JY997D33401F(ENGLISH)
FX
SERIES PROGRAMMABLE
3G
CONTROLLERS
HARDWARE MANUAL
Manual Number
JY997D33401
Revision
F
Date
December 2009
This manual describes the part names, dimensions, mounting,
cabling and specifications for the product. This manual is extracted
from FX
Series User's Manual - Hardware Edition. Refer to FX
3G
3G
Series User's Manual - Hardware Edition for more details. Before
use, read this manual and manuals of relevant products fully to
acquire proficiency in the handling and operating the product. Make
sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and
read it whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each
company.
Effective December 2009
Specifications are subject to change without notice.
© 2008 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
may also cause severe injury.
It is important to follow all precautions for personal safety.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals externally cut off all
phases of the power supply.
Failure to do so may cause electric shock.
.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Use the battery for memory backup correctly in FX
Series
3G
User's Manual - Hardware Edition.
- Use the battery only for the specified purpose.
- Connect the battery correctly.
- Do not charge, disassemble, heat, put in fire, short-circuit,
connect reversely, weld, swallow or burn the battery, or apply
excessive forces (vibration, impact, drop, etc.) to the battery.
- Do not store or use the battery at high temperatures or
expose to direct sunlight.
- Do not expose to water, bring near fire or touch liquid
leakage or other contents directly.
- Incorrect handling of the battery may cause heat excessive
generation, bursting, ignition, liquid leakage or deformation,
and lead to injury, fire or failures and malfunctions of facilities
and other equipment.
• Before modifying or disrupting the program in operation or
running the PLC, carefully read through this manual and the
associated manuals and ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the
memory cassette. If the memory cassette is attached or
detached while the PLC's power is on, the data in the memory
may be destroyed, or the memory cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric distributor.
• Turn off the power to the PLC before connecting or disconnecting
any extension cable.
Failure to do so may cause equipment failures or malfunctions.
• Turn off the power to the PLC before attaching or detaching the
following devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, Display module, expansion boards, and
special adapters
- Connector conversion adapter, extension blocks, and FX
Series terminal blocks
- Battery and memory cassette
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company
for the environmentally safe recycling and disposal of your
device.
When disposing of batteries, separate them from other waste
according to local regulations.
(For details of the Battery Directive in EU countries, refer to
FX
Series User's Manual - Hardware Edition.)
3G
TRANSPORT AND
STORAGE
PRECAUTIONS
• When transporting the FX
Series PLC incorporating the
3G
optional battery, turn on the PLC before shipment, confirm that
the battery mode is set using a parameter and the ALM LED is
OFF, and check the battery life.
If the PLC is transported with the ALM LED on or the battery
exhausted, the battery-backed data may be unstable during
transportation.
• The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 2.1. Failure to do
so may cause failures in the PLC.
After transportation, verify the operations of the PLC.
• When
transporting
lithium
batteries,
follow
required
transportation regulations.
(For details of the regulated products, refer to FX
Series
3G
User's Manual - Hardware Edition.)
Compliance with EC directive(CE Marking )
This document does not guarantee that a mechanical system
including this product will comply with the following standards.
Compliance to EMC directive and LVD directive of the entire
mechanical system should be checked by the user / manufacturer.
For more details please contact the local Mitsubishi Electric sales
site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Electromagnetic Compatibility (2004/108/EC) when
used as directed by the appropriate documentation.
Attention
• This product is designed for use in industrial applications.
• Manufactured by:
Mitsubishi Electric Corporation
2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan
• Manufactured at:
Mitsubishi Electric Corporation Himeji Works
840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan
• Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany.
Type :
Programmable Controller (Open Type Equipment)
Models :
MELSEC FX
series manufactured
3G
from June 1st, 2005
FX
-232ADP
FX
-485ADP
3U
3U
FX
-4AD-ADP
FX
-4DA-ADP
3U
3U
FX
-4AD-PT-ADP FX
-4AD-TC-ADP
3U
3U
from April 1st, 2007
FX
-232ADP-MB
FX
-485ADP-MB
3U
3U
from December 1st, 2007 FX
-4AD-PTW-ADP
3U
FX
-4AD-PNK-ADP
3U
from November 1st, 2008 FX
-
MT/ES(-A)
3G
Where
indicates:14,24,40,60
FX
-232-BD
FX
-422-BD
3G
3G
FX
-485-BD
3G
FX
-EEPROM-32L
3G
FX
-CNV-ADP
3G
FX
-2AD-BD
FX
-1DA-BD
3G
3G
FX
-8AV-BD
FX
-5DM
3G
3G
from December 1st, 2008 FX
-
MR/ES(-A)
3G
Where
indicates:14,24,40,60
from March 1st, 2009
FX
-
MT/ESS
3G
Where
indicates:14,24,40,60
from June 1st, 2009
FX
-3A-ADP
3U
from December 1st, 2009 FX
-
MR/DS
FX
-
MT/DS
3G
3G
FX
-
MT/DSS
3G
Where
indicates:14,24,40,60
Standard
Remark
EN61131-2:2003
Compliance with all relevant aspects
Programmable controllers
of the standard.
- Equipment
EMI
• Radiated Emissions
requirements and tests
• Conducted Emissions
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field

