    INTRODUCTION Thank you for purchasing a quality KOHLER product. To enjoy the full potential of your new ® product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. The following pages aim to provide comprehensive installation instructions, plus advice on how to care and maintain your product. We recommend that the unit is installed by a qualified plumber or engineer. General Read all of these instructions and retain this guide for later use. Pass on this guide in the event of change of ownership of the installation site. Follow all warnings, cautions and instructions contained in this guide. Remove all protective tape from the enclosure before installation. GENERAL INFORMATION Safety Information Care should be taken when drilling into walls and floors to avoid any hidden pipes or wires. We strongly recommend that all glass panels are moved by a minimum of two people and that any protective packaging along the glass edges is kept in place for as long as possible to prevent damage before installation. During installation we recommend additional help in lifting heavy doors and side panels. Wear protective footwear when lifting panels. Wear safety glasses when drilling. Wall Preparation T h e w a l l c h a n n e l s m u s t...
  • Page 4: Tools Required

    GUARANTEE For domestic installations, your enclosure has the benefit of our lifetime guarantee which starts from date of purchase. For non-domestic installations, we guarantee the product against any defect in materials or workmanship for a period of one year from the date of purchase. For terms and conditions refer to the back cover of this guide. Recommended Usage Domestic ü Light Commercial ü Heavy Commercial û Healthcare û TOOLS REQUIRED 6.0 mm 2.0 mm 3.0 mm 1180583-W2-B...
  • Page 5: Pack Contents

    PACK CONTENTS Pack 1 Pack 2 X 1 q X 1 q X 1 q X 1 q 1180583-W2-B...
  • Page 6: Installation

    INSTALLATION 9 mm ± 0 mm Note! Make sure that the walls have been tiled down to the tray. Height of Enclosure (mm) 1900 Min/Max Frame Adjustment Enclosure Size Minimum (mm) Maximum (mm) 900 x 900 1200 x 900 1200 1167 1197 (a) Install the shower tray in accordance with the manufacturer’s instructions. Caution! Make sure that the shower tray is level and that the walls are vertical and square.
  • Page 7 RH Panel Shown ± 0 mm 6 mm 9 mm (a) Position one of the panel wall channels. Using a spirit level make sure that it is upright. (b) Mark the position of the fixing holes, then remove the wall channel. (c) Drill with a 6 mm masonry bit (not supplied), and plug using the wall plugs (supplied with the door). (d) Position the wall-channel on the wall and install the fixing screws (supplied with door). (e) Fully tighten the fixing screws, making sure that the wall channel is upright. 1180583-W2-B...
  • Page 8 LH Panel Shown ± 0 mm 6 mm 9 mm (a) Position the second panel wall channel on the wall. Using a spirit level make sure that it is upright. (b) Mark the position of the fixing holes, then remove the wall channel. (c) Drill with a 6 mm masonry bit (not supplied), and plug using the wall plugs (supplied with the door). (d) Position the wall channel on the wall and install the fixing screws (supplied with the door). (e) Fully tighten the fixing screws, making sure that the wall channel is upright. 1180583-W2-B...
  • Page 9 (a) Install the side panels over the wall channels that had been secured to the wall earlier. (b) Adjust the side panels so that they are in the correct position. 1180583-W2-B...
  • Page 10 Side Panel Door Panel (a) Install the door in position. (b) Push the side panel and the door frame together until the extrusions engage and lock together. 1180583-W2-B...
  • Page 11 ± 0 mm (a) Centralise the door frame within the wall channels, making sure that the door frame is square. 1180583-W2-B...
  • Page 12 L & R 3.0 mm 90° (a) Using the 3.0 mm hexagonal wrench (supplied), turn through 90° in three locations to lock the door frame in position. Repeat this on the other wall channel. 1180583-W2-B...
  • Page 13 (a) Install the infill strip as shown above to both sides, working from top to bottom. (b) Refer to the door installation instructions to lock the door frame to the side panels in three positions on both sides. 1180583-W2-B...
  • Page 14 (a) Apply sealant in accordance with the sealant manufacturers instructions along the outside surfaces of the door frame only. (b) Allow the silicone sealant to cure for 24 hours before use. 1180583-W2-B...
  • Page 15 5 10 (a) Fit the covers to the top of the extrusions. (b) For adjustment of the doors, refer to the Installation and User guide packed with the door. 1180583-W2-B...
  • Page 16: General Maintenance

    MAINTENANCE General Maintenance Providing the shower enclosure has been correctly installed and is operated in accordance with the instructions contained in this guide, difficulties should not arise. If any maintenance is required then it must be carried out by a competent tradesperson to whom the maintenance instructions are provided. Before replacing any parts ensure the underlying cause of the malfunction has been resolved. Cleaning Warning! Many household cleaners contain abrasive and chemical substances and should not be used for cleaning painted, plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution and then wiped dry using a soft cloth. Care To preserve the beauty of your shower enclosure for many years, please observe the following care instructions: Rinse glass and frame with clear water after showering. Remove water droplets with a squeegee. Do not rub dry! To clean your shower hygienically and easily, we recommend the use of a biodegradable cleanser.
  • Page 17: Spare Parts

    SPARE PARTS LH Pent Panel 1781.459 Pent Panel Top Cap Pack 1781.380 Locking Mechanism Spare 1781.381 Infill Spare 1180583-W2-B...
  • Page 18 RH Pent Panel 1781.459 Pent Panel Top Cap Pack 1781.380 Locking Mechanism Spare 1781.381 Infill Spare 1180583-W2-B...
  • Page 19 NOTES 1180583-W2-B...
  • Page 20 To activate this guarantee, you must return your completed registration card with a copy of proof of purchase from an approved Kohler retailer within 30 days of purchase. Fax: 0844 571 7157 This guarantee is in addition to your statutory rights and is subject to conditions (see registration card).

Table of Contents