Advertisement

Quick Links

DSO
DSO
DSO
DSO Nano
I Product Intro............................................................................................................2
II General Safety Rules ............................................................................................ 2
III Major Functions .....................................................................................................2
IV Operation Precautions ...............................................................................................3
V General Inspection.................................................................................................... 3
VI Functional Inspections.............................................................................................................................. 3
VII Battery Recharging Instruction..................................................................................3
VII Firmware Upgrades .................................................................................................3
IX Product Familiarization........................................................................................... 5
1. Interface and Buttons..........................................................................................5
2. Screen............................................................................................................5
X Measurement Operation Instruction............................................................................6
1. Parameter Area Intro.............................................................................................6
2. Measurement Area Intro.................................................................................6
3. Specific Parameters Intro.................................................................................6
XI Application Examples...........................................................................................9
1. Example One: Measure Simple Signal.....................................................................11
2. Example Two: Measure with Cursor........................................................................12
3. Example Three: Save Waveform Image.....................................................................13
4. Example Four: Acquire Single Signal........................................................................14
5. Example Five: Compare Waveform Signals...............................................................15
Nano
V3
User
User' ' ' ' s s s s Manual
Nano
V3
User
Nano V3
V3 User
Contents
Contents
Contents
Contents
Manual
Manual
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DSO Nano V3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seeed Technology DSO Nano V3

  • Page 1: Table Of Contents

    Nano User User’ ’ ’ ’ s s s s Manual Manual Nano User Manual DSO Nano Nano V3 V3 User Manual Contents Contents Contents Contents I Product Intro………………………………………………………………………………………..…….2 II General Safety Rules ……………………………………………………………………………….. 2 III Major Functions ………………………………………………………………………………………..2 IV Operation Precautions …………………………………………………………………………………..3 V General Inspection……………………………………………………………………………………….
  • Page 2: I Product Intro

    I Product Product Product Intro Intro Product Intro Intro DSO Nano pocket size oscilloscope is a compatible 32bit digital storage oscilloscope. Based on ARM -M3, it’s equipped with 320*240 color display, SD card, USB port and recharging function. It’s compact, simple to operate;...
  • Page 3: Operation Precautions

    IV Operation Operation Operation Precautions Precautions Operation Precautions Precautions ▌Temperature: Working condition:+0℃ to +500℃ Non-working condition:-20℃ to +60℃: ▌Humidity: Working condition:High temperature:40°C - 50°C,0%-60%RH Working condition:Low temperature:0°C - 40°C,10%-90%RH Non-working condition:High temperature:40°C- 60°C,5%-60%RH Non-working condition:Low temperature:0°C - 40°C,5%-90%RH V General General Inspection General...
  • Page 4 Copy file from PC to the virtual USB disk After extension changes from “hex” to “rdy”, it’s upgraded. IX Product Product Product Familiarization Familiarization Product Familiarization Familiarization 1. 1. 1. 1. Interface Interface Interface Interface & & & & Buttons Buttons Buttons Buttons...
  • Page 5: Product Familiarization

    2. 2. 2. 2. Screen Screen Screen Screen screen display display is is is is depicted depicted depicted as as as as below: below: The screen screen screen display display depicted below: below: Parameter Area Measurement Area Parameter Area Display the position of current waveform...
  • Page 6: Measurement Operation Instruction

    The table below shows the intro of button functions Button Function Run/Hold �|| Choose to save current parameter setting(long press) ▲ Upward selection ▼ Downward selection (left/decrease)change setting parameters ◄ (right/increase)change setting parameters ► Menu Choose to save current file(long press) NOTE:There are corresponding colors for items in Parameter Area and Measurement Area.
  • Page 7 Y Ranges Y-axis voltage per grid ProbeAtt Multiple FitRange Auto adjustment Y Offset Waveform adjusts up & down within the window CursorV1 Cursor V1:top limit of visible trigger level CursorV2 CursorV2:bottom limit of visible trigger level CursorTp Hide/ Display Measurement Cursor (2)Annotations of Xn Parameters TimeBase X-axis voltage per grid...
  • Page 8 ViewPosi Horizontal movement to view waveform SmplDpth Internal storage depth(1k~6k) CursorT1 Time measurement cursorT1 CursorT2 Time measurement cursorT2 CursorTp Hide/Display Measurement Cursor (3)Annotations of Tr parameters Choices of Triggering Mode SyncMode AUTO/NORM/SINGL/NONE/SCAN Automation/Normal/Singular/Slow Scan/Instant Scan TrigMode Rising edge/falling edge triggering mode Auto Fit Auto adjustment Threshol...
  • Page 9 Freq Signal Frequency Duty Dutyfactor Vrms Voltage Effective Value Vavg Average Value of Voltage Vp-p Peak-to-Peak Voltage Vmax Maximum Voltage Vmin Minimum Voltage (5)Annotations of Ex Parameters Ext Refn 2 waveforms operation (Inp is current waveform; D/Data is previously saved waveform) -Inp/Data/-Data/Inp+D/D-Inp/Inp-D...
  • Page 10 Ext Posi Display current waveform (6)Annotations of Fn Parameters Save Bmp Save bmp file (waveform image) to the built-in U disk Save Dat Save dat file to the built-in U disk Save Buf Save buf file (sampling buffering data) to built-in U disk Save Csv Save csv file (export sampling buffering data)to built-in U disk Load Dat...
  • Page 11: Application Examples

    (8)Annotations of Ca Parameters Cal Zero Calibration without voltage Oscilloscope Calibration:Press�|| CalRange Calibration with voltage Restore Master Reset XI Application Application Application Examples Examples Application Examples Examples 1. 1. 1. 1. Example Example Example One: One: Measure Measure Simple Simple Signal Signal Example One:...
  • Page 12: Example Two: Measure With Cursor

    signal parameters that need analysis, e.g. Freq(frequency), Duty(dutyfactor), Vpp(peak-to-peak voltage)etc., the measured value will be displayed at the lower right corner of the screen, as shown in the image below: 2. 2. 2. 2. Example Example Example Example Two Two: Measure Measure Measure Measure with...
  • Page 13: Example Three: Save Waveform Image

    (2)Measure peak-to-peak value of the signal source. Please operate according to following steps: �Use “▲” or “▼” to choose Yn items in Measurement Area �Press “OK” �Use “◄” or “►” to choose CursorV1 �Use “▲” or “▼” to adjust the position of CursorV1 to the crest �Use “◄”...
  • Page 14: Example Four: Acquire Single Signal

    image. 4. 4. 4. 4. Example Example Example Example Four: Four: Four: Four: Acquire Acquire Acquire Acquire Single Single Single Single Signal Signal Signal Signal It’s the superiority and feature of digital oscilloscope to easily aquire non-periodic signals like impulsion and sentus.
  • Page 15: Example Five: Compare Waveform Signals

    5 5 5 5 ..Example Example Example Five: Five: Compare Compare waveform waveform signals signals Example Five: Five: Compare Compare waveform waveform signals signals Please operate according to following steps: �Input standard signal waveform to the channel, chose Data in EX, and then choose Save Dat 01 to save the waveform, as shown in the image below.

This manual is also suitable for:

Nano v3

Table of Contents