Magnetic Float Switch M 1 (K) Alarm Contactor M 1 for AS 0, 2, 4, 5, AS W4, AS W8 M 1 K for AS 1-M and washing machine interrupter GEWAS 191 AN GL Installation/Operating Manual...
Page 2
Legal information/Copyright Installation/Operating Manual M 1 (K) Alarm Contactor Original operating manual All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent.
Waste water lifting unit Device for collecting and automatically lifting faecal-free waste water above the flood level M 1 (K) Alarm Contactor 4 of 20...
The serial number uniquely describes the system and is used as identification in all further business processes. In the event of damage, immediately contact your nearest KSB service centre to maintain the right to claim under warranty. 1.2 Target group This operating manual is aimed at the target group of trained and qualified specialist technical personnel.
All personnel involved must be fully qualified to transport, install, operate, maintain and inspect the machinery this manual refers to. The responsibilities, competence and supervision of all personnel involved in installation, operation, maintenance and inspection must be clearly defined by the operator. M 1 (K) Alarm Contactor 6 of 20...
In addition to the safety information contained in this manual and the intended use, the following safety regulations shall be complied with: ▪ Accident prevention, health and safety regulations ▪ Explosion protection regulations ▪ Safety regulations for handling hazardous substances ▪ Applicable standards and laws M 1 (K) Alarm Contactor 7 of 20...
1. On transfer of goods, check each packaging unit for damage. 2. In the event of in-transit damage, assess the exact damage, document it and notify KSB or the supplying dealer (as applicable) and the insurer about the damage in writing immediately.
Ama-Drainer-Box is too high. M 1 K alarm contactor The M 1 K alarm contactor is a float switch that responds when the water level in the collecting tank of the Ama-Drainer-Box is too high by...
Immersion time 7 days Initial function Circuit closed in upper float position (NO contact) Category of use AC-21A and DC-21A to DIN VDE 0660 T 107 IEC 947-3-1, EN 60 947-3-1 NOTE Always observe contact protection for inductive loads! M 1 (K) Alarm Contactor 10 of 20...
▷ Operate the control unit in flood-proof rooms only. 5.2 Installation in Ama-Drainer-Box Mini 732.01 550.02 550.01 81-45 Fig. 2: Fitting the bracket 550.01 Disc, Ø 21/7 mm 550.02 Disc, Ø 19/8.5 mm Pump 732.01 Bracket M 16 cable gland 81-45 Float switch M 1 (K) Alarm Contactor 11 of 20...
Keep the cable length inside the tank as short as possible. 81-45 81-45 Fig. 4: Installation drawing of M 1 (K) alarm contactor in Ama-Drainer-Box Mini 5.3 Installation in Ama-Drainer-Box 1U/1B - single-pump units Fasten clamp 733 to bracket 732.02 using cheese head screw 900, disc 550, and hexagon nut 920.
▷ Observe regulations IEC 60364 (DIN VDE 0100). M 1 alarm contactor Please refer to the wiring diagram. (ð Section 9.1, Page 18) NOTE Only KSB alarm switchgear AS 0, AS 2, AS 4, or AS 5 may be connected to the alarm contactor. M 1 K alarm contactor Connect M 1 K alarm contactor to the connector on the underside of the control...
▪ The information provided in the operating manual for alarm switchgear AS 0, AS 1-M, AS 2, AS 4, AS 5, and the washing machine interrupter is complied with. ▪ M 1 alarm contactor and alarm switchgear AS 0, AS 2, AS 4, AS 5, AS W4 or AS W8 have been connected in accordance with the wiring diagrams.
Operating reliability will be improved if proper functioning of the contactor is checked and verified at regular intervals. The contactor should be checked for deposits every 3 months and cleaned whenever necessary. M 1 (K) Alarm Contactor 16 of 20...
Reed contact defective Carry out continuity check on alarm contactor with an ohmmeter; consult KSB service, if necessary. ✘ ✘ Float blocked by dirt, fibres, or fluff. Clean float and sensor tube. M 1 (K) Alarm Contactor 17 of 20...
9.1 Wiring diagrams M 1 alarm contactor to alarm switchgear AS 0, AS 2, AS 4, AS W4, AS W8 AS 0, AS 2, AS 4, AS W4, AS W8 Fig. 8: Wiring diagram for M 1 alarm contactor to alarm switchgear AS 0, AS 2, AS 4, AS W4, AS W8 White (WH) Brown (BN) M 1 alarm contactor to alarm switchgear AS 5...
Index Index Commissioning/start-up 15 Faults Trouble-shooting 17 Other applicable documents 5 Safety awareness 7 Transport 8 M 1 (K) Alarm Contactor 19 of 20...