Racepak 500-SW-PNL8 Manual

Smartwire switch panel

Advertisement

Quick Links

Switch Panel Name:
VNet ID:
Logger Sample Rate
Type:
Serial Number:
Firmware Version:
Switch Bus Terminator Resistor
NOTES:
 Requires DataLinkII 3.8.5 or greater
 Requires a SmartWire Extension cable #580-CA-BN5P-xxx for connection to SmartWire or currently
installed switch bus devices. xxx refers to the length, available in 6", 12", 18", 24", 36", 48", 60", 72",
84", 96", 108", 120"

Description:

The Switch Panel contains 1 momentary push button, 7 two-way toggle switches, and 8 status LEDs. This
device allows a total of 8 inputs into the SmartWire system which can be utilized to operate any of the outputs
on the SmartWire System.
Switch Names: Name of each switch. Can be changed to match the function of each switch. It is
recommended to start the name with a reference to the type (ex: Switch Panel Input #2 for Ignition = "SP#2
Ignition"). Name must start with a letter. Keep in mind each switch can have multiple functions/outputs due
its ability to be used in multiple output control logic windows.
Example; one switch can turn on multiple items (outputs) such as fuel pumps, ignition system
together along with other outputs of the SmartWire with one flip of the switch. This along with
other logic and Time Delay features can be used to stagger outputs with other inputs/outputs.
Status IDs: The Status ID represents action of the LED lights above the toggle switches. The Status ID can be
used to simply monitor the status of the toggle switch (Switch On x0) or to indicate the status of any selected
output by selecting the channel in the pull-down menu desired to monitor. The Status ID can monitor any
selected output channel, regardless of the output channel the switch actually controls.

Hardware Installation

NOTE: Once installed, the Terminating Resistor settings must be programmed for each item on the Switch
Port in the DataLinkII software. By Default, all items on the Switch Bus are shipped with the Switch Bus
Terminating Resistor set to ON. If more than one device is connected to the Switch Port on the SmartWire
main unit, only the last items in line must have the Switch Bus Terminating Resistor set to ON, all other
devices between last device and the SmartWire main unit, must be set to OFF.
NOTE: Avoid mounting near heat sources and high voltage ignition wires. The Switch Panel must be
mounted in a location the temperature does not exceed 185 degrees or the panel will be damaged.
SmartWire Switch Panel
Part number: 500-SW-PNL8

Default Module Configuration Setup:

SP1 Inputs
Switches Panel #1 x18C
20
TOGGLE_SWITCH_PANEL
2
ON

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 500-SW-PNL8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Racepak 500-SW-PNL8

  • Page 1: Hardware Installation

    SmartWire Switch Panel Part number: 500-SW-PNL8 Default Module Configuration Setup: Switch Panel Name: SP1 Inputs VNet ID: Switches Panel #1 x18C Logger Sample Rate Type: TOGGLE_SWITCH_PANEL Serial Number: Firmware Version: Switch Bus Terminator Resistor NOTES:  Requires DataLinkII 3.8.5 or greater ...
  • Page 2 Currently no items connected to the Switch port on the SmartWire main unit: Using the appropriate length cable (#580-CA-BN5P-xxx), connect one end of the cable to the Switch port on the SmartWire main unit, the other end can connect to either port on the Switch Panel. SmartWire Main Unit Switch Panel Connect to Switch Port...
  • Page 3 Software Programming SmartWire used as Stand Alone (with SmartWire used with V-Net sensors V-Net sensors, No Data Recorder) and Data Recorder 1. Connect PC to SmartWire unit using the USB 1. Connect PC to data recorder using the programming cable supplied with SmartWire programming cable supplied with data unit system.
  • Page 4  Vnet ID: V-Net ID for the Switch Panel. Change only if more than one Switch Panel is connected to one SmartWire main unit. Default=SmartWire 1 Switches x190  Logger Sample Rate: Logging sample rate of this channels when used with a Racepak data logger. Default=20 ...
  • Page 5  Status IDs: The Status ID represents action of the LED lights above the toggle switches. The Status ID can be used to simply monitor the status of the toggle switch (Switch On x0) or to indicate the status of any selected output by selecting the channel in the pull-down menu desired to monitor. The Status ID can monitor any selected output channel, regardless of the output channel the switch actually controls.

Table of Contents