- Positioning
09R620
and programming
Control Edition
procedures
How to obtain manuals
For the necessary product manuals or documents, consult with the
Mitsubishi Electric dealer from where you purchase your product.
Incorporated Items
Check if the following product and items are included in the package:
Included Items
Main units
Product
Dust proof protection sheet
FX
-14M ~
3G
FX
-60M
3G
Manuals [Japanese version
English version]
Input/output extension units
Product
FX
-32E ,
2N
Extension cable
FX
-48E
2N
Input/output number label
Input/output extension blocks
Product
FX
-8E
2N
FX
-16E
2N
Input/output number label
*1 The FX
-
M /ES-A becomes Chinese version.
3G
1.
Outline
For the input/output extension units/blocks, refer to the following
manual.
-
2N
→ Refer to FX
3G
Series User's Manual - Hardware Edition.
1.1
Part names
[3]
[4]
Series
[2]
[1]
Series
[10]
[11]
No.
Name
[1]
Peripheral device connecting connector cover
[2]
Terminal names
[3]
Top cover(S) (40points, 60points type only)
[4]
Top cover
[5]
Terminal block covers
[6]
Input display LEDs (red)
[7]
Extension device connecting connector cover
1 unit
1 sheet
*1
1 manual
,
each
1 unit
1 cable
1 sheet
1 unit
1 sheet
[5]
[6]
[7]
[8]
[9]

Advertisement

loading

This manual is also suitable for:

Fx3u-4ad-adpFx3u-485adpFx3u-4da-adpX3u-4ad-pt-adpFx3u-4ad-tc-adpFx3u-485adp-mb ... Show all