Page 2
Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in materials, workmanship, and performance for a period of one year from date of shipment from RKI Instruments, Inc. Any parts found defective within that period will be repaired or replaced, at our option, free of charge.
WARNING: When using the 35-3001-NS-03, you must follow the instructions and warnings in this manual to assure proper and safe operation of the 35-3001-NS-03 and to minimize the risk of personal injury. Be sure to maintain and periodically calibrate the 35-3001-NS-03 as described in this manual.
Figure 1: Sample-Draw Pump Component Location External Components This section describes the sample-draw pump’s external components. Housing The sample-draw pump’s fiberglass housing is weather- and corrosion-resistant. It is suitable for installation where general purpose equipment is in use. 35-3001-NS-03 Sample-Draw Pump • 5...
The pump connector is the two-point connector below the oxygen terminal strip in the upper right corner of the main circuit board. Use the pump connector to connect the pump to the main circuit board. 6 • 35-3001-NS-03 Sample-Draw Pump...
Page 7
The pump is mounted to the right side of the main circuit board. The pump pulls the gas sample into the sample-draw pump. The pump operates on 24 VAC, which is generated from the 24 VDC supplied by the power source. 35-3001-NS-03 Sample-Draw Pump • 7...
Are the flowmeter and status LEDs visible? 6.50 Ø .30 x .50 (4X) M OUNTING 1.13 4.00 Pilot Fail Sample Drawing Gas Detector 8.88 8.50 35-3001 www.rkiinstruments.com 4.50 NOTE: Housing is 4.3 inches deep Figure 3: Outline and Mounting Dimensions 8 • 35-3001-NS-03 Sample-Draw Pump...
Push 1/4” O.D. rigid polypropylene or rigid Teflon sample tubing into the fitting until it stops. Flexible polyurethane tubing may be used with an appropriate insert. RKI Instruments, Inc. recommends using either 1/4” O.D. x 1/8” I.D. or 1/4” O.D. x 0.170” I.D. tubing based on your length requirements.
Push 1/4” O.D. rigid polypropylene or rigid Teflon sample tubing into the fitting until it stops. Flexible polyurethane tubing may be used with an appropriate insert. RKI Instruments, Inc. recommends using either 1/4” O.D. x 1/8” I.D. or 1/4” O.D. x 0.170” I.D. tubing based on your length requirements.
Page 11
LO W 110 VDC 0.6A AMP 1 AMP 2 F L O W + 24 VDC - (DC Ground) Power Contact Resistive Monitoring Load Device Device Figure 5: Wiring the Sample-Draw Pump to a Power Source 35-3001-NS-03 Sample-Draw Pump • 11...
3.0 SCFH, a flow rate of 2.0 SCFH still provides good sensor response at the flow through adapter. RKI Instruments, Inc. does not recommend a flow rate of lower than 2.0 SCFH. Turn the valve’s knob counterclockwise to increase the flow and clockwise to decrease the flow.
The sample-draw pump is malfunctioning. Recommended action At the sample-draw pump, set the correct flow rate with the flow control valve. If you cannot set the correct flow rate, check the sample lines for obstructions or kinks. 35-3001-NS-03 Sample-Draw Pump • 13...
If the fail condition continues, contact RKI Instruments, Inc. for further instruction. Slow or No Response/Difficult or Unable to Calibrate Symptoms • The detector head that the pump is drawing sample through responds slowly or does not respond. • Unable to accurately set the zero or response reading during calibration.