  • Page 1 INSTALLER’S & OWNER’S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Designed For Basement and Crawlspace Dehumidification www.basementsystems.com © Copyright Basement Systems, Inc. TS-311b...
  • Page 2: Table Of Contents

    SANIDRY CSB INSTALLER'S AND OWNER'S MANUAL Table of Contents Read and Save These Instructions Precautions ................1 WARNING! — This symbol means important 1. Intended Application ..............2 instructions. Failure to heed them can result in serious 2. Registrations .................2 injury or death. 3.
  • Page 3: Unit Assembly

    SANIDRY CSB INSTALLER'S AND OWNER'S MANUAL 4. Unit Assembly 5. Installation 4.1 Installing Feet (Optional) 5.1 Location Included with your SaniDry The SaniDry CSB can be installed in a variety oflocations to meet CSB are four leveling feet. It is the owner’s needs, but should beinstalled directly in the area to be important to level the unit for dehumidified.
  • Page 4: Electrical Requirements

    SANIDRY CSB INSTALLER'S AND OWNER'S MANUAL 5.2 Electrical Requirements The SaniDry CSB plugs into a common grounded outlet on a 15- Amp circuit. While operating, it draws less than 7 amps @ 80°F, 60% RH and less than 6 amps @ 75°F, 50% RH. Use of a ground fault circuit interrupter (GFCI) protected circuit is recommended.
  • Page 5: Maintenance

    See cleaning instructions below. For replacement filters The SaniDry CSB uses a refrigeration system similar to an air call your local Basement Systems dealer. conditioner’s to remove heat and moisture from incoming air and add heat to the air that is discharged. Hot, high pressure refrigerant The 1/4"...
  • Page 6: Troubleshooting

    SANIDRY CSB INSTALLER'S AND OWNER'S MANUAL Evaporator coil frosted continuously, low dehumidifying capacity. gas is routed from the compressor to the condenser coil. The refrigerant is cooled and condensed by giving up its heat to the 1 Dirty air filter or air flow restricted. air that is discharged from the dehumidifier.
  • Page 7: Warranty

    Product by a Customer. For the purpose of warranty coverage hereunder, the Customer must present forms this limited warranty, Basement Systems, its Dealers and other of invoices evidencing proof of purchase of a Product. If such representatives shall be considered authorized resellers of the invoices do not clearly indicate the date of initial purchase by Product.
  • Page 8 60 Silvermine Road may be reproduced or transmitted in any form or by any means, electronic or mechanical, Seymour, Connecticut 06483 for any purpose, without the express written permission of Basement Systems. Web: www.basementsystems.com 1-800-640-1500 © 2008 Basement Systems, Inc. All rights reserved.