Download Print this page

VASTEX F-100 Assembly And Operating Instructions Manual page 5

Flash

Advertisement

Assembly Instructions Cont.
9) While firmly supporting the heater head, loosen
the locking knob and adjust the position of the heat-
er to 2-3" (5-10 centimeters) above the pallet.
10) Adjust the flash head parallel to the pallet. Use
a 9/16" wrench to turn in or out the flash head
leveling bolt.
Electrical Requirements
Models:
Plugs and receptacles listed below are for domestic
(USA) models.
International models are supplied with the
appropriate powercords.
F-100
120Volts, 12.5Amps, 1.65KW
Nema Plug 5-15P
Requires dedicated 15 amp circuit with a good
quality 5-15R receptacle.
F-100-240
240Volts, 6.3 Amps, 1.65KW
Nema Plug 6-15P
Requires good quality 6-15R receptacle.
F-1000
120Volts, 15Amps, 1.95 KW
Nema Plug 5-20P
Requires dedicated 20 amp circuit with a good
quality 5-20R receptacle.
F-1000-240
240Volts, 7.5Amps, 1.95 KW
Nema Plug 6-15P
Requires good quality 6-15R receptacle.
Receptacle Configurations USA Versions
5-15R
5-20R
!
6-15R
Controls
Models:
F100, F-100-240
-Power Switch
Turns on heater
-Heat On Light
This RED light will illuminate when the main power
switch is on.
Models:
F-1000, F-1000-240
-Heat Controller
The control has positions LO-2-3-4-5-6 and HI. The
controller turns the power to the heater on and off to
vary the temperature. The higher the number on the
control the longer the on cycle and shorter the off
cycle is. The "HI" position keeps the power on con-
stantly.
-Heat On Light
This RED light is wired to the controller. It will illu-
minate when the control is turned on, even if the
controller has failed.
Heater surfaces are very HOT.
Do Not leave Flash Unit turned on and unattended.
Do Not allow Flash Unit to dwell over the pallet for
extended periods of time or damage to pallet top
will result.
Heating Operation
Startup: Check that power switch or heat control is
turned off. Plug in the flash unit. Switch on breaker.
Turn on power switch or heat control to "HI". Allow
heater to reach full temperature, approx. 20 min.
Shutdown: Turn off power switch or heat control.
Switch off circuit breaker. Unplug flash unit.
Operation: The FLASH will effectively flash dry
all types of plastisols and thermoset inks. Set the
control to position 5 and a distance of 2-3" from the
face of the heater to the surface of the garment. The
normal dwell time under the heater is the time you
spend printing another garment. Nevertheless, 8-12
seconds is the time needed to effectively "skin-
over" the ink deposit. Adjust the heat control and/or
distance from the pallet to the heater to achieve
proper cure.
5

Advertisement

loading

This manual is also suitable for:

F-1000F-1000-240F-100-240