WARNING
Level indicator installation and using must be done outside from any magnetic field zone. Use non magnetic connection (Brass, Stainless
Steel or plastic). Any iron device must be installed at 10 cm minimum distance fare. Ensure chemical compliance between liquid and
level indicator. To get easy mounting and dismounting, a valve can be placed between tank and level indicator flange. Those valves may
be used, also, for liquid regulation to avoid strong float up movement (which may damage it). Inlet tank pressure, then in level indicator,
must not be over specified in technical features (6 bar as a maximum).
INTRODUCTION
Those level indicators allow instantaneous liquid level reading, even they are opaque.They are installed on tank side, by flanges.
Measurement on communicating vessels principle. The Float, equipped with magnet, moves bi-colours flaps which keep their positions
until the float is coming back. Their colours (red and yellow on black back side) ensure instantaneous and easy reading. Equipped with
graduated rule (in option) reading accuracy will be higher.
INSTRUCTIONS MANUAL
LEVEL INDICATORS
LEVEL INDICATORS
MAGTOP 801, 803, 806
19-03-2014
MES
560-06
560 M0 06 C
/1

Advertisement

loading

Summary of Contents for Bamo MAGTOP 801

  • Page 1 Level indicators MAGTOP 801, 803, 806 WARNING Level indicator installation and using must be done outside from any magnetic field zone. Use non magnetic connection (Brass, Stainless Steel or plastic). Any iron device must be installed at 10 cm minimum distance fare. Ensure chemical compliance between liquid and level indicator.
  • Page 2 1. MOUNTING Verify tank flanges compatibility with MAGTOP flanges. Install level indicator on tank side. Do not forget to set seals (not furnished). It is highly suggested to set insulation valves, between tank and level indicator, in order to be able to remove the float in case of jamming. Insert the float by removing union 7.

This manual is also suitable for:

Magtop 803Magtop 806