Advertisement

loading

Summary of Contents for Mitsubishi Electric FX3U-232ADP

  • Page 1 / manufacturer. Standard Remark read it whenever necessary. Always forward it to the end user. For more details please contact the local Mitsubishi Electric sales • Turn off the power to the PLC before attaching or detaching the Registration site.
  • Page 2 - General requirements • High-energy surge For the necessary product manuals or documents, consult with the EN61131-2:1994 The equipment has been assessed Mitsubishi Electric dealer from where you purchase your product. [10] • Voltage drops and interruptions [11] /A11:1996 as a component for fitting in a •...
  • Page 3 External dimensions and weight Name Item Specification INSTALLATION Operation status display LEDs PRECAUTIONS Class D grounding (grounding resistance: 100Ω or → For the input/output extension units/blocks, refer to FX Series User's Manual - Hardware Edition. Grounding less) <Common grounding with a heavy electrical Green On while power is on the PLC.
  • Page 4: Power Supply/Input/Output Specifications And Examples Of External Wiring

    Installation location Procedures for installing to and detaching from 2.4.2 Installation Notes DIN rail Install the PLC in an environment conforming to the generic • Simultaneously turn on and off the power supplies of the main 1) Make mounting holes in the specifications (section 2.1), installation precautions and notes.
  • Page 5 Wiring Power supply specifications and example of 3.2.2 Example of external wiring (AC power type) Grounding external wiring 100 to 240V AC power is supplied to the main unit and input/output This section explains the wiring of the terminal type. Ground the PLC as stated below.
  • Page 6 3.4.3 Examples of input wiring [DC power type] 3.4.4 Instructions for connecting input devices 3.4.6 Examples of 100V AC input wiring Item Specification As for the details of Instructions for connecting input devices, refer to Input response time Approx. 10ms 1.Sink input type 2.Source input type Fuse...
  • Page 7 Transistor output specifications and example of *3 The total load current of resistance loads per common terminal 3.5.3 Example of relay output wiring Item Specification should be the following value or less. external wiring Y000, 5μs or less/10mA or more - 1 output point/common terminal : 2A Y001 (5 to 24V DC)
  • Page 8: Terminal Block Layouts

    Series User's Manual - Hardware Edition. This manual confers no industrial property rights or any rights of any other kind, COM0 COM1 nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 3.7.2 External Wiring of Triac Output held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

This manual is also suitable for:

Fx3u-4ad-adpFx3u-485adpFx3u-4da-adpX3u-4ad-pt-adpFx3u-4ad-tc-adpFx3u-485adp-mb ... Show